{"id":{"repo_id":"carleton","oai_identifier":"oai:carleton.scholaris.ca:20.500.14718/42119"},"canonical_url":"https://search.ndltd.org/etd/carleton/oai:carleton.scholaris.ca:20.500.14718/42119","repository":{"repo_id":"carleton","name":"Carleton University","base_url":"https://carleton.scholaris.ca/server/oai/request"},"display":{"title":"Development of a Hygrothermal Model Validation Methodology Using a Two-Storey Guarded Hot Box","abstract":"Hygrothermal performance is an essential component of building performance, with heat, air, and moisture transport through the building envelope as a key element. Current modelling programs such as Delphin can be used to simulate hygrothermal performance of building envelopes but require physical data for validation, either from in-situ or controlled laboratory experiments. This allows for confidence in the use of hygrothermal models. This thesis used a two-storey guarded hot box (GHB) apparatus to develop a testing sequence that provided sufficient data for confidence in validation. Two lightweight vertical walls were tested in the GHB, each for 1200 hours. The model validation was completed using graphical and statistical analysis. After an initial validation, model adjustments were completed based on the sensitivity of various model parameters. The improved models resulted in excellent agreement between the experimental and modelled performance.","abstract_html":"Hygrothermal performance is an essential component of building performance, with heat, air, and moisture transport through the building envelope as a key element. Current modelling programs such as Delphin can be used to simulate hygrothermal performance of building envelopes but require physical data for validation, either from in-situ or controlled laboratory experiments. This allows for confidence in the use of hygrothermal models. This thesis used a two-storey guarded hot box (GHB) apparatus to develop a testing sequence that provided sufficient data for confidence in validation. Two lightweight vertical walls were tested in the GHB, each for 1200 hours. The model validation was completed using graphical and statistical analysis. After an initial validation, model adjustments were completed based on the sensitivity of various model parameters. The improved models resulted in excellent agreement between the experimental and modelled performance.","abstract_has_math":false,"creators":["Hilbrecht, Robin Frances"],"institution":"Carleton University","degree_name":"Master of Applied Science (M.App.Sc.)","degree_level":"Master's","degree_discipline":"Engineering, Sustainable Energy","degree_department":null,"school":null,"contributors":[],"advisors":[],"committee_chairs":[],"committee_members":[],"year":2024,"date_issued":"2024","date_published":"2024","updated_at":"2026-11-19T07:05:39Z","subjects":["Civil engineering","Mechanical engineering","Engineering"],"languages":["en"],"rights":["Copyright © 2024 the author(s). Theses may be used for non-commercial research, educational, or related academic purposes only. Such uses include personal study, distribution to students, research and scholarship. Theses may only be shared by linking to the Carleton University Institutional Repository and no part may be copied without proper attribution to the author; no part may be used for commercial purposes directly or indirectly via a for-profit platform; no adaptation or derivative works are permitted without consent from the copyright owner."],"rights_urls":[],"identifier_entries":[{"key":"dc:identifier.doi","label":"DOI","values":["10.22215/etd/2024-16150"],"render_values":[{"text":"10.22215/etd/2024-16150","href":"https://doi.org/10.22215/etd/2024-16150","code":true}]}],"person_identifier_entries":[]},"links":{"outbound_url":"https://hdl.handle.net/20.500.14718/42119","outbound_label":"Handle","outbound_source":"dc:identifier.uri","record_url":"https://hdl.handle.net/20.500.14718/42119","record_label":"Repository record","record_kind":"handle","record_source":"dc:identifier.uri","download_url":null,"download_label":null,"download_source":null,"access_status":null,"embargo_until":null,"access_note":null},"source_record":{"url":"https://carleton.scholaris.ca/server/oai/request?verb=GetRecord&metadataPrefix=dim&identifier=oai%3Acarleton.scholaris.ca%3A20.500.14718%2F42119","prefix":"dim"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:creator","label":"Author","values":["Hilbrecht, Robin Frances"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2025-04-08T20:31:54Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2025-04-08T20:31:54Z"]},{"key":"dc:date.issued","label":"Date","values":["2024"]},{"key":"dc:publisher","label":"Institution","values":["Carleton University"]},{"key":"dc:type","label":"Dc Type","values":["thesis"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Engineering, Sustainable Energy"]},{"key":"thesis:degree_level","label":"Degree Level","values":["Master's"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Master of Applied Science (M.App.Sc.)"