{"id":{"repo_id":"carleton","oai_identifier":"oai:carleton.scholaris.ca:20.500.14718/42684"},"canonical_url":"https://search.ndltd.org/etd/carleton/oai:carleton.scholaris.ca:20.500.14718/42684","repository":{"repo_id":"carleton","name":"Carleton University","base_url":"https://carleton.scholaris.ca/server/oai/request"},"display":{"title":"Design, Manufacturing, and Characterization of a Novel Ceramic Matrix Composite","abstract":"A novel ceramic matrix composite (CMC) system consisting of a commercially available SiC fibre, variations of electrophoretically deposited (EPD) fibre-matrix interphases, and a liquid metal melt infiltrated matrix was designed and characterised. A factorial design of experiments approach was undertaken to evaluate the deposition variables which would result in a functioning fibre-matrix interphase. A 25-2 partial factorial design matrix was selected with factors: electric potential, deposition time, surfactant, binder, and solids loading. The design matrix was replicated for four different EPD fibre-matrix interphase coating combinations: Al2O3/SiC, BN/PSZ, ZrC/ZTA, and SiC/Si3N4/SiC. Microcomposites were evaluated for tensile properties using a standard displacement controlled tensile test program. Microcomposites were tested at room temperature immediately following fabrication and following exposure to a standard atmosphere at 1000 °C for 1 h. Samples with ZrC/ZTA and SiC/Si3N4/SiC coatings demonstrated the best tensile properties in room temperature tests while samples with BN/PSZ and SiC/Si3N4/SiC coatings demonstrated the best retention of tensile properties following high temperature exposure. Subsequent SEM analysis revealed that coatings with smaller particle diameters as the inner layer of the fibre-matrix interphase coating produced more uniform coatings and the less fibre degradation due to oxidation following high temperature exposure. Additional microcomposites were fabricated for high temperature tensile testing; however, these samples were unable to bear recordable loads, an SEM examination revealed significant degradation of the matrix phase beneath the high temperature adhesive. Optical microscopy was used to evaluate coating thicknesses of coated fibre bundles prior to heat treatments. Measured coating thickness indicated that generally higher deposition times resulted in thicker coatings; however, coatings produced using 25 V electric potential were thicker than coatings produced using 12.5 V and 50 V electric potentials. This is likely due to a greater deposition efficiency factor at 25 V. FEA analysis was used to evaluate the electrical properties of an idealized version of the stationary EPD cell. This analysis showed a significant variation in the electric field along the fibre axis as well as a significant variation in electrical field between fibres in the centre of the fibre bundle and on the outer edge of the fibre bundle.","abstract_html":"A novel ceramic matrix composite (CMC) system consisting of a commercially available SiC fibre, variations of electrophoretically deposited (EPD) fibre-matrix interphases, and a liquid metal melt infiltrated matrix was designed and characterised. A factorial design of experiments approach was undertaken to evaluate the deposition variables which would result in a functioning fibre-matrix interphase. A 25-2 partial factorial design matrix was selected with factors: electric potential, deposition time, surfactant, binder, and solids loading. The design matrix was replicated for four different EPD fibre-matrix interphase coating combinations: Al2O3/SiC, BN/PSZ, ZrC/ZTA, and SiC/Si3N4/SiC. Microcomposites were evaluated for tensile properties using a standard displacement controlled tensile test program. Microcomposites were tested at room temperature immediately following fabrication and following exposure to a standard atmosphere at 1000 °C for 1 h. Samples with ZrC/ZTA and SiC/Si3N4/SiC coatings demonstrated the best tensile properties in room temperature tests while samples with BN/PSZ and SiC/Si3N4/SiC coatings demonstrated the best retention of tensile properties following high temperature exposure. Subsequent SEM analysis revealed that coatings with smaller particle diameters as the inner layer of the fibre-matrix interphase coating produced more uniform coatings and the less fibre degradation due to oxidation following high temperature exposure. Additional microcomposites were fabricated for high temperature tensile testing; however, these samples were unable to bear recordable loads, an SEM examination revealed significant degradation of the matrix phase beneath the high temperature adhesive. Optical microscopy was used to evaluate coating thicknesses of coated fibre bundles prior to heat treatments. Measured coating thickness indicated that generally higher deposition times resulted in thicker coatings; however, coatings produced using 25 V electric potential were thicker than coatings produced using 12.5 V and 50 V electric potentials. This is likely due to a greater deposition efficiency factor at 25 V. FEA analysis was used to evaluate the electrical properties of an idealized version of the stationary EPD cell. This analysis showed a significant variation in the