{"id":{"repo_id":"carleton","oai_identifier":"oai:carleton.scholaris.ca:20.500.14718/42469"},"canonical_url":"https://search.ndltd.org/etd/carleton/oai:carleton.scholaris.ca:20.500.14718/42469","repository":{"repo_id":"carleton","name":"Carleton University","base_url":"https://carleton.scholaris.ca/server/oai/request"},"display":{"title":"Kernel-Based PET Image Reconstruction using Dynamic PET and MR Anatomical Information","abstract":"Positron emission tomography (PET) imaging is used to track biochemical processes in the human body. PET image quality is limited by noise and several methods have been implemented to improve the quality. Kernel-based image reconstruction is among the methods implemented to increase PET image quality and commonly uses a Gaussian kernel. Unfortunately, the Gaussian kernel tends to smooth details in the reconstructed image. To reduce noise without losing contrast details, a different kernel is needed. This work gives an overview of Gaussian kernel PET image reconstruction and focuses on finding substitutes for the Gaussian kernel that tackles its shortcomings. A wavelet kernel can be more efficient than the Gaussian kernel in reducing noise while keeping contrast details by better separating signal from noise and thus it does not over smooth peak values in the final reconstructed images. In this thesis, a wavelet kernel was first applied on prior information derived from dynamic PET series, and its usefulness has been evaluated using simulated brain data, physical phantom data and patient data. Reconstruction results are presented and discussed in detail comparing the wavelet kernel method with the Gaussian kernel method. In the next step, using magnetic resonance (MR) information as prior information for kernel-based PET image reconstruction, the wavelet method is improved and extended by proposing a multi-scale wavelet kernel. This method identifies the directionality in the MR image and includes that information for kernel construction as well. Methods developed in this thesis allow for higher SNR in the reconstructed PET image while preserving contrast. They also produce reconstructed PET images with higher visual quality compared to Gaussian kernel methods.","abstract_html":"Positron emission tomography (PET) imaging is used to track biochemical processes in the human body. PET image quality is limited by noise and several methods have been implemented to improve the quality. Kernel-based image reconstruction is among the methods implemented to increase PET image quality and commonly uses a Gaussian kernel. Unfortunately, the Gaussian kernel tends to smooth details in the reconstructed image. To reduce noise without losing contrast details, a different kernel is needed. This work gives an overview of Gaussian kernel PET image reconstruction and focuses on finding substitutes for the Gaussian kernel that tackles its shortcomings. A wavelet kernel can be more efficient than the Gaussian kernel in reducing noise while keeping contrast details by better separating signal from noise and thus it does not over smooth peak values in the final reconstructed images. In this thesis, a wavelet kernel was first applied on prior information derived from dynamic PET series, and its usefulness has been evaluated using simulated brain data, physical phantom data and patient data. Reconstruction results are presented and discussed in detail comparing the wavelet kernel method with the Gaussian kernel method. In the next step, using magnetic resonance (MR) information as prior information for kernel-based PET image reconstruction, the wavelet method is improved and extended by proposing a multi-scale wavelet kernel. This method identifies the directionality in the MR image and includes that information for kernel construction as well. Methods developed in this thesis allow for higher SNR in the reconstructed PET image while preserving contrast. They also produce reconstructed PET images with higher visual quality compared to Gaussian kernel methods.","abstract_has_math":false,"creators":["Ashouri Talouki, Zahra"],"institution":"Carleton University","degree_name":"Doctor of Philosophy (Ph.D.)","degree_level":"Doctoral","degree_discipline":"Engineering, Electrical and Computer","degree_department":null,"school":null,"contributors":[],"advisors":[],"committee_chairs":[],"committee_members":[],"year":2022,"date_issued":"2022","date_published":"2022","updated_at":"2026-11-19T07:13:56Z","subjects":["Electrical engineering","Biomedical engineering"],"languages":["en"],"rights":["Copyright © 2022 the author(s). Theses may be used for non-commercial research, educational, or related academic purposes only. Such uses include personal study, research, scholarship, and teaching. Theses may only be shared by linking to Carleton University Institutional Repository and no part may be used without proper attribution to the author. No part may be used for commercial purposes directly or indirectly via a for-profit platform; no adaptation or derivative works are permitted without consent from the copyright owner."],"rights_urls":[],"identifier_entries":[{"key":"dc:identifier.doi","label":"DOI","values":["10.22215/etd/2022-14975"],"render_values":[{"text":"10.22215/etd/2022-14975","href":"https://doi.org/10.22215/etd/2022-14975","code":true}]}],"person_identifier_entries":[]},"links":{"outbound_url":"https://hdl.handle.net/20.500.14718/42469","outbound_label":"Handle","outbound_source":"dc:identifier.uri","record_url":"https://hdl.handle.net/20.500.14718/42469","record_label":"Repository record","record_kind":"handle","record_source":"dc:identifier.uri","download_url":null,"download_label":null,"download_source":null,"access_status":null,"embargo_until":null,"access_note":null},"source_record":{"url":"https://carleton.scholaris.ca/server/oai/request?verb=GetRecord&metadataPrefix=dim&identifier=oai%3Acarleton.scholaris.ca%3A20.500.14718%2F42469","prefix":"dim"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:creator","label":"Author","values":["Ashouri Talouki, Zahra"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2025-04-08T20:38:12Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2025-04-08T20:38:12Z"]},{"key":"dc:date.issued","label":"Date","values":["2022"]},{"key":"dc:publisher","label":"Institution","values":["Carleton University"]},{"key":"dc:type","label":"Dc Type","values":["thesis"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Engineering, Electrical and Computer"]},{"key":"thesis:degree_level","label":"Degree Level","values":["Doctoral"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Doctor of Philosophy (Ph.D.)"