{"id":{"repo_id":"carleton","oai_identifier":"oai:carleton.scholaris.ca:20.500.14718/43052"},"canonical_url":"https://search.ndltd.org/etd/carleton/oai:carleton.scholaris.ca:20.500.14718/43052","repository":{"repo_id":"carleton","name":"Carleton University","base_url":"https://carleton.scholaris.ca/server/oai/request"},"display":{"title":"Toward Robust Automated Cardiovascular Arrhythmia Detection using Self-supervised Learning and 1-Dimensional Vision Transformers","abstract":"Cardiovascular diseases are the primary cause of death globally. With the prevalence of electrocardiogram machines, it is now possible to passively monitor a patient's heartbeat for cardiovascular diseases. However, the most significant problem currently prohibiting the wide-scale deployment of automated electrocardiogram systems is the potential for false alarms. Of the major culprits causing such issues, noise in the electrocardiogram data and label set can bias models to trigger unwanted alarms. Recently, as substantial amounts of unlabelled electrocardiogram data have become publicly available, self-supervision has emerged as a viable part of the pre-training process. This work begins by examining the importance of self-supervised learning for arrhythmia detection. A new method for self-supervised pre-training on electrocardiogram data is proposed, obtaining state-of-the-art results while simultaneously reducing the pre-training time by one-fifth and increasing the model's capacity by a factor of 14. Finally, this work investigates multiple solutions for addressing noise and class imbalance.","abstract_html":"Cardiovascular diseases are the primary cause of death globally. With the prevalence of electrocardiogram machines, it is now possible to passively monitor a patient&#x27;s heartbeat for cardiovascular diseases. However, the most significant problem currently prohibiting the wide-scale deployment of automated electrocardiogram systems is the potential for false alarms. Of the major culprits causing such issues, noise in the electrocardiogram data and label set can bias models to trigger unwanted alarms. Recently, as substantial amounts of unlabelled electrocardiogram data have become publicly available, self-supervision has emerged as a viable part of the pre-training process. This work begins by examining the importance of self-supervised learning for arrhythmia detection. A new method for self-supervised pre-training on electrocardiogram data is proposed, obtaining state-of-the-art results while simultaneously reducing the pre-training time by one-fifth and increasing the model&#x27;s capacity by a factor of 14. Finally, this work investigates multiple solutions for addressing noise and class imbalance.","abstract_has_math":false,"creators":["Chatterjee, Mitchell John Violini"],"institution":"Carleton University","degree_name":"Master of Computer Science (M.C.S.)","degree_level":"Master's","degree_discipline":"Computer Science","degree_department":null,"school":null,"contributors":[],"advisors":[],"committee_chairs":[],"committee_members":[],"year":2024,"date_issued":"2024","date_published":"2024","updated_at":"2026-11-19T07:08:35Z","subjects":["Computer science","Biomedical engineering"],"languages":["en"],"rights":["Copyright © 2024 the author(s). Theses may be used for non-commercial research, educational, or related academic purposes only. Such uses include personal study, distribution to students, research and scholarship. Theses may only be shared by linking to the Carleton University Institutional Repository and no part may be copied without proper attribution to the author; no part may be used for commercial purposes directly or indirectly via a for-profit platform; no adaptation or derivative works are permitted without consent from the copyright owner."],"rights_urls":[],"identifier_entries":[{"key":"dc:identifier.doi","label":"DOI","values":["10.22215/etd/2024-16267"],"render_values":[{"text":"10.22215/etd/2024-16267","href":"https://doi.org/10.22215/etd/2024-16267","code":true}]}],"person_identifier_entries":[]},"links":{"outbound_url":"https://hdl.handle.net/20.500.14718/43052","outbound_label":"Handle","outbound_source":"dc:identifier.uri","record_url":"https://hdl.handle.net/20.500.14718/43052","record_label":"Repository record","record_kind":"handle","record_source":"dc:identifier.uri","download_url":null,"download_label":null,"download_source":null,"access_status":null,"embargo_until":null,"access_note":null},"source_record":{"url":"https://carleton.scholaris.ca/server/oai/request?verb=GetRecord&metadataPrefix=dim&identifier=oai%3Acarleton.scholaris.ca%3A20.500.14718%2F43052","prefix":"dim"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:creator","label":"Author","values":["Chatterjee, Mitchell John Violini"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2025-04-08T20:48:40Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2025-04-08T20:48:40Z"]},{"key":"dc:date.issued","label":"Date","values":["2024"]},{"key":"dc:publisher","label":"Institution","values":["Carleton University"]},{"key":"dc:type","label":"Dc Type","values":["thesis"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Computer Science"]},{"key":"thesis:degree_level","label":"Degree Level","values":["Master's"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Master of Computer Science (M.C.S.)"