electric field along the fibre axis as well as a significant variation in electrical field between fibres in the centre of the fibre bundle and on the outer edge of the fibre bundle.","abstract_has_math":false,"creators":["Robertson, Taylor"],"institution":"Carleton University","degree_name":"Doctor of Philosophy (Ph.D.)","degree_level":"Doctoral","degree_discipline":"Engineering, Mechanical","degree_department":null,"school":null,"contributors":[],"advisors":[],"committee_chairs":[],"committee_members":[],"year":2022,"date_issued":"2022","date_published":"2022","updated_at":"2026-11-19T07:08:56Z","subjects":["Mechanical engineering","Materials science"],"languages":["en"],"rights":["Copyright © 2022 the author(s). Theses may be used for non-commercial research, educational, or related academic purposes only. Such uses include personal study, research, scholarship, and teaching. Theses may only be shared by linking to Carleton University Institutional Repository and no part may be used without proper attribution to the author. No part may be used for commercial purposes directly or indirectly via a for-profit platform; no adaptation or derivative works are permitted without consent from the copyright owner."],"rights_urls":[],"identifier_entries":[{"key":"dc:identifier.doi","label":"DOI","values":["10.22215/etd/2022-15430"],"render_values":[{"text":"10.22215/etd/2022-15430","href":"https://doi.org/10.22215/etd/2022-15430","code":true}]}],"person_identifier_entries":[]},"links":{"outbound_url":"https://hdl.handle.net/20.500.14718/42684","outbound_label":"Handle","outbound_source":"dc:identifier.uri","record_url":"https://hdl.handle.net/20.500.14718/42684","record_label":"Repository record","record_kind":"handle","record_source":"dc:identifier.uri","download_url":null,"download_label":null,"download_source":null,"access_status":null,"embargo_until":null,"access_note":null},"source_record":{"url":"https://carleton.scholaris.ca/server/oai/request?verb=GetRecord&metadataPrefix=dim&identifier=oai%3Acarleton.scholaris.ca%3A20.500.14718%2F42684","prefix":"dim"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:creator","label":"Author","values":["Robertson, Taylor"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2025-04-08T20:42:09Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2025-04-08T20:42:09Z"]},{"key":"dc:date.issued","label":"Date","values":["2022"]},{"key":"dc:publisher","label":"Institution","values":["Carleton University"]},{"key":"dc:type","label":"Dc Type","values":["thesis"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Engineering, Mechanical"]},{"key":"thesis:degree_level","label":"Degree Level","values":["Doctoral"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Doctor of Philosophy (Ph.D.)"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject.lcsh","label":"Dc Subject Lcsh","values":["Mechanical engineering","Materials science"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language.iso","label":"Language (ISO)","values":["en"]},{"key":"dc:rights","label":"Dc Rights","values":["Copyright © 2022 the author(s). Theses may be used for non-commercial research, educational, or related academic purposes only. Such uses include personal study, research, scholarship, and teaching. Theses may only be shared by linking to Carleton University Institutional Repository and no part may be used without proper attribution to the author. No part may be used for commercial purposes directly or indirectly via a for-profit platform; no adaptation or derivative works are permitted without consent from the copyright owner."]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.doi","label":"DOI","values":["10.22215/etd/2022-15430"]},{"key":"dc:identifier.uri","label":"Identifier URI","values":["https://hdl.handle.net/20.500.14718/42684"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["A novel ceramic matrix composite (CMC) system consisting of a commercially available SiC fibre, variations of electrophoretically deposited (EPD) fibre-matrix interphases, and a liquid metal melt infiltrated matrix was designed and characterised. A factorial design of experiments approach was undertaken to evaluate the deposition variables which would result in a functioning fibre-matrix interphase. A 25-2 partial factorial design matrix was selected with factors: electric potential, deposition time, surfactant, binder, and solids loading. The design matrix was replicated for four different EPD fibre-matrix interphase coating combinations: Al2O3/SiC, BN/PSZ, ZrC/ZTA, and SiC/Si3N4/SiC. Microcomposites were evaluated for tensile properties using a standard displacement controlled tensile test program. Microcomposites were tested at room temperature immediately following fabrication and following exposure to a standard atmosphere at 1000 °C for 1 h. Samples with ZrC/ZTA and SiC/Si3N4/SiC coatings demonstrated the best tensile properties in room temperature tests while samples with BN/PSZ and SiC/Si3N4/SiC coatings demonstrated the best retention of tensile properties following high temperature exposure. Subsequent SEM analysis revealed that coatings with smaller particle diameters as the inner layer of the fibre-matrix interphase coating produced more uniform coatings