{"id":{"repo_id":"carleton","oai_identifier":"oai:carleton.scholaris.ca:20.500.14718/42746"},"canonical_url":"https://search.ndltd.org/etd/carleton/oai:carleton.scholaris.ca:20.500.14718/42746","repository":{"repo_id":"carleton","name":"Carleton University","base_url":"https://carleton.scholaris.ca/server/oai/request"},"display":{"title":"Effects of shallow cover depth, corrosion and soil erosion on the mechanical performance of corrugated steel culverts","abstract":"Corrugated steel culverts (CSC) are key components of infrastructures to support water management and foundation integrity. Some installed culverts in North America are buried in shallow cover depths based on the engineering practices and they are exposed to environmental deteriorations in their service life. The primary goal of this research is to investigate the performance of corrugated steel culverts (CSC) buried subject to surface loads at shallow cover depths. The secondary goal of this research is to study environmental deterioration effects on the internal responses of CSC. Analytical models, finite element analysis (FEA) and numerical sensitivity studies are conducted to investigate the load transfer mechanisms and the development of internal CSC forces. The numerical results indicate that the complex geometry of the corrugated culvert subjects the crest and trough of corrugated profile to compression and tension due to the internal bending moment and thrust. These results indicate that the average strain response cannot account for the local peak strain response and this behavior necessitates corrections be applied to thrust calculations for buried culverts in shallow cover depth. The results achieved by sensitivity analysis indicates that the intact culvert/soil structure is an additive model and the thrust modification factor proposed for intact corrugated culverts buried in shallow cover depths. The impact of wall section loss due to corrosion is investigated and sensitivity analysis are used to identify variables that have a high impact and probability analysis conducted to predict the safety index and probability of failure of the corroded culvert buried in a shallow cover depth during the service life. The presence of soil voids, typically caused by erosion, is investigated by considering void size and position relative to the culvert. The study of void angle and void depth indicates that the loss of surface contact and support between the culvert and surrounding soil in the upper half of the culvert/soil structure is the key contributing factor to load transfer and deformation mechanisms.","abstract_html":"Corrugated steel culverts (CSC) are key components of infrastructures to support water management and foundation integrity. Some installed culverts in North America are buried in shallow cover depths based on the engineering practices and they are exposed to environmental deteriorations in their service life. The primary goal of this research is to investigate the performance of corrugated steel culverts (CSC) buried subject to surface loads at shallow cover depths. The secondary goal of this research is to study environmental deterioration effects on the internal responses of CSC. Analytical models, finite element analysis (FEA) and numerical sensitivity studies are conducted to investigate the load transfer mechanisms and the development of internal CSC forces. The numerical results indicate that the complex geometry of the corrugated culvert subjects the crest and trough of corrugated profile to compression and tension due to the internal bending moment and thrust. These results indicate that the average strain response cannot account for the local peak strain response and this behavior necessitates corrections be applied to thrust calculations for buried culverts in shallow cover depth. The results achieved by sensitivity analysis indicates that the intact culvert/soil structure is an additive model and the thrust modification factor proposed for intact corrugated culverts buried in shallow cover depths. The impact of wall section loss due to corrosion is investigated and sensitivity analysis are used to identify variables that have a high impact and probability analysis conducted to predict the safety index and probability of failure of the corroded culvert buried in a shallow cover depth during the service life. The presence of soil voids, typically caused by erosion, is investigated by considering void size and position relative to the culvert. The study of void angle and void depth indicates that the loss of surface contact and support between the culvert and surrounding soil in the upper half of the culvert/soil structure is the key contributing factor to load transfer and deformation