{"id":{"repo_id":"carleton","oai_identifier":"oai:carleton.scholaris.ca:20.500.14718/42669"},"canonical_url":"https://search.ndltd.org/etd/carleton/oai:carleton.scholaris.ca:20.500.14718/42669","repository":{"repo_id":"carleton","name":"Carleton University","base_url":"https://carleton.scholaris.ca/server/oai/request"},"display":{"title":"The use of EEG and VR in Mental State Recognition","abstract":"Mental state recognition (MSR) is important to multiple health-related fields. A virtual reality (VR) headset is used to induce mental states through both distractors and stressors. Participants solved arithmetic questions in VR, then outside of VR using a Muse S EEG device. A heart monitor was used throughout. Three research contributions followed: First, heart rate variability (HRV) data were compared between VR and non-VR sessions and correlated with established Test of Variables of Attention (T.O.V.A.) measurements used to asses participants' attention and focus. Second, a classifier was developed to differentiate between clean and noisy EEG data, with 92% accuracy. Lastly, linear regression models were developed, achieving mean squared error scores of 0.65 and 0.63 for 3-level stress and attention prediction from EEG data, respectively. In summary, this thesis explores the use of VR to induce mental states and advances the state of the art in EEG-based MSR.","abstract_html":"Mental state recognition (MSR) is important to multiple health-related fields. A virtual reality (VR) headset is used to induce mental states through both distractors and stressors. Participants solved arithmetic questions in VR, then outside of VR using a Muse S EEG device. A heart monitor was used throughout. Three research contributions followed: First, heart rate variability (HRV) data were compared between VR and non-VR sessions and correlated with established Test of Variables of Attention (T.O.V.A.) measurements used to asses participants&#x27; attention and focus. Second, a classifier was developed to differentiate between clean and noisy EEG data, with 92% accuracy. Lastly, linear regression models were developed, achieving mean squared error scores of 0.65 and 0.63 for 3-level stress and attention prediction from EEG data, respectively. In summary, this thesis explores the use of VR to induce mental states and advances the state of the art in EEG-based MSR.","abstract_has_math":false,"creators":["El-Habrouk, Jaser"],"institution":"Carleton University","degree_name":"Master of Applied Science (M.App.Sc.)","degree_level":"Master's","degree_discipline":"Engineering, Biomedical","degree_department":null,"school":null,"contributors":[],"advisors":[],"committee_chairs":[],"committee_members":[],"year":2023,"date_issued":"2023","date_published":"2023","updated_at":"2026-11-19T07:09:50Z","subjects":["Biomedical engineering"],"languages":["en"],"rights":["Copyright © 2023 the author(s). Theses may be used for non-commercial research, educational, or related academic purposes only. Such uses include personal study, research, scholarship, and teaching. Theses may only be shared by linking to Carleton University Institutional Repository and no part may be used without proper attribution to the author. No part may be used for commercial purposes directly or indirectly via a for-profit platform; no adaptation or derivative works are permitted without consent from the copyright owner."],"rights_urls":[],"identifier_entries":[{"key":"dc:identifier.doi","label":"DOI","values":["10.22215/etd/2023-15455"],"render_values":[{"text":"10.22215/etd/2023-15455","href":"https://doi.org/10.22215/etd/2023-15455","code":true}]}],"person_identifier_entries":[]},"links":{"outbound_url":"https://hdl.handle.net/20.500.14718/42669","outbound_label":"Handle","outbound_source":"dc:identifier.uri","record_url":"https://hdl.handle.net/20.500.14718/42669","record_label":"Repository record","record_kind":"handle","record_source":"dc:identifier.uri","download_url":null,"download_label":null,"download_source":null,"access_status":null,"embargo_until":null,"access_note":null},"source_record":{"url":"https://carleton.scholaris.ca/server/oai/request?verb=GetRecord&metadataPrefix=dim&identifier=oai%3Acarleton.scholaris.ca%3A20.500.14718%2F42669","prefix":"dim"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:creator","label":"Author","values":["El-Habrouk, Jaser"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2025-04-08T20:41:52Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2025-04-08T20:41:52Z"]},{"key":"dc:date.issued","label":"Date","values":["2023"]},{"key":"dc:publisher","label":"Institution","values":["Carleton University"]},{"key":"dc:type","label":"Dc Type","values":["thesis"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Engineering, Biomedical"]},{"key":"thesis:degree_level","label":"Degree Level","values":["Master's"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Master of Applied Science (M.App.Sc.)"