and the less fibre degradation due to oxidation following high temperature exposure. Additional microcomposites were fabricated for high temperature tensile testing; however, these samples were unable to bear recordable loads, an SEM examination revealed significant degradation of the matrix phase beneath the high temperature adhesive. Optical microscopy was used to evaluate coating thicknesses of coated fibre bundles prior to heat treatments. Measured coating thickness indicated that generally higher deposition times resulted in thicker coatings; however, coatings produced using 25 V electric potential were thicker than coatings produced using 12.5 V and 50 V electric potentials. This is likely due to a greater deposition efficiency factor at 25 V. FEA analysis was used to evaluate the electrical properties of an idealized version of the stationary EPD cell. This analysis showed a significant variation in the electric field along the fibre axis as well as a significant variation in electrical field between fibres in the centre of the fibre bundle and on the outer edge of the fibre bundle."]},{"key":"dc:title","label":"Title","values":["Design, Manufacturing, and Characterization of a Novel Ceramic Matrix Composite"]},{"key":"local:lac.licence","label":"Local Lac Licence","values":["true"]},{"key":"others:access_status","label":"Others Access Status","values":["open.access"]}]}],"canonical_facts":{"dc:creator":["Robertson, Taylor"],"dc:date.accessioned":["2025-04-08T20:42:09Z"],"dc:date.available":["2025-04-08T20:42:09Z"],"dc:date.issued":["2022"],"dc:description.abstract":["A novel ceramic matrix composite (CMC) system consisting of a commercially available SiC fibre, variations of electrophoretically deposited (EPD) fibre-matrix interphases, and a liquid metal melt infiltrated matrix was designed and characterised. A factorial design of experiments approach was undertaken to evaluate the deposition variables which would result in a functioning fibre-matrix interphase. A 25-2 partial factorial design matrix was selected with factors: electric potential, deposition time, surfactant, binder, and solids loading. The design matrix was replicated for four different EPD fibre-matrix interphase coating combinations: Al2O3/SiC, BN/PSZ, ZrC/ZTA, and SiC/Si3N4/SiC. Microcomposites were evaluated for tensile properties using a standard displacement controlled tensile test program. Microcomposites were tested at room temperature immediately following fabrication and following exposure to a standard atmosphere at 1000 °C for 1 h. Samples with ZrC/ZTA and SiC/Si3N4/SiC coatings demonstrated the best tensile properties in room temperature tests while samples with BN/PSZ and SiC/Si3N4/SiC coatings demonstrated the best retention of tensile properties following high temperature exposure. Subsequent SEM analysis revealed that coatings with smaller particle diameters as the inner layer of the fibre-matrix interphase coating produced more uniform coatings and the less fibre degradation due to oxidation following high temperature exposure. Additional microcomposites were fabricated for high temperature tensile testing; however, these samples were unable to bear recordable loads, an SEM examination revealed significant degradation of the matrix phase beneath the high temperature adhesive. Optical microscopy was used to evaluate coating thicknesses of coated fibre bundles prior to heat treatments. Measured coating thickness indicated that generally higher deposition times resulted in thicker coatings; however, coatings produced using 25 V electric potential were thicker than coatings produced using 12.5 V and 50 V electric potentials. This is likely due to a greater deposition efficiency factor at 25 V. FEA analysis was used to evaluate the electrical properties of an idealized version of the stationary EPD cell. This analysis showed a significant variation in the electric field along the fibre axis as well as a significant variation in electrical field between fibres in the centre of the fibre bundle and on the outer edge of the fibre bundle."],"dc:identifier.doi":["10.22215/etd/2022-15430"],"dc:identifier.uri":["https://hdl.handle.net/20.500.14718/42684"],"dc:language.iso":["en"],"dc:publisher":["Carleton University"],"dc:rights":["Copyright © 2022 the author(s). Theses may be used for non-commercial research, educational, or related academic purposes only. Such uses include personal study, research, scholarship, and teaching. Theses may only be shared by linking to Carleton University Institutional Repository and no part may be used without proper attribution to the author. No part may be used for commercial purposes directly or indirectly via a for-profit platform; no adaptation or derivative works are permitted without consent from the copyright owner."],"dc:subject.lcsh":["Mechanical engineering","Materials science"],"dc:title":["Design, Manufacturing, and Characterization of a Novel Ceramic Matrix Composite"],"dc:type":["thesis"],"local:lac.licence":["true"],"others:access_status":["open.access"],"thesis:degree_discipline":["Engineering, Mechanical"],"thesis:degree_level":["Doctoral"],"thesis:degree_name":["Doctor of Philosophy (Ph.D.)"]},"updated_at":"2026-11-19T07:08:56Z"}