{"id":{"repo_id":"carleton","oai_identifier":"oai:carleton.scholaris.ca:20.500.14718/42017"},"canonical_url":"https://search.ndltd.org/etd/carleton/oai:carleton.scholaris.ca:20.500.14718/42017","repository":{"repo_id":"carleton","name":"Carleton University","base_url":"https://carleton.scholaris.ca/server/oai/request"},"display":{"title":"Postmastectomy radiation therapy for patients with tissue expanders","abstract":"Temporary breast tissue expanders contain a metal port that can vary in position throughout the course of radiation treatments. In this study, the magnitude and the dosimetric effect of the interfractional positional variations of the metal port was quantified. The robustness of the three most common external beam treatment techniques (tangential 3DCRT, VMAT and helical Tomotherapy) was evaluated against the measured positional errors. Results showed that interfractional positional errors were generally small, but errors larger than 1.5 cm were also observed. The interfractional positional variations arise from a combination of internal port errors and patient registration errors. Patient registration errors were shown to have larger dosimetric effect on target coverage and nearby organs than internal port errors. VMAT and Tomotherapy treatments are more robust when patient registration errors are minimized. The misalignment of the metal port during patient registration is acceptable when a more optimal anatomy match can be achieved.","abstract_html":"Temporary breast tissue expanders contain a metal port that can vary in position throughout the course of radiation treatments. In this study, the magnitude and the dosimetric effect of the interfractional positional variations of the metal port was quantified. The robustness of the three most common external beam treatment techniques (tangential 3DCRT, VMAT and helical Tomotherapy) was evaluated against the measured positional errors. Results showed that interfractional positional errors were generally small, but errors larger than 1.5 cm were also observed. The interfractional positional variations arise from a combination of internal port errors and patient registration errors. Patient registration errors were shown to have larger dosimetric effect on target coverage and nearby organs than internal port errors. VMAT and Tomotherapy treatments are more robust when patient registration errors are minimized. The misalignment of the metal port during patient registration is acceptable when a more optimal anatomy match can be achieved.","abstract_has_math":false,"creators":["Mayorov, Keren"],"institution":"Carleton University","degree_name":"Master of Science (M.Sc.)","degree_level":"Master's","degree_discipline":"Physics","degree_department":null,"school":null,"contributors":[],"advisors":[],"committee_chairs":[],"committee_members":[],"year":2020,"date_issued":"2020","date_published":"2020","updated_at":"2026-11-19T07:04:26Z","subjects":["Physics","Oncology","Radiation"],"languages":["en"],"rights":["Copyright © 2020 the author(s). Theses may be used for non-commercial research, educational, or related academic purposes only. Such uses include personal study, research, scholarship, and teaching. Theses may only be shared by linking to Carleton University Institutional Repository and no part may be used without proper attribution to the author. No part may be used for commercial purposes directly or indirectly via a for-profit platform; no adaptation or derivative works are permitted without consent from the copyright owner."],"rights_urls":[],"identifier_entries":[{"key":"dc:identifier.doi","label":"DOI","values":["10.22215/etd/2020-14380"],"render_values":[{"text":"10.22215/etd/2020-14380","href":"https://doi.org/10.22215/etd/2020-14380","code":true}]}],"person_identifier_entries":[]},"links":{"outbound_url":"https://hdl.handle.net/20.500.14718/42017","outbound_label":"Handle","outbound_source":"dc:identifier.uri","record_url":"https://hdl.handle.net/20.500.14718/42017","record_label":"Repository record","record_kind":"handle","record_source":"dc:identifier.uri","download_url":null,"download_label":null,"download_source":null,"access_status":null,"embargo_until":null,"access_note":null},"source_record":{"url":"https://carleton.scholaris.ca/server/oai/request?verb=GetRecord&metadataPrefix=dim&identifier=oai%3Acarleton.scholaris.ca%3A20.500.14718%2F42017","prefix":"dim"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:creator","label":"Author","values":["Mayorov, Keren"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2025-04-08T20:29:48Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2025-04-08T20:29:48Z"]},{"key":"dc:date.issued","label":"Date","values":["2020"]},{"key":"dc:publisher","label":"Institution","values":["Carleton University"]},{"key":"dc:type","label":"Dc Type","values":["thesis"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Physics"]},{"key":"thesis:degree_level","label":"Degree Level","values":["Master's"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Master of Science (M.Sc.)"