mechanisms.","abstract_has_math":false,"creators":["Nakhostin, Elham"],"institution":"Carleton University","degree_name":"Doctor of Philosophy (Ph.D.)","degree_level":"Doctoral","degree_discipline":"Engineering, Civil","degree_department":null,"school":null,"contributors":[],"advisors":[],"committee_chairs":[],"committee_members":[],"year":2022,"date_issued":"2022","date_published":"2022","updated_at":"2026-11-19T07:07:37Z","subjects":["Civil engineering"],"languages":["en"],"rights":["Copyright © 2022 the author(s). Theses may be used for non-commercial research, educational, or related academic purposes only. Such uses include personal study, research, scholarship, and teaching. Theses may only be shared by linking to Carleton University Institutional Repository and no part may be used without proper attribution to the author. No part may be used for commercial purposes directly or indirectly via a for-profit platform; no adaptation or derivative works are permitted without consent from the copyright owner."],"rights_urls":[],"identifier_entries":[{"key":"dc:identifier.uri","label":"Identifier URI","values":["https://hdl.handle.net/20.500.14718/42746"],"render_values":[{"text":"https://hdl.handle.net/20.500.14718/42746","href":"https://hdl.handle.net/20.500.14718/42746","code":true}]}],"person_identifier_entries":[]},"links":{"outbound_url":"https://doi.org/10.22215/etd/2022-15018","outbound_label":"DOI","outbound_source":"dc:identifier.doi","record_url":"https://doi.org/10.22215/etd/2022-15018","record_label":"Repository record","record_kind":"doi","record_source":"dc:identifier.doi","access_status":null,"embargo_until":null,"access_note":null},"source_record":{"url":"https://carleton.scholaris.ca/server/oai/request?verb=GetRecord&metadataPrefix=dim&identifier=oai%3Acarleton.scholaris.ca%3A20.500.14718%2F42746","prefix":"dim"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:creator","label":"Author","values":["Nakhostin, Elham"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2025-04-08T20:43:22Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2025-04-08T20:43:22Z"]},{"key":"dc:date.issued","label":"Date","values":["2022"]},{"key":"dc:publisher","label":"Institution","values":["Carleton University"]},{"key":"dc:type","label":"Dc Type","values":["thesis"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Engineering, Civil"]},{"key":"thesis:degree_level","label":"Degree Level","values":["Doctoral"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Doctor of Philosophy (Ph.D.)"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject.lcsh","label":"Dc Subject Lcsh","values":["Civil engineering"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language.iso","label":"Language (ISO)","values":["en"]},{"key":"dc:rights","label":"Dc Rights","values":["Copyright © 2022 the author(s). Theses may be used for non-commercial research, educational, or related academic purposes only. Such uses include personal study, research, scholarship, and teaching. Theses may only be shared by linking to Carleton University Institutional Repository and no part may be used without proper attribution to the author. No part may be used for commercial purposes directly or indirectly via a for-profit platform; no adaptation or derivative works are permitted without consent from the copyright owner."]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.doi","label":"DOI","values":["10.22215/etd/2022-15018"]},{"key":"dc:identifier.uri","label":"Identifier URI","values":["https://hdl.handle.net/20.500.14718/42746"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["Corrugated steel culverts (CSC) are key components of infrastructures to support water management and foundation integrity. Some installed culverts in North America are buried in shallow cover depths based on the engineering practices and they are exposed to environmental deteriorations in their service life. The primary goal of this research is to investigate the performance of corrugated steel culverts (CSC) buried subject to surface loads at shallow cover depths. The secondary goal of this research is to study environmental deterioration effects on the internal responses of CSC. Analytical models, finite element analysis (FEA) and numerical sensitivity studies are conducted to investigate the load transfer mechanisms and the development of internal CSC forces. The numerical results indicate that the complex geometry of the corrugated culvert subjects the crest and trough of corrugated profile to compression and tension due to the internal bending moment and thrust. These results indicate that the average strain response cannot account for the local peak strain response and this behavior necessitates corrections be applied to thrust calculations for buried culverts in shallow