{"id":{"repo_id":"carleton","oai_identifier":"oai:carleton.scholaris.ca:20.500.14718/43318"},"canonical_url":"https://search.ndltd.org/etd/carleton/oai:carleton.scholaris.ca:20.500.14718/43318","repository":{"repo_id":"carleton","name":"Carleton University","base_url":"https://carleton.scholaris.ca/server/oai/request"},"display":{"title":"Motion Artifact Data to Facilitate Bioelectric Signal Quality Analysis Research","abstract":"Bioelectric signal quality analysis is important to address the challenges associated with contaminants, including motion artifacts. However, the limited availability of motion artifact data poses a challenge in developing and evaluating new tools (e.g., biases due to signal reuse). This research expands motion artifact data through two approaches. First, we deployed a Motion Artifact Signal Generation Toolkit to synthesize motion artifacts using Autoregressive, Markov Chain, and Recurrent Neural Network models. We extend model validation to non-cyclical motion artifacts. Second, we estimate motion artifacts in long-term ECG recordings using a template subtraction method, creating a motion artifact database of 84 signals. Additionally, we explore time-series segmentation of motion artifacts, leveraging a clustering pipeline, including k-means clustering, to partition long-term recordings based on signal statistics and attributes. These contributions greatly expand the public availability of motion artifacts for biomedical signal quality analysis researchers to use worldwide.","abstract_html":"Bioelectric signal quality analysis is important to address the challenges associated with contaminants, including motion artifacts. However, the limited availability of motion artifact data poses a challenge in developing and evaluating new tools (e.g., biases due to signal reuse). This research expands motion artifact data through two approaches. First, we deployed a Motion Artifact Signal Generation Toolkit to synthesize motion artifacts using Autoregressive, Markov Chain, and Recurrent Neural Network models. We extend model validation to non-cyclical motion artifacts. Second, we estimate motion artifacts in long-term ECG recordings using a template subtraction method, creating a motion artifact database of 84 signals. Additionally, we explore time-series segmentation of motion artifacts, leveraging a clustering pipeline, including k-means clustering, to partition long-term recordings based on signal statistics and attributes. These contributions greatly expand the public availability of motion artifacts for biomedical signal quality analysis researchers to use worldwide.","abstract_has_math":false,"creators":["Kulpa, Jonathan Adam"],"institution":"Carleton University","degree_name":"Master of Applied Science (M.App.Sc.)","degree_level":"Master's","degree_discipline":"Engineering, Biomedical","degree_department":null,"school":null,"contributors":[],"advisors":[],"committee_chairs":[],"committee_members":[],"year":2024,"date_issued":"2024","date_published":"2024","updated_at":"2026-11-19T07:00:05Z","subjects":["Biomedical engineering"],"languages":["en"],"rights":["Copyright © 2023 the author(s). Theses may be used for non-commercial research, educational, or related academic purposes only. Such uses include personal study, distribution to students, research and scholarship. Theses may only be shared by linking to the Carleton University Institutional Repository and no part may be copied without proper attribution to the author; no part may be used for commercial purposes directly or indirectly via a for-profit platform; no adaptation or derivative works are permitted without consent from the copyright owner."],"rights_urls":[],"identifier_entries":[{"key":"dc:identifier.doi","label":"DOI","values":["10.22215/etd/2023-16100"],"render_values":[{"text":"10.22215/etd/2023-16100","href":"https://doi.org/10.22215/etd/2023-16100","code":true}]}],"person_identifier_entries":[]},"links":{"outbound_url":"https://hdl.handle.net/20.500.14718/43318","outbound_label":"Handle","outbound_source":"dc:identifier.uri","record_url":"https://hdl.handle.net/20.500.14718/43318","record_label":"Repository record","record_kind":"handle","record_source":"dc:identifier.uri","download_url":null,"download_label":null,"download_source":null,"access_status":null,"embargo_until":null,"access_note":null},"source_record":{"url":"https://carleton.scholaris.ca/server/oai/request?verb=GetRecord&metadataPrefix=dim&identifier=oai%3Acarleton.scholaris.ca%3A20.500.14718%2F43318","prefix":"dim"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:creator","label":"Author","values":["Kulpa, Jonathan Adam"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2025-04-08T20:54:32Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2025-04-08T20:54:32Z"]},{"key":"dc:date.issued","label":"Date","values":["2024"]},{"key":"dc:publisher","label":"Institution","values":["Carleton University"]},{"key":"dc:type","label":"Dc Type","values":["thesis"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Engineering, Biomedical"]},{"key":"thesis:degree_level","label":"Degree Level","values":["Master's"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Master of Applied Science (M.App.Sc.)"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject.lcsh","label":"Dc Subject Lcsh","values":["Biomedical engineering"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language.iso","label":"Language (ISO)","values":["en"]},{"key":"dc:rights","label":"Dc Rights","values":["Copyright © 2023 the author(s). Theses may be used for non-commercial research, educational, or related academic purposes only. Such uses include personal study, distribution to students, research and scholarship. Theses may only be shared by linking to the Carleton University Institutional Repository and no part may be copied without proper attribution to the author; no part may be used for commercial purposes directly or indirectly via a for-profit platform; no adaptation or derivative works are permitted without consent from the copyright owner."]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.doi","label":"DOI","values":["10.22215/etd/2023-16100"]},{"key":"dc:identifier.uri","label":"Identifier URI","values":["https://hdl.handle.net/20.500.14718/43318"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["Bioelectric signal quality analysis is important to address the challenges associated with contaminants, including motion artifacts. However, the limited availability of motion artifact data poses a challenge in developing and evaluating new tools (e.g., biases due to signal reuse). This research expands motion artifact data through two approaches. First, we deployed a Motion Artifact Signal Generation Toolkit to synthesize motion artifacts using Autoregressive, Markov Chain, and Recurrent Neural Network models. We extend model validation to non-cyclical motion artifacts. Second, we estimate motion artifacts in long-term ECG recordings using a template subtraction method, creating a motion artifact database of 84 signals. Additionally, we explore time-series segmentation of motion artifacts, leveraging a clustering pipeline, including k-means clustering, to partition long-term recordings based on signal statistics and attributes. These contributions greatly expand the public availability of motion artifacts for biomedical signal quality analysis researchers to use worldwide."]},{"key":"dc:title","label":"Title","values":["Motion Artifact Data to Facilitate Bioelectric Signal Quality Analysis Research"]},{"key":"local:lac.licence","label":"Local Lac Licence","values":["true"]},{"key":"others:access_status","label":"Others Access Status","values":["open.access"]}]}],"canonical_facts":{"dc:creator":["Kulpa, Jonathan Adam"],"dc:date.accessioned":["2025-04-08T20:54:32Z"],"dc:date.available":["2025-04-08T20:54:32Z"],"dc:date.issued":["2024"],"dc:description.abstract":["Bioelectric signal quality analysis is important to address the challenges associated with contaminants, including motion artifacts. However, the limited availability of motion artifact data poses a challenge in developing and evaluating new tools (e.g., biases due to signal reuse). This research expands motion artifact data through two approaches. First, we deployed a Motion Artifact Signal Generation Toolkit to synthesize motion artifacts using Autoregressive, