{"id":{"repo_id":"carleton","oai_identifier":"oai:carleton.scholaris.ca:20.500.14718/42527"},"canonical_url":"https://search.ndltd.org/etd/carleton/oai:carleton.scholaris.ca:20.500.14718/42527","repository":{"repo_id":"carleton","name":"Carleton University","base_url":"https://carleton.scholaris.ca/server/oai/request"},"display":{"title":"Improving the Fire-Resistance Rating of Concrete Masonry Walls Through the Use of Insulations : An Experimental and Numerical Study","abstract":"For non-loadbearing applications, the 15 cm blocks are usually used. They are lightweight, easy to install, and are cost-effective. The fire-resistance rating of the 15 cm block is about 1 h, while that of a 20 cm block is about 2 h. This reduced fire-resistance rating is due to smaller cells which leads to more convective and radiative heat transfer inside of the block cells, as well as the reduced face cells that cause the blocks to heat up quicker. With the use of lightweight insulation materials as cell fillers, an improvement in the fire-resistance rating was achieved for the 15 cm block. These materials were able to reduce the convective and radiative heat transfer in the cells. For the experimental and numerical analysis carried out, vermiculite, and gypsum were able to improve the fire ratings by at least 1h.","abstract_html":"For non-loadbearing applications, the 15 cm blocks are usually used. They are lightweight, easy to install, and are cost-effective. The fire-resistance rating of the 15 cm block is about 1 h, while that of a 20 cm block is about 2 h. This reduced fire-resistance rating is due to smaller cells which leads to more convective and radiative heat transfer inside of the block cells, as well as the reduced face cells that cause the blocks to heat up quicker. With the use of lightweight insulation materials as cell fillers, an improvement in the fire-resistance rating was achieved for the 15 cm block. These materials were able to reduce the convective and radiative heat transfer in the cells. For the experimental and numerical analysis carried out, vermiculite, and gypsum were able to improve the fire ratings by at least 1h.","abstract_has_math":false,"creators":["Bobmanuel, Oprite Nimisoere-Huchinson"],"institution":"Carleton University","degree_name":"Master of Applied Science (M.App.Sc.)","degree_level":"Master's","degree_discipline":"Engineering, Civil","degree_department":null,"school":null,"contributors":[],"advisors":[],"committee_chairs":[],"committee_members":[],"year":2021,"date_issued":"2021","date_published":"2021","updated_at":"2026-11-19T06:59:10Z","subjects":["Civil engineering","Environmental engineering","Engineering"],"languages":["en"],"rights":["Copyright © 2021 the author(s). Theses may be used for non-commercial research, educational, or related academic purposes only. Such uses include personal study, research, scholarship, and teaching. Theses may only be shared by linking to Carleton University Institutional Repository and no part may be used without proper attribution to the author. No part may be used for commercial purposes directly or indirectly via a for-profit platform; no adaptation or derivative works are permitted without consent from the copyright owner."],"rights_urls":[],"identifier_entries":[{"key":"dc:identifier.doi","label":"DOI","values":["10.22215/etd/2021-14805"],"render_values":[{"text":"10.22215/etd/2021-14805","href":"https://doi.org/10.22215/etd/2021-14805","code":true}]}],"person_identifier_entries":[]},"links":{"outbound_url":"https://hdl.handle.net/20.500.14718/42527","outbound_label":"Handle","outbound_source":"dc:identifier.uri","record_url":"https://hdl.handle.net/20.500.14718/42527","record_label":"Repository record","record_kind":"handle","record_source":"dc:identifier.uri","download_url":null,"download_label":null,"download_source":null,"access_status":null,"embargo_until":null,"access_note":null},"source_record":{"url":"https://carleton.scholaris.ca/server/oai/request?verb=GetRecord&metadataPrefix=dim&identifier=oai%3Acarleton.scholaris.ca%3A20.500.14718%2F42527","prefix":"dim"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:creator","label":"Author","values":["Bobmanuel, Oprite Nimisoere-Huchinson"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2025-04-08T20:39:18Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2025-04-08T20:39:18Z"]},{"key":"dc:date.issued","label":"Date","values":["2021"]},{"key":"dc:publisher","label":"Institution","values":["Carleton University"]},{"key":"dc:type","label":"Dc Type","values":["thesis"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Engineering, Civil"]},{"key":"thesis:degree_level","label":"Degree Level","values":["Master's"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Master of Applied Science (M.App.Sc.)"