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject.lcsh","label":"Dc Subject Lcsh","values":["Physics","Oncology","Radiation"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language.iso","label":"Language (ISO)","values":["en"]},{"key":"dc:rights","label":"Dc Rights","values":["Copyright © 2020 the author(s). Theses may be used for non-commercial research, educational, or related academic purposes only. Such uses include personal study, research, scholarship, and teaching. Theses may only be shared by linking to Carleton University Institutional Repository and no part may be used without proper attribution to the author. No part may be used for commercial purposes directly or indirectly via a for-profit platform; no adaptation or derivative works are permitted without consent from the copyright owner."]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.doi","label":"DOI","values":["10.22215/etd/2020-14380"]},{"key":"dc:identifier.uri","label":"Identifier URI","values":["https://hdl.handle.net/20.500.14718/42017"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["Temporary breast tissue expanders contain a metal port that can vary in position throughout the course of radiation treatments. In this study, the magnitude and the dosimetric effect of the interfractional positional variations of the metal port was quantified. The robustness of the three most common external beam treatment techniques (tangential 3DCRT, VMAT and helical Tomotherapy) was evaluated against the measured positional errors. Results showed that interfractional positional errors were generally small, but errors larger than 1.5 cm were also observed. The interfractional positional variations arise from a combination of internal port errors and patient registration errors. Patient registration errors were shown to have larger dosimetric effect on target coverage and nearby organs than internal port errors. VMAT and Tomotherapy treatments are more robust when patient registration errors are minimized. The misalignment of the metal port during patient registration is acceptable when a more optimal anatomy match can be achieved."]},{"key":"dc:title","label":"Title","values":["Postmastectomy radiation therapy for patients with tissue expanders"]},{"key":"local:lac.licence","label":"Local Lac Licence","values":["true"]},{"key":"others:access_status","label":"Others Access Status","values":["open.access"]}]}],"canonical_facts":{"dc:creator":["Mayorov, Keren"],"dc:date.accessioned":["2025-04-08T20:29:48Z"],"dc:date.available":["2025-04-08T20:29:48Z"],"dc:date.issued":["2020"],"dc:description.abstract":["Temporary breast tissue expanders contain a metal port that can vary in position throughout the course of radiation treatments. In this study, the magnitude and the dosimetric effect of the interfractional positional variations of the metal port was quantified. The robustness of the three most common external beam treatment techniques (tangential 3DCRT, VMAT and helical Tomotherapy) was evaluated against the measured positional errors. Results showed that interfractional positional errors were generally small, but errors larger than 1.5 cm were also observed. The interfractional positional variations arise from a combination of internal port errors and patient registration errors. Patient registration errors were shown to have larger dosimetric effect on target coverage and nearby organs than internal port errors. VMAT and Tomotherapy treatments are more robust when patient registration errors are minimized. The misalignment of the metal port during patient registration is acceptable when a more optimal anatomy match can be achieved."],"dc:identifier.doi":["10.22215/etd/2020-14380"],"dc:identifier.uri":["https://hdl.handle.net/20.500.14718/42017"],"dc:language.iso":["en"],"dc:publisher":["Carleton University"],"dc:rights":["Copyright © 2020 the author(s). Theses may be used for non-commercial research, educational, or related academic purposes only. Such uses include personal study, research, scholarship, and teaching. Theses may only be shared by linking to Carleton University Institutional Repository and no part may be used without proper attribution to the author. No part may be used for commercial purposes directly or indirectly via a for-profit platform; no adaptation or derivative works are permitted without consent from the copyright owner."],"dc:subject.lcsh":["Physics","Oncology","Radiation"],"dc:title":["Postmastectomy radiation therapy for patients with tissue expanders"],"dc:type":["thesis"],"local:lac.licence":["true"],"others:access_status":["open.access"],"thesis:degree_discipline":["Physics"],"thesis:degree_level":["Master's"],"thesis:degree_name":["Master of Science (M.Sc.)"]},"updated_at":"2026-11-19T07:04:26Z"}