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject.lcsh","label":"Dc Subject Lcsh","values":["Electrical engineering","Biomedical engineering"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language.iso","label":"Language (ISO)","values":["en"]},{"key":"dc:rights","label":"Dc Rights","values":["Copyright © 2022 the author(s). Theses may be used for non-commercial research, educational, or related academic purposes only. Such uses include personal study, research, scholarship, and teaching. Theses may only be shared by linking to Carleton University Institutional Repository and no part may be used without proper attribution to the author. No part may be used for commercial purposes directly or indirectly via a for-profit platform; no adaptation or derivative works are permitted without consent from the copyright owner."]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.doi","label":"DOI","values":["10.22215/etd/2022-14975"]},{"key":"dc:identifier.uri","label":"Identifier URI","values":["https://hdl.handle.net/20.500.14718/42469"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["Positron emission tomography (PET) imaging is used to track biochemical processes in the human body. PET image quality is limited by noise and several methods have been implemented to improve the quality. Kernel-based image reconstruction is among the methods implemented to increase PET image quality and commonly uses a Gaussian kernel. Unfortunately, the Gaussian kernel tends to smooth details in the reconstructed image. To reduce noise without losing contrast details, a different kernel is needed. This work gives an overview of Gaussian kernel PET image reconstruction and focuses on finding substitutes for the Gaussian kernel that tackles its shortcomings. A wavelet kernel can be more efficient than the Gaussian kernel in reducing noise while keeping contrast details by better separating signal from noise and thus it does not over smooth peak values in the final reconstructed images. In this thesis, a wavelet kernel was first applied on prior information derived from dynamic PET series, and its usefulness has been evaluated using simulated brain data, physical phantom data and patient data. Reconstruction results are presented and discussed in detail comparing the wavelet kernel method with the Gaussian kernel method. In the next step, using magnetic resonance (MR) information as prior information for kernel-based PET image reconstruction, the wavelet method is improved and extended by proposing a multi-scale wavelet kernel. This method identifies the directionality in the MR image and includes that information for kernel construction as well. Methods developed in this thesis allow for higher SNR in the reconstructed PET image while preserving contrast. They also produce reconstructed PET images with higher visual quality compared to Gaussian kernel methods."]},{"key":"dc:title","label":"Title","values":["Kernel-Based PET Image Reconstruction using Dynamic PET and MR Anatomical Information"]},{"key":"local:lac.licence","label":"Local Lac Licence","values":["true"]},{"key":"others:access_status","label":"Others Access Status","values":["open.access"]}]}],"canonical_facts":{"dc:creator":["Ashouri Talouki, Zahra"],"dc:date.accessioned":["2025-04-08T20:38:12Z"],"dc:date.available":["2025-04-08T20:38:12Z"],"dc:date.issued":["2022"],"dc:description.abstract":["Positron emission tomography (PET) imaging is used to track biochemical processes in the human body. PET image quality is limited by noise and several methods have been implemented to improve the quality. Kernel-based image reconstruction is among the methods implemented to increase PET image quality and commonly uses a Gaussian kernel. Unfortunately, the Gaussian kernel tends to smooth details in the reconstructed image. To reduce noise without losing contrast details, a different kernel is needed. This work gives an overview of Gaussian kernel PET image reconstruction and focuses on finding substitutes for the Gaussian kernel that tackles its shortcomings. A wavelet kernel can be more efficient than the Gaussian kernel in reducing noise while keeping contrast details by better separating signal from noise and thus it does not over smooth peak values in the final reconstructed images. In this thesis, a wavelet kernel was first applied on prior information derived from dynamic PET series, and its usefulness has been evaluated using simulated brain data, physical phantom data and patient data. Reconstruction results are presented and discussed in detail comparing the wavelet kernel method with the Gaussian kernel method. In the next step, using magnetic resonance (MR) information as prior information for kernel-based PET image reconstruction, the wavelet method is improved and extended by proposing a multi-scale wavelet kernel. This method identifies the directionality in the MR image and includes that information for kernel construction as well. Methods developed in this thesis allow for higher SNR in the reconstructed PET image while preserving contrast. They also produce reconstructed PET images with higher visual quality compared to Gaussian kernel methods."],"dc:identifier.doi":["10.22215/etd/2022-14975"],"dc:identifier.uri":["https://hdl.handle.net/20.500.14718/42469"],"dc:language.iso":["en"],"dc:publisher":["Carleton University"],"dc:rights":["Copyright © 2022 the author(s). Theses may be used for non-commercial research, educational, or related academic purposes only. Such uses include personal study, research, scholarship, and teaching. Theses may only be shared by linking to Carleton University Institutional Repository and no part may be used without proper attribution to the author. No part may be used for commercial purposes directly or indirectly via a for-profit platform; no adaptation or derivative works are permitted without consent from the copyright owner."],"dc:subject.lcsh":["Electrical engineering","Biomedical engineering"],"dc:title":["Kernel-Based PET Image Reconstruction using Dynamic PET and MR Anatomical Information"],"dc:type":["thesis"],"local:lac.licence":["true"],"others:access_status":["open.access"],"thesis:degree_discipline":["Engineering, Electrical and Computer"],"thesis:degree_level":["Doctoral"],"thesis:degree_name":["Doctor of Philosophy (Ph.D.)"]},"updated_at":"2026-11-19T07:13:56Z"}