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject.lcsh","label":"Dc Subject Lcsh","values":["Civil engineering","Environmental engineering","Engineering"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language.iso","label":"Language (ISO)","values":["en"]},{"key":"dc:rights","label":"Dc Rights","values":["Copyright © 2021 the author(s). Theses may be used for non-commercial research, educational, or related academic purposes only. Such uses include personal study, research, scholarship, and teaching. Theses may only be shared by linking to Carleton University Institutional Repository and no part may be used without proper attribution to the author. No part may be used for commercial purposes directly or indirectly via a for-profit platform; no adaptation or derivative works are permitted without consent from the copyright owner."]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.doi","label":"DOI","values":["10.22215/etd/2021-14805"]},{"key":"dc:identifier.uri","label":"Identifier URI","values":["https://hdl.handle.net/20.500.14718/42527"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["For non-loadbearing applications, the 15 cm blocks are usually used. They are lightweight, easy to install, and are cost-effective. The fire-resistance rating of the 15 cm block is about 1 h, while that of a 20 cm block is about 2 h. This reduced fire-resistance rating is due to smaller cells which leads to more convective and radiative heat transfer inside of the block cells, as well as the reduced face cells that cause the blocks to heat up quicker. With the use of lightweight insulation materials as cell fillers, an improvement in the fire-resistance rating was achieved for the 15 cm block. These materials were able to reduce the convective and radiative heat transfer in the cells. For the experimental and numerical analysis carried out, vermiculite, and gypsum were able to improve the fire ratings by at least 1h."]},{"key":"dc:title","label":"Title","values":["Improving the Fire-Resistance Rating of Concrete Masonry Walls Through the Use of Insulations : An Experimental and Numerical Study"]},{"key":"local:lac.licence","label":"Local Lac Licence","values":["true"]},{"key":"others:access_status","label":"Others Access Status","values":["open.access"]}]}],"canonical_facts":{"dc:creator":["Bobmanuel, Oprite Nimisoere-Huchinson"],"dc:date.accessioned":["2025-04-08T20:39:18Z"],"dc:date.available":["2025-04-08T20:39:18Z"],"dc:date.issued":["2021"],"dc:description.abstract":["For non-loadbearing applications, the 15 cm blocks are usually used. They are lightweight, easy to install, and are cost-effective. The fire-resistance rating of the 15 cm block is about 1 h, while that of a 20 cm block is about 2 h. This reduced fire-resistance rating is due to smaller cells which leads to more convective and radiative heat transfer inside of the block cells, as well as the reduced face cells that cause the blocks to heat up quicker. With the use of lightweight insulation materials as cell fillers, an improvement in the fire-resistance rating was achieved for the 15 cm block. These materials were able to reduce the convective and radiative heat transfer in the cells. For the experimental and numerical analysis carried out, vermiculite, and gypsum were able to improve the fire ratings by at least 1h."],"dc:identifier.doi":["10.22215/etd/2021-14805"],"dc:identifier.uri":["https://hdl.handle.net/20.500.14718/42527"],"dc:language.iso":["en"],"dc:publisher":["Carleton University"],"dc:rights":["Copyright © 2021 the author(s). Theses may be used for non-commercial research, educational, or related academic purposes only. Such uses include personal study, research, scholarship, and teaching. Theses may only be shared by linking to Carleton University Institutional Repository and no part may be used without proper attribution to the author. No part may be used for commercial purposes directly or indirectly via a for-profit platform; no adaptation or derivative works are permitted without consent from the copyright owner."],"dc:subject.lcsh":["Civil engineering","Environmental engineering","Engineering"],"dc:title":["Improving the Fire-Resistance Rating of Concrete Masonry Walls Through the Use of Insulations : An Experimental and Numerical Study"],"dc:type":["thesis"],"local:lac.licence":["true"],"others:access_status":["open.access"],"thesis:degree_discipline":["Engineering, Civil"],"thesis:degree_level":["Master's"],"thesis:degree_name":["Master of Applied Science (M.App.Sc.)"]},"updated_at":"2026-11-19T06:59:10Z"}