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject.lcsh","label":"Dc Subject Lcsh","values":["Computer science","Biomedical engineering"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language.iso","label":"Language (ISO)","values":["en"]},{"key":"dc:rights","label":"Dc Rights","values":["Copyright © 2024 the author(s). Theses may be used for non-commercial research, educational, or related academic purposes only. Such uses include personal study, distribution to students, research and scholarship. Theses may only be shared by linking to the Carleton University Institutional Repository and no part may be copied without proper attribution to the author; no part may be used for commercial purposes directly or indirectly via a for-profit platform; no adaptation or derivative works are permitted without consent from the copyright owner."]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.doi","label":"DOI","values":["10.22215/etd/2024-16267"]},{"key":"dc:identifier.uri","label":"Identifier URI","values":["https://hdl.handle.net/20.500.14718/43052"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["Cardiovascular diseases are the primary cause of death globally. With the prevalence of electrocardiogram machines, it is now possible to passively monitor a patient's heartbeat for cardiovascular diseases. However, the most significant problem currently prohibiting the wide-scale deployment of automated electrocardiogram systems is the potential for false alarms. Of the major culprits causing such issues, noise in the electrocardiogram data and label set can bias models to trigger unwanted alarms. Recently, as substantial amounts of unlabelled electrocardiogram data have become publicly available, self-supervision has emerged as a viable part of the pre-training process. This work begins by examining the importance of self-supervised learning for arrhythmia detection. A new method for self-supervised pre-training on electrocardiogram data is proposed, obtaining state-of-the-art results while simultaneously reducing the pre-training time by one-fifth and increasing the model's capacity by a factor of 14. Finally, this work investigates multiple solutions for addressing noise and class imbalance."]},{"key":"dc:title","label":"Title","values":["Toward Robust Automated Cardiovascular Arrhythmia Detection using Self-supervised Learning and 1-Dimensional Vision Transformers"]},{"key":"local:lac.licence","label":"Local Lac Licence","values":["true"]},{"key":"others:access_status","label":"Others Access Status","values":["open.access"]}]}],"canonical_facts":{"dc:creator":["Chatterjee, Mitchell John Violini"],"dc:date.accessioned":["2025-04-08T20:48:40Z"],"dc:date.available":["2025-04-08T20:48:40Z"],"dc:date.issued":["2024"],"dc:description.abstract":["Cardiovascular diseases are the primary cause of death globally. With the prevalence of electrocardiogram machines, it is now possible to passively monitor a patient's heartbeat for cardiovascular diseases. However, the most significant problem currently prohibiting the wide-scale deployment of automated electrocardiogram systems is the potential for false alarms. Of the major culprits causing such issues, noise in the electrocardiogram data and label set can bias models to trigger unwanted alarms. Recently, as substantial amounts of unlabelled electrocardiogram data have become publicly available, self-supervision has emerged as a viable part of the pre-training process. This work begins by examining the importance of self-supervised learning for arrhythmia detection. A new method for self-supervised pre-training on electrocardiogram data is proposed, obtaining state-of-the-art results while simultaneously reducing the pre-training time by one-fifth and increasing the model's capacity by a factor of 14. Finally, this work investigates multiple solutions for addressing noise and class imbalance."],"dc:identifier.doi":["10.22215/etd/2024-16267"],"dc:identifier.uri":["https://hdl.handle.net/20.500.14718/43052"],"dc:language.iso":["en"],"dc:publisher":["Carleton University"],"dc:rights":["Copyright © 2024 the author(s). Theses may be used for non-commercial research, educational, or related academic purposes only. Such uses include personal study, distribution to students, research and scholarship. Theses may only be shared by linking to the Carleton University Institutional Repository and no part may be copied without proper attribution to the author; no part may be used for commercial purposes directly or indirectly via a for-profit platform; no adaptation or derivative works are permitted without consent from the copyright owner."],"dc:subject.lcsh":["Computer science","Biomedical engineering"],"dc:title":["Toward Robust Automated Cardiovascular Arrhythmia Detection using Self-supervised Learning and 1-Dimensional Vision Transformers"],"dc:type":["thesis"],"local:lac.licence":["true"],"others:access_status":["open.access"],"thesis:degree_discipline":["Computer Science"],"thesis:degree_level":["Master's"],"thesis:degree_name":["Master of Computer Science (M.C.S.)"]},"updated_at":"2026-11-19T07:08:35Z"}