{"id":{"repo_id":"carleton","oai_identifier":"oai:carleton.scholaris.ca:20.500.14718/42888"},"canonical_url":"https://search.ndltd.org/etd/carleton/oai:carleton.scholaris.ca:20.500.14718/42888","repository":{"repo_id":"carleton","name":"Carleton University","base_url":"https://carleton.scholaris.ca/server/oai/request"},"display":{"title":"Sensor System to Determine Force and Direction for Push Handles on Patient Transport System","abstract":"This Thesis presents the theory, development, and performance analysis of a novel force sensor system for the Able Innovations ALTATM patient transfer system. ALTATM is an alternative to slings, but it is heavy, and healthcare workers will require power assistance to move and position the system. Handles are provided for staff and the proposed sensor system measures the applied force magnitude and direction applied to these handles for use with motion assist motors. Load cell sensors, strain gauge sensors, proximity sensors and force sensitive resisters are considered and a solution using strain gauges is proposed that allows for the measurement of direction of force with minimal error without requiring detailed calibration of the sensors. Machine Learning comparing Logistic Regression, Linear Discriminant Analysis, Support Vector Machine, Decision Tree and Random Forest is tested to predict the angle and magnitude of the force with Decision Tree providing an accuracy of over 99%.","abstract_html":"This Thesis presents the theory, development, and performance analysis of a novel force sensor system for the Able Innovations ALTATM patient transfer system. ALTATM is an alternative to slings, but it is heavy, and healthcare workers will require power assistance to move and position the system. Handles are provided for staff and the proposed sensor system measures the applied force magnitude and direction applied to these handles for use with motion assist motors. Load cell sensors, strain gauge sensors, proximity sensors and force sensitive resisters are considered and a solution using strain gauges is proposed that allows for the measurement of direction of force with minimal error without requiring detailed calibration of the sensors. Machine Learning comparing Logistic Regression, Linear Discriminant Analysis, Support Vector Machine, Decision Tree and Random Forest is tested to predict the angle and magnitude of the force with Decision Tree providing an accuracy of over 99%.","abstract_has_math":false,"creators":["Chimehi, Bahareh"],"institution":"Carleton University","degree_name":"Master of Applied Science (M.App.Sc.)","degree_level":"Master's","degree_discipline":"Engineering, Biomedical","degree_department":null,"school":null,"contributors":[],"advisors":[],"committee_chairs":[],"committee_members":[],"year":2023,"date_issued":"2023","date_published":"2023","updated_at":"2026-11-19T07:13:35Z","subjects":["Biomedical engineering"],"languages":["en"],"rights":["Copyright © 2023 the author(s). Theses may be used for non-commercial research, educational, or related academic purposes only. Such uses include personal study, distribution to students, research and scholarship. Theses may only be shared by linking to the Carleton University Institutional Repository and no part may be copied without proper attribution to the author; no part may be used for commercial purposes directly or indirectly via a for-profit platform; no adaptation or derivative works are permitted without consent from the copyright owner."],"rights_urls":[],"identifier_entries":[{"key":"dc:identifier.doi","label":"DOI","values":["10.22215/etd/2023-15490"],"render_values":[{"text":"10.22215/etd/2023-15490","href":"https://doi.org/10.22215/etd/2023-15490","code":true}]}],"person_identifier_entries":[]},"links":{"outbound_url":"https://hdl.handle.net/20.500.14718/42888","outbound_label":"Handle","outbound_source":"dc:identifier.uri","record_url":"https://hdl.handle.net/20.500.14718/42888","record_label":"Repository record","record_kind":"handle","record_source":"dc:identifier.uri","download_url":null,"download_label":null,"download_source":null,"access_status":null,"embargo_until":null,"access_note":null},"source_record":{"url":"https://carleton.scholaris.ca/server/oai/request?verb=GetRecord&metadataPrefix=dim&identifier=oai%3Acarleton.scholaris.ca%3A20.500.14718%2F42888","prefix":"dim"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:creator","label":"Author","values":["Chimehi, Bahareh"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2025-04-08T20:45:55Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2025-04-08T20:45:55Z"]},{"key":"dc:date.issued","label":"Date","values":["2023"]},{"key":"dc:publisher","label":"Institution","values":["Carleton University"]},{"key":"dc:type","label":"Dc Type","values":["thesis"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Engineering, Biomedical"]},{"key":"thesis:degree_level","label":"Degree Level","values":["Master's"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Master of Applied Science (M.App.Sc.)"