{"id":{"repo_id":"carleton","oai_identifier":"oai:carleton.scholaris.ca:20.500.14718/43198"},"canonical_url":"https://search.ndltd.org/etd/carleton/oai:carleton.scholaris.ca:20.500.14718/43198","repository":{"repo_id":"carleton","name":"Carleton University","base_url":"https://carleton.scholaris.ca/server/oai/request"},"display":{"title":"Development of Panelized Exterior Retrofit Solutions for Commercial and Institutional Buildings","abstract":"The total energy used by commercial and institutional buildings in Canada is equivalent to over 10.7 million households. Exterior energy retrofits are over-cladding assemblies that are applied to the building envelope. These retrofits can drastically improve energy efficiency without the time consumption and disruptions of a conventional interior retrofit. This thesis evaluated two potential building envelope solutions for commercial and institutional buildings. One solution used primarily biogenic materials, and the other is based around an all-in-one building enclosure system. Test assemblies of both retrofits were built full-scale for long-term experimental testing. Both solutions provided significant improvements of thermal resistance compared to the original building assembly with little risk for failure at all measured locations. Similarly, modelled and experimental data showed overwhelming evidence that neither solution has potential for moisture damage and mould growth. The results indicate that either solution is viable for commercial and institutional building retrofits.","abstract_html":"The total energy used by commercial and institutional buildings in Canada is equivalent to over 10.7 million households. Exterior energy retrofits are over-cladding assemblies that are applied to the building envelope. These retrofits can drastically improve energy efficiency without the time consumption and disruptions of a conventional interior retrofit. This thesis evaluated two potential building envelope solutions for commercial and institutional buildings. One solution used primarily biogenic materials, and the other is based around an all-in-one building enclosure system. Test assemblies of both retrofits were built full-scale for long-term experimental testing. Both solutions provided significant improvements of thermal resistance compared to the original building assembly with little risk for failure at all measured locations. Similarly, modelled and experimental data showed overwhelming evidence that neither solution has potential for moisture damage and mould growth. The results indicate that either solution is viable for commercial and institutional building retrofits.","abstract_has_math":false,"creators":["Dalkowski, Thomas Michael"],"institution":"Carleton University","degree_name":"Master of Applied Science (M.App.Sc.)","degree_level":"Master's","degree_discipline":"Engineering, Mechanical","degree_department":null,"school":null,"contributors":[],"advisors":[],"committee_chairs":[],"committee_members":[],"year":2024,"date_issued":"2024","date_published":"2024","updated_at":"2026-11-19T07:00:21Z","subjects":["Materials science","Civil engineering","Mechanical engineering"],"languages":["en"],"rights":["Copyright © 2024 the author(s). Theses may be used for non-commercial research, educational, or related academic purposes only. Such uses include personal study, distribution to students, research and scholarship. Theses may only be shared by linking to the Carleton University Institutional Repository and no part may be copied without proper attribution to the author; no part may be used for commercial purposes directly or indirectly via a for-profit platform; no adaptation or derivative works are permitted without consent from the copyright owner."],"rights_urls":[],"identifier_entries":[{"key":"dc:identifier.uri","label":"Identifier URI","values":["https://hdl.handle.net/20.500.14718/43198"],"render_values":[{"text":"https://hdl.handle.net/20.500.14718/43198","href":"https://hdl.handle.net/20.500.14718/43198","code":true}]}],"person_identifier_entries":[]},"links":{"outbound_url":"https://doi.org/10.22215/etd/2024-16217","outbound_label":"DOI","outbound_source":"dc:identifier.doi","record_url":"https://doi.org/10.22215/etd/2024-16217","record_label":"Repository record","record_kind":"doi","record_source":"dc:identifier.doi","access_status":null,"embargo_until":null,"access_note":null},"oai_pmh_record":{"url":"https://union.ndltd.org/oai-pmh/?verb=GetRecord&metadataPrefix=oai_dc&identifier=oai%3Aunion.ndltd.org%3Arepo%3Acarleton%3Aoai%3Acarleton.scholaris.ca%3A20.500.14718%2F43198","prefix":"oai_dc"},"source_record":{"url":"https://carleton.scholaris.ca/server/oai/request?verb=GetRecord&metadataPrefix=dim&identifier=oai%3Acarleton.scholaris.ca%3A20.500.14718%2F43198","prefix":"dim"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:creator","label":"Author","values":["Dalkowski, Thomas Michael"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2025-04-08T20:51:28Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2025-04-08T20:51:28Z"]},{"key":"dc:date.issued","label":"Date","values":["2024"]},{"key":"dc:publisher","label":"Institution","values":["Carleton University"]},{"key":"dc:type","label":"Dc Type","values":["thesis"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Engineering, Mechanical"]},{"key":"thesis:degree_level","label":"Degree Level","values":["Master's"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Master of Applied Science (M.App.Sc.)"