{"id":{"repo_id":"carleton","oai_identifier":"oai:carleton.scholaris.ca:20.500.14718/43213"},"canonical_url":"https://search.ndltd.org/etd/carleton/oai:carleton.scholaris.ca:20.500.14718/43213","repository":{"repo_id":"carleton","name":"Carleton University","base_url":"https://carleton.scholaris.ca/server/oai/request"},"display":{"title":"Human Activity and Posture Classification Using Single Non-Contact Radar Sensor","abstract":"Radar has been proposed for monitoring the health of elderly patients in long term care because it is safe, non-contact and preserves the privacy of patients. Random body movements (RBM) obscure radar return signals making it difficult if not impossible to accurately estimate vitals. Activity classification is presented in this thesis as a pre-processing step for dealing with RBMs. Posture classification is presented in this thesis for assistance in preventing falls. Two popular radar architectures- continuous wave (CW) Doppler and ultra-wideband (UWB) are investigated in this thesis. Activity classification is performed with 92% average accuracy with CW and 86% with UWB. Posture Classification is performed with 64% average accuracy with CW and 85% with UWB. An occupancy detection algorithm was also developed for UWB and achieved 88% average accuracy. The contribution of this thesis is a proposed hierarchical processing approach for both radar types capable of dealing with moving subjects.","abstract_html":"Radar has been proposed for monitoring the health of elderly patients in long term care because it is safe, non-contact and preserves the privacy of patients. Random body movements (RBM) obscure radar return signals making it difficult if not impossible to accurately estimate vitals. Activity classification is presented in this thesis as a pre-processing step for dealing with RBMs. Posture classification is presented in this thesis for assistance in preventing falls. Two popular radar architectures- continuous wave (CW) Doppler and ultra-wideband (UWB) are investigated in this thesis. Activity classification is performed with 92% average accuracy with CW and 86% with UWB. Posture Classification is performed with 64% average accuracy with CW and 85% with UWB. An occupancy detection algorithm was also developed for UWB and achieved 88% average accuracy. The contribution of this thesis is a proposed hierarchical processing approach for both radar types capable of dealing with moving subjects.","abstract_has_math":false,"creators":["Baird, Zachary"],"institution":"Carleton University","degree_name":"Master of Applied Science (M.App.Sc.)","degree_level":"Master's","degree_discipline":"Engineering, Electrical and Computer","degree_department":null,"school":null,"contributors":[],"advisors":[],"committee_chairs":[],"committee_members":[],"year":2017,"date_issued":"2017","date_published":"2017","updated_at":"2026-11-19T07:15:44Z","subjects":["System theory","Electrical engineering","System analysis","Electric networks","Biomedical engineering"],"languages":["en"],"rights":["Copyright © 2017 the author(s). Theses may be used for non-commercial research, educational, or related academic purposes only. Such uses include personal study, research, scholarship, and teaching. Theses may only be shared by linking to Carleton University Institutional Repository and no part may be used without proper attribution to the author. No part may be used for commercial purposes directly or indirectly via a for-profit platform; no adaptation or derivative works are permitted without consent from the copyright owner."],"rights_urls":[],"identifier_entries":[{"key":"dc:identifier.uri","label":"Identifier URI","values":["https://hdl.handle.net/20.500.14718/43213"],"render_values":[{"text":"https://hdl.handle.net/20.500.14718/43213","href":"https://hdl.handle.net/20.500.14718/43213","code":true}]}],"person_identifier_entries":[]},"links":{"outbound_url":"https://doi.org/10.22215/etd/2017-12170","outbound_label":"DOI","outbound_source":"dc:identifier.doi","record_url":"https://doi.org/10.22215/etd/2017-12170","record_label":"Repository record","record_kind":"doi","record_source":"dc:identifier.doi","access_status":null,"embargo_until":null,"access_note":null},"oai_pmh_record":{"url":"https://union.ndltd.org/oai-pmh/?verb=GetRecord&metadataPrefix=oai_dc&identifier=oai%3Aunion.ndltd.org%3Arepo%3Acarleton%3Aoai%3Acarleton.scholaris.ca%3A20.500.14718%2F43213","prefix":"oai_dc"},"source_record":{"url":"https://carleton.scholaris.ca/server/oai/request?verb=GetRecord&metadataPrefix=dim&identifier=oai%3Acarleton.scholaris.ca%3A20.500.14718%2F43213","prefix":"dim"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:creator","label":"Author","values":["Baird, Zachary"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2025-04-08T20:51:44Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2025-04-08T20:51:44Z"]},{"key":"dc:date.issued","label":"Date","values":["2017"]},{"key":"dc:publisher","label":"Institution","values":["Carleton University"]},{"key":"dc:type","label":"Dc Type","values":["thesis"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Engineering, Electrical and Computer"]},{"key":"thesis:degree_level","label":"Degree Level","values":["Master's"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Master of Applied Science (M.App.Sc.)"