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject.lcsh","label":"Dc Subject Lcsh","values":["Biomedical engineering"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language.iso","label":"Language (ISO)","values":["en"]},{"key":"dc:rights","label":"Dc Rights","values":["Copyright © 2023 the author(s). Theses may be used for non-commercial research, educational, or related academic purposes only. Such uses include personal study, research, scholarship, and teaching. Theses may only be shared by linking to Carleton University Institutional Repository and no part may be used without proper attribution to the author. No part may be used for commercial purposes directly or indirectly via a for-profit platform; no adaptation or derivative works are permitted without consent from the copyright owner."]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.doi","label":"DOI","values":["10.22215/etd/2023-15455"]},{"key":"dc:identifier.uri","label":"Identifier URI","values":["https://hdl.handle.net/20.500.14718/42669"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["Mental state recognition (MSR) is important to multiple health-related fields. A virtual reality (VR) headset is used to induce mental states through both distractors and stressors. Participants solved arithmetic questions in VR, then outside of VR using a Muse S EEG device. A heart monitor was used throughout. Three research contributions followed: First, heart rate variability (HRV) data were compared between VR and non-VR sessions and correlated with established Test of Variables of Attention (T.O.V.A.) measurements used to asses participants' attention and focus. Second, a classifier was developed to differentiate between clean and noisy EEG data, with 92% accuracy. Lastly, linear regression models were developed, achieving mean squared error scores of 0.65 and 0.63 for 3-level stress and attention prediction from EEG data, respectively. In summary, this thesis explores the use of VR to induce mental states and advances the state of the art in EEG-based MSR."]},{"key":"dc:title","label":"Title","values":["The use of EEG and VR in Mental State Recognition"]},{"key":"local:lac.licence","label":"Local Lac Licence","values":["true"]},{"key":"others:access_status","label":"Others Access Status","values":["open.access"]}]}],"canonical_facts":{"dc:creator":["El-Habrouk, Jaser"],"dc:date.accessioned":["2025-04-08T20:41:52Z"],"dc:date.available":["2025-04-08T20:41:52Z"],"dc:date.issued":["2023"],"dc:description.abstract":["Mental state recognition (MSR) is important to multiple health-related fields. A virtual reality (VR) headset is used to induce mental states through both distractors and stressors. Participants solved arithmetic questions in VR, then outside of VR using a Muse S EEG device. A heart monitor was used throughout. Three research contributions followed: First, heart rate variability (HRV) data were compared between VR and non-VR sessions and correlated with established Test of Variables of Attention (T.O.V.A.) measurements used to asses participants' attention and focus. Second, a classifier was developed to differentiate between clean and noisy EEG data, with 92% accuracy. Lastly, linear regression models were developed, achieving mean squared error scores of 0.65 and 0.63 for 3-level stress and attention prediction from EEG data, respectively. In summary, this thesis explores the use of VR to induce mental states and advances the state of the art in EEG-based MSR."],"dc:identifier.doi":["10.22215/etd/2023-15455"],"dc:identifier.uri":["https://hdl.handle.net/20.500.14718/42669"],"dc:language.iso":["en"],"dc:publisher":["Carleton University"],"dc:rights":["Copyright © 2023 the author(s). Theses may be used for non-commercial research, educational, or related academic purposes only. Such uses include personal study, research, scholarship, and teaching. Theses may only be shared by linking to Carleton University Institutional Repository and no part may be used without proper attribution to the author. No part may be used for commercial purposes directly or indirectly via a for-profit platform; no adaptation or derivative works are permitted without consent from the copyright owner."],"dc:subject.lcsh":["Biomedical engineering"],"dc:title":["The use of EEG and VR in Mental State Recognition"],"dc:type":["thesis"],"local:lac.licence":["true"],"others:access_status":["open.access"],"thesis:degree_discipline":["Engineering, Biomedical"],"thesis:degree_level":["Master's"],"thesis:degree_name":["Master of Applied Science (M.App.Sc.)"]},"updated_at":"2026-11-19T07:09:50Z"}