{"id":{"repo_id":"carleton","oai_identifier":"oai:carleton.scholaris.ca:20.500.14718/42293"},"canonical_url":"https://search.ndltd.org/etd/carleton/oai:carleton.scholaris.ca:20.500.14718/42293","repository":{"repo_id":"carleton","name":"Carleton University","base_url":"https://carleton.scholaris.ca/server/oai/request"},"display":{"title":"Application of Tissue Equivalent Proportional Counter (TEPC) in Intercalibration with NaI (Tl) Spectrometer","abstract":"Tissue equivalent proportional counters (TEPCs) are recognized as standard instrument for cosmic radiation dose measurement because it can separate gamma and neutron spectra in mixed field microdosimetry. HAWK TEPC was employed in the project as a reference instrument to measure the cosmic radiation exposure in terms of dose equivalent and ambient dose equivalent at ground level, calibrate and compare the doses obtained from the analytical model based on Excel-based Program for Calculating Atmospheric Cosmic Ray Spectrum (EXPACS) and the overflow channel of Canada's Fixed Point Surveillance (FPS) spectrometer. The process of understanding the performance of TEPC as well as designed experiments for cosmic radiation dose measurement done at 8 different locations were presented. Experimental doses obtained with TEPC is consistent with the analytical results, the minimum and maximum discrepancies are 3.8 % and 26.8 % respectively. The work will be further evaluated and applied to other FPS stations.","abstract_html":"Tissue equivalent proportional counters (TEPCs) are recognized as standard instrument for cosmic radiation dose measurement because it can separate gamma and neutron spectra in mixed field microdosimetry. HAWK TEPC was employed in the project as a reference instrument to measure the cosmic radiation exposure in terms of dose equivalent and ambient dose equivalent at ground level, calibrate and compare the doses obtained from the analytical model based on Excel-based Program for Calculating Atmospheric Cosmic Ray Spectrum (EXPACS) and the overflow channel of Canada&#x27;s Fixed Point Surveillance (FPS) spectrometer. The process of understanding the performance of TEPC as well as designed experiments for cosmic radiation dose measurement done at 8 different locations were presented. Experimental doses obtained with TEPC is consistent with the analytical results, the minimum and maximum discrepancies are 3.8 % and 26.8 % respectively. The work will be further evaluated and applied to other FPS stations.","abstract_has_math":false,"creators":["Ma, Haiqian"],"institution":"Carleton University","degree_name":"Master of Science (M.Sc.)","degree_level":"Master's","degree_discipline":"Physics","degree_department":null,"school":null,"contributors":[],"advisors":[],"committee_chairs":[],"committee_members":[],"year":2022,"date_issued":"2022","date_published":"2022","updated_at":"2026-11-19T06:53:10Z","subjects":["Physics","Radiation"],"languages":["en"],"rights":["Copyright © 2022 the author(s). Theses may be used for non-commercial research, educational, or related academic purposes only. Such uses include personal study, research, scholarship, and teaching. Theses may only be shared by linking to Carleton University Institutional Repository and no part may be used without proper attribution to the author. No part may be used for commercial purposes directly or indirectly via a for-profit platform; no adaptation or derivative works are permitted without consent from the copyright owner."],"rights_urls":[],"identifier_entries":[{"key":"dc:identifier.doi","label":"DOI","values":["10.22215/etd/2022-14881"],"render_values":[{"text":"10.22215/etd/2022-14881","href":"https://doi.org/10.22215/etd/2022-14881","code":true}]}],"person_identifier_entries":[]},"links":{"outbound_url":"https://hdl.handle.net/20.500.14718/42293","outbound_label":"Handle","outbound_source":"dc:identifier.uri","record_url":"https://hdl.handle.net/20.500.14718/42293","record_label":"Repository record","record_kind":"handle","record_source":"dc:identifier.uri","download_url":null,"download_label":null,"download_source":null,"access_status":null,"embargo_until":null,"access_note":null},"source_record":{"url":"https://carleton.scholaris.ca/server/oai/request?verb=GetRecord&metadataPrefix=dim&identifier=oai%3Acarleton.scholaris.ca%3A20.500.14718%2F42293","prefix":"dim"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:creator","label":"Author","values":["Ma, Haiqian"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2025-04-08T20:34:56Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2025-04-08T20:34:56Z"]},{"key":"dc:date.issued","label":"Date","values":["2022"]},{"key":"dc:publisher","label":"Institution","values":["Carleton University"]},{"key":"dc:type","label":"Dc Type","values":["thesis"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Physics"]},{"key":"thesis:degree_level","label":"Degree Level","values":["Master's"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Master of Science (M.Sc.)"