cover depth. The results achieved by sensitivity analysis indicates that the intact culvert/soil structure is an additive model and the thrust modification factor proposed for intact corrugated culverts buried in shallow cover depths. The impact of wall section loss due to corrosion is investigated and sensitivity analysis are used to identify variables that have a high impact and probability analysis conducted to predict the safety index and probability of failure of the corroded culvert buried in a shallow cover depth during the service life. The presence of soil voids, typically caused by erosion, is investigated by considering void size and position relative to the culvert. The study of void angle and void depth indicates that the loss of surface contact and support between the culvert and surrounding soil in the upper half of the culvert/soil structure is the key contributing factor to load transfer and deformation mechanisms."]},{"key":"dc:title","label":"Title","values":["Effects of shallow cover depth, corrosion and soil erosion on the mechanical performance of corrugated steel culverts"]},{"key":"local:lac.licence","label":"Local Lac Licence","values":["true"]},{"key":"others:access_status","label":"Others Access Status","values":["open.access"]}]}],"canonical_facts":{"dc:creator":["Nakhostin, Elham"],"dc:date.accessioned":["2025-04-08T20:43:22Z"],"dc:date.available":["2025-04-08T20:43:22Z"],"dc:date.issued":["2022"],"dc:description.abstract":["Corrugated steel culverts (CSC) are key components of infrastructures to support water management and foundation integrity. Some installed culverts in North America are buried in shallow cover depths based on the engineering practices and they are exposed to environmental deteriorations in their service life. The primary goal of this research is to investigate the performance of corrugated steel culverts (CSC) buried subject to surface loads at shallow cover depths. The secondary goal of this research is to study environmental deterioration effects on the internal responses of CSC. Analytical models, finite element analysis (FEA) and numerical sensitivity studies are conducted to investigate the load transfer mechanisms and the development of internal CSC forces. The numerical results indicate that the complex geometry of the corrugated culvert subjects the crest and trough of corrugated profile to compression and tension due to the internal bending moment and thrust. These results indicate that the average strain response cannot account for the local peak strain response and this behavior necessitates corrections be applied to thrust calculations for buried culverts in shallow cover depth. The results achieved by sensitivity analysis indicates that the intact culvert/soil structure is an additive model and the thrust modification factor proposed for intact corrugated culverts buried in shallow cover depths. The impact of wall section loss due to corrosion is investigated and sensitivity analysis are used to identify variables that have a high impact and probability analysis conducted to predict the safety index and probability of failure of the corroded culvert buried in a shallow cover depth during the service life. The presence of soil voids, typically caused by erosion, is investigated by considering void size and position relative to the culvert. The study of void angle and void depth indicates that the loss of surface contact and support between the culvert and surrounding soil in the upper half of the culvert/soil structure is the key contributing factor to load transfer and deformation mechanisms."],"dc:identifier.doi":["10.22215/etd/2022-15018"],"dc:identifier.uri":["https://hdl.handle.net/20.500.14718/42746"],"dc:language.iso":["en"],"dc:publisher":["Carleton University"],"dc:rights":["Copyright © 2022 the author(s). Theses may be used for non-commercial research, educational, or related academic purposes only. Such uses include personal study, research, scholarship, and teaching. Theses may only be shared by linking to Carleton University Institutional Repository and no part may be used without proper attribution to the author. No part may be used for commercial purposes directly or indirectly via a for-profit platform; no adaptation or derivative works are permitted without consent from the copyright owner."],"dc:subject.lcsh":["Civil engineering"],"dc:title":["Effects of shallow cover depth, corrosion and soil erosion on the mechanical performance of corrugated steel culverts"],"dc:type":["thesis"],"local:lac.licence":["true"],"others:access_status":["open.access"],"thesis:degree_discipline":["Engineering, Civil"],"thesis:degree_level":["Doctoral"],"thesis:degree_name":["Doctor of Philosophy (Ph.D.)"]},"updated_at":"2026-11-19T07:07:37Z"}