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject.lcsh","label":"Dc Subject Lcsh","values":["Biomedical engineering"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language.iso","label":"Language (ISO)","values":["en"]},{"key":"dc:rights","label":"Dc Rights","values":["Copyright © 2023 the author(s). Theses may be used for non-commercial research, educational, or related academic purposes only. Such uses include personal study, distribution to students, research and scholarship. Theses may only be shared by linking to the Carleton University Institutional Repository and no part may be copied without proper attribution to the author; no part may be used for commercial purposes directly or indirectly via a for-profit platform; no adaptation or derivative works are permitted without consent from the copyright owner."]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.doi","label":"DOI","values":["10.22215/etd/2023-15490"]},{"key":"dc:identifier.uri","label":"Identifier URI","values":["https://hdl.handle.net/20.500.14718/42888"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["This Thesis presents the theory, development, and performance analysis of a novel force sensor system for the Able Innovations ALTATM patient transfer system. ALTATM is an alternative to slings, but it is heavy, and healthcare workers will require power assistance to move and position the system. Handles are provided for staff and the proposed sensor system measures the applied force magnitude and direction applied to these handles for use with motion assist motors. Load cell sensors, strain gauge sensors, proximity sensors and force sensitive resisters are considered and a solution using strain gauges is proposed that allows for the measurement of direction of force with minimal error without requiring detailed calibration of the sensors. Machine Learning comparing Logistic Regression, Linear Discriminant Analysis, Support Vector Machine, Decision Tree and Random Forest is tested to predict the angle and magnitude of the force with Decision Tree providing an accuracy of over 99%."]},{"key":"dc:title","label":"Title","values":["Sensor System to Determine Force and Direction for Push Handles on Patient Transport System"]},{"key":"local:lac.licence","label":"Local Lac Licence","values":["true"]},{"key":"others:access_status","label":"Others Access Status","values":["open.access"]}]}],"canonical_facts":{"dc:creator":["Chimehi, Bahareh"],"dc:date.accessioned":["2025-04-08T20:45:55Z"],"dc:date.available":["2025-04-08T20:45:55Z"],"dc:date.issued":["2023"],"dc:description.abstract":["This Thesis presents the theory, development, and performance analysis of a novel force sensor system for the Able Innovations ALTATM patient transfer system. ALTATM is an alternative to slings, but it is heavy, and healthcare workers will require power assistance to move and position the system. Handles are provided for staff and the proposed sensor system measures the applied force magnitude and direction applied to these handles for use with motion assist motors. Load cell sensors, strain gauge sensors, proximity sensors and force sensitive resisters are considered and a solution using strain gauges is proposed that allows for the measurement of direction of force with minimal error without requiring detailed calibration of the sensors. Machine Learning comparing Logistic Regression, Linear Discriminant Analysis, Support Vector Machine, Decision Tree and Random Forest is tested to predict the angle and magnitude of the force with Decision Tree providing an accuracy of over 99%."],"dc:identifier.doi":["10.22215/etd/2023-15490"],"dc:identifier.uri":["https://hdl.handle.net/20.500.14718/42888"],"dc:language.iso":["en"],"dc:publisher":["Carleton University"],"dc:rights":["Copyright © 2023 the author(s). Theses may be used for non-commercial research, educational, or related academic purposes only. Such uses include personal study, distribution to students, research and scholarship. Theses may only be shared by linking to the Carleton University Institutional Repository and no part may be copied without proper attribution to the author; no part may be used for commercial purposes directly or indirectly via a for-profit platform; no adaptation or derivative works are permitted without consent from the copyright owner."],"dc:subject.lcsh":["Biomedical engineering"],"dc:title":["Sensor System to Determine Force and Direction for Push Handles on Patient Transport System"],"dc:type":["thesis"],"local:lac.licence":["true"],"others:access_status":["open.access"],"thesis:degree_discipline":["Engineering, Biomedical"],"thesis:degree_level":["Master's"],"thesis:degree_name":["Master of Applied Science (M.App.Sc.)"]},"updated_at":"2026-11-19T07:13:35Z"}