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject.lcsh","label":"Dc Subject Lcsh","values":["Physics","Radiation"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language.iso","label":"Language (ISO)","values":["en"]},{"key":"dc:rights","label":"Dc Rights","values":["Copyright © 2022 the author(s). Theses may be used for non-commercial research, educational, or related academic purposes only. Such uses include personal study, research, scholarship, and teaching. Theses may only be shared by linking to Carleton University Institutional Repository and no part may be used without proper attribution to the author. No part may be used for commercial purposes directly or indirectly via a for-profit platform; no adaptation or derivative works are permitted without consent from the copyright owner."]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.doi","label":"DOI","values":["10.22215/etd/2022-14881"]},{"key":"dc:identifier.uri","label":"Identifier URI","values":["https://hdl.handle.net/20.500.14718/42293"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["Tissue equivalent proportional counters (TEPCs) are recognized as standard instrument for cosmic radiation dose measurement because it can separate gamma and neutron spectra in mixed field microdosimetry. HAWK TEPC was employed in the project as a reference instrument to measure the cosmic radiation exposure in terms of dose equivalent and ambient dose equivalent at ground level, calibrate and compare the doses obtained from the analytical model based on Excel-based Program for Calculating Atmospheric Cosmic Ray Spectrum (EXPACS) and the overflow channel of Canada's Fixed Point Surveillance (FPS) spectrometer. The process of understanding the performance of TEPC as well as designed experiments for cosmic radiation dose measurement done at 8 different locations were presented. Experimental doses obtained with TEPC is consistent with the analytical results, the minimum and maximum discrepancies are 3.8 % and 26.8 % respectively. The work will be further evaluated and applied to other FPS stations."]},{"key":"dc:title","label":"Title","values":["Application of Tissue Equivalent Proportional Counter (TEPC) in Intercalibration with NaI (Tl) Spectrometer"]},{"key":"local:lac.licence","label":"Local Lac Licence","values":["true"]},{"key":"others:access_status","label":"Others Access Status","values":["open.access"]}]}],"canonical_facts":{"dc:creator":["Ma, Haiqian"],"dc:date.accessioned":["2025-04-08T20:34:56Z"],"dc:date.available":["2025-04-08T20:34:56Z"],"dc:date.issued":["2022"],"dc:description.abstract":["Tissue equivalent proportional counters (TEPCs) are recognized as standard instrument for cosmic radiation dose measurement because it can separate gamma and neutron spectra in mixed field microdosimetry. HAWK TEPC was employed in the project as a reference instrument to measure the cosmic radiation exposure in terms of dose equivalent and ambient dose equivalent at ground level, calibrate and compare the doses obtained from the analytical model based on Excel-based Program for Calculating Atmospheric Cosmic Ray Spectrum (EXPACS) and the overflow channel of Canada's Fixed Point Surveillance (FPS) spectrometer. The process of understanding the performance of TEPC as well as designed experiments for cosmic radiation dose measurement done at 8 different locations were presented. Experimental doses obtained with TEPC is consistent with the analytical results, the minimum and maximum discrepancies are 3.8 % and 26.8 % respectively. The work will be further evaluated and applied to other FPS stations."],"dc:identifier.doi":["10.22215/etd/2022-14881"],"dc:identifier.uri":["https://hdl.handle.net/20.500.14718/42293"],"dc:language.iso":["en"],"dc:publisher":["Carleton University"],"dc:rights":["Copyright © 2022 the author(s). Theses may be used for non-commercial research, educational, or related academic purposes only. Such uses include personal study, research, scholarship, and teaching. Theses may only be shared by linking to Carleton University Institutional Repository and no part may be used without proper attribution to the author. No part may be used for commercial purposes directly or indirectly via a for-profit platform; no adaptation or derivative works are permitted without consent from the copyright owner."],"dc:subject.lcsh":["Physics","Radiation"],"dc:title":["Application of Tissue Equivalent Proportional Counter (TEPC) in Intercalibration with NaI (Tl) Spectrometer"],"dc:type":["thesis"],"local:lac.licence":["true"],"others:access_status":["open.access"],"thesis:degree_discipline":["Physics"],"thesis:degree_level":["Master's"],"thesis:degree_name":["Master of Science (M.Sc.)"]},"updated_at":"2026-11-19T06:53:10Z"}