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject.lcsh","label":"Dc Subject Lcsh","values":["System theory","Electrical engineering","System analysis","Electric networks","Biomedical engineering"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language.iso","label":"Language (ISO)","values":["en"]},{"key":"dc:rights","label":"Dc Rights","values":["Copyright © 2017 the author(s). Theses may be used for non-commercial research, educational, or related academic purposes only. Such uses include personal study, research, scholarship, and teaching. Theses may only be shared by linking to Carleton University Institutional Repository and no part may be used without proper attribution to the author. No part may be used for commercial purposes directly or indirectly via a for-profit platform; no adaptation or derivative works are permitted without consent from the copyright owner."]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.doi","label":"DOI","values":["10.22215/etd/2017-12170"]},{"key":"dc:identifier.uri","label":"Identifier URI","values":["https://hdl.handle.net/20.500.14718/43213"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["Radar has been proposed for monitoring the health of elderly patients in long term care because it is safe, non-contact and preserves the privacy of patients. Random body movements (RBM) obscure radar return signals making it difficult if not impossible to accurately estimate vitals. Activity classification is presented in this thesis as a pre-processing step for dealing with RBMs. Posture classification is presented in this thesis for assistance in preventing falls. Two popular radar architectures- continuous wave (CW) Doppler and ultra-wideband (UWB) are investigated in this thesis. Activity classification is performed with 92% average accuracy with CW and 86% with UWB. Posture Classification is performed with 64% average accuracy with CW and 85% with UWB. An occupancy detection algorithm was also developed for UWB and achieved 88% average accuracy. The contribution of this thesis is a proposed hierarchical processing approach for both radar types capable of dealing with moving subjects."]},{"key":"dc:title","label":"Title","values":["Human Activity and Posture Classification Using Single Non-Contact Radar Sensor"]},{"key":"local:lac.licence","label":"Local Lac Licence","values":["true"]},{"key":"others:access_status","label":"Others Access Status","values":["open.access"]}]}],"canonical_facts":{"dc:creator":["Baird, Zachary"],"dc:date.accessioned":["2025-04-08T20:51:44Z"],"dc:date.available":["2025-04-08T20:51:44Z"],"dc:date.issued":["2017"],"dc:description.abstract":["Radar has been proposed for monitoring the health of elderly patients in long term care because it is safe, non-contact and preserves the privacy of patients. Random body movements (RBM) obscure radar return signals making it difficult if not impossible to accurately estimate vitals. Activity classification is presented in this thesis as a pre-processing step for dealing with RBMs. Posture classification is presented in this thesis for assistance in preventing falls. Two popular radar architectures- continuous wave (CW) Doppler and ultra-wideband (UWB) are investigated in this thesis. Activity classification is performed with 92% average accuracy with CW and 86% with UWB. Posture Classification is performed with 64% average accuracy with CW and 85% with UWB. An occupancy detection algorithm was also developed for UWB and achieved 88% average accuracy. The contribution of this thesis is a proposed hierarchical processing approach for both radar types capable of dealing with moving subjects."],"dc:identifier.doi":["10.22215/etd/2017-12170"],"dc:identifier.uri":["https://hdl.handle.net/20.500.14718/43213"],"dc:language.iso":["en"],"dc:publisher":["Carleton University"],"dc:rights":["Copyright © 2017 the author(s). Theses may be used for non-commercial research, educational, or related academic purposes only. Such uses include personal study, research, scholarship, and teaching. Theses may only be shared by linking to Carleton University Institutional Repository and no part may be used without proper attribution to the author. No part may be used for commercial purposes directly or indirectly via a for-profit platform; no adaptation or derivative works are permitted without consent from the copyright owner."],"dc:subject.lcsh":["System theory","Electrical engineering","System analysis","Electric networks","Biomedical engineering"],"dc:title":["Human Activity and Posture Classification Using Single Non-Contact Radar Sensor"],"dc:type":["thesis"],"local:lac.licence":["true"],"others:access_status":["open.access"],"thesis:degree_discipline":["Engineering, Electrical and Computer"],"thesis:degree_level":["Master's"],"thesis:degree_name":["Master of Applied Science (M.App.Sc.)"]},"updated_at":"2026-11-19T07:15:44Z"}