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject.lcsh","label":"Dc Subject Lcsh","values":["Materials science","Civil engineering","Mechanical engineering"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language.iso","label":"Language (ISO)","values":["en"]},{"key":"dc:rights","label":"Dc Rights","values":["Copyright © 2024 the author(s). Theses may be used for non-commercial research, educational, or related academic purposes only. Such uses include personal study, distribution to students, research and scholarship. Theses may only be shared by linking to the Carleton University Institutional Repository and no part may be copied without proper attribution to the author; no part may be used for commercial purposes directly or indirectly via a for-profit platform; no adaptation or derivative works are permitted without consent from the copyright owner."]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.doi","label":"DOI","values":["10.22215/etd/2024-16217"]},{"key":"dc:identifier.uri","label":"Identifier URI","values":["https://hdl.handle.net/20.500.14718/43198"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["The total energy used by commercial and institutional buildings in Canada is equivalent to over 10.7 million households. Exterior energy retrofits are over-cladding assemblies that are applied to the building envelope. These retrofits can drastically improve energy efficiency without the time consumption and disruptions of a conventional interior retrofit. This thesis evaluated two potential building envelope solutions for commercial and institutional buildings. One solution used primarily biogenic materials, and the other is based around an all-in-one building enclosure system. Test assemblies of both retrofits were built full-scale for long-term experimental testing. Both solutions provided significant improvements of thermal resistance compared to the original building assembly with little risk for failure at all measured locations. Similarly, modelled and experimental data showed overwhelming evidence that neither solution has potential for moisture damage and mould growth. The results indicate that either solution is viable for commercial and institutional building retrofits."]},{"key":"dc:title","label":"Title","values":["Development of Panelized Exterior Retrofit Solutions for Commercial and Institutional Buildings"]},{"key":"local:lac.licence","label":"Local Lac Licence","values":["true"]},{"key":"others:access_status","label":"Others Access Status","values":["open.access"]}]}],"canonical_facts":{"dc:creator":["Dalkowski, Thomas Michael"],"dc:date.accessioned":["2025-04-08T20:51:28Z"],"dc:date.available":["2025-04-08T20:51:28Z"],"dc:date.issued":["2024"],"dc:description.abstract":["The total energy used by commercial and institutional buildings in Canada is equivalent to over 10.7 million households. Exterior energy retrofits are over-cladding assemblies that are applied to the building envelope. These retrofits can drastically improve energy efficiency without the time consumption and disruptions of a conventional interior retrofit. This thesis evaluated two potential building envelope solutions for commercial and institutional buildings. One solution used primarily biogenic materials, and the other is based around an all-in-one building enclosure system. Test assemblies of both retrofits were built full-scale for long-term experimental testing. Both solutions provided significant improvements of thermal resistance compared to the original building assembly with little risk for failure at all measured locations. Similarly, modelled and experimental data showed overwhelming evidence that neither solution has potential for moisture damage and mould growth. The results indicate that either solution is viable for commercial and institutional building retrofits."],"dc:identifier.doi":["10.22215/etd/2024-16217"],"dc:identifier.uri":["https://hdl.handle.net/20.500.14718/43198"],"dc:language.iso":["en"],"dc:publisher":["Carleton University"],"dc:rights":["Copyright © 2024 the author(s). Theses may be used for non-commercial research, educational, or related academic purposes only. Such uses include personal study, distribution to students, research and scholarship. Theses may only be shared by linking to the Carleton University Institutional Repository and no part may be copied without proper attribution to the author; no part may be used for commercial purposes directly or indirectly via a for-profit platform; no adaptation or derivative works are permitted without consent from the copyright owner."],"dc:subject.lcsh":["Materials science","Civil engineering","Mechanical engineering"],"dc:title":["Development of Panelized Exterior Retrofit Solutions for Commercial and Institutional Buildings"],"dc:type":["thesis"],"local:lac.licence":["true"],"others:access_status":["open.access"],"thesis:degree_discipline":["Engineering, Mechanical"],"thesis:degree_level":["Master's"],"thesis:degree_name":["Master of Applied Science (M.App.Sc.)"]},"updated_at":"2026-11-19T07:00:21Z"}