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject.lcsh","label":"Dc Subject Lcsh","values":["Civil engineering","Mechanical engineering","Engineering"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language.iso","label":"Language (ISO)","values":["en"]},{"key":"dc:rights","label":"Dc Rights","values":["Copyright © 2024 the author(s). Theses may be used for non-commercial research, educational, or related academic purposes only. Such uses include personal study, distribution to students, research and scholarship. Theses may only be shared by linking to the Carleton University Institutional Repository and no part may be copied without proper attribution to the author; no part may be used for commercial purposes directly or indirectly via a for-profit platform; no adaptation or derivative works are permitted without consent from the copyright owner."]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.doi","label":"DOI","values":["10.22215/etd/2024-16150"]},{"key":"dc:identifier.uri","label":"Identifier URI","values":["https://hdl.handle.net/20.500.14718/42119"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["Hygrothermal performance is an essential component of building performance, with heat, air, and moisture transport through the building envelope as a key element. Current modelling programs such as Delphin can be used to simulate hygrothermal performance of building envelopes but require physical data for validation, either from in-situ or controlled laboratory experiments. This allows for confidence in the use of hygrothermal models. This thesis used a two-storey guarded hot box (GHB) apparatus to develop a testing sequence that provided sufficient data for confidence in validation. Two lightweight vertical walls were tested in the GHB, each for 1200 hours. The model validation was completed using graphical and statistical analysis. After an initial validation, model adjustments were completed based on the sensitivity of various model parameters. The improved models resulted in excellent agreement between the experimental and modelled performance."]},{"key":"dc:title","label":"Title","values":["Development of a Hygrothermal Model Validation Methodology Using a Two-Storey Guarded Hot Box"]},{"key":"local:lac.licence","label":"Local Lac Licence","values":["true"]},{"key":"others:access_status","label":"Others Access Status","values":["open.access"]}]}],"canonical_facts":{"dc:creator":["Hilbrecht, Robin Frances"],"dc:date.accessioned":["2025-04-08T20:31:54Z"],"dc:date.available":["2025-04-08T20:31:54Z"],"dc:date.issued":["2024"],"dc:description.abstract":["Hygrothermal performance is an essential component of building performance, with heat, air, and moisture transport through the building envelope as a key element. Current modelling programs such as Delphin can be used to simulate hygrothermal performance of building envelopes but require physical data for validation, either from in-situ or controlled laboratory experiments. This allows for confidence in the use of hygrothermal models. This thesis used a two-storey guarded hot box (GHB) apparatus to develop a testing sequence that provided sufficient data for confidence in validation. Two lightweight vertical walls were tested in the GHB, each for 1200 hours. The model validation was completed using graphical and statistical analysis. After an initial validation, model adjustments were completed based on the sensitivity of various model parameters. The improved models resulted in excellent agreement between the experimental and modelled performance."],"dc:identifier.doi":["10.22215/etd/2024-16150"],"dc:identifier.uri":["https://hdl.handle.net/20.500.14718/42119"],"dc:language.iso":["en"],"dc:publisher":["Carleton University"],"dc:rights":["Copyright © 2024 the author(s). Theses may be used for non-commercial research, educational, or related academic purposes only. Such uses include personal study, distribution to students, research and scholarship. Theses may only be shared by linking to the Carleton University Institutional Repository and no part may be copied without proper attribution to the author; no part may be used for commercial purposes directly or indirectly via a for-profit platform; no adaptation or derivative works are permitted without consent from the copyright owner."],"dc:subject.lcsh":["Civil engineering","Mechanical engineering","Engineering"],"dc:title":["Development of a Hygrothermal Model Validation Methodology Using a Two-Storey Guarded Hot Box"],"dc:type":["thesis"],"local:lac.licence":["true"],"others:access_status":["open.access"],"thesis:degree_discipline":["Engineering, Sustainable Energy"],"thesis:degree_level":["Master's"],"thesis:degree_name":["Master of Applied Science (M.App.Sc.)"]},"updated_at":"2026-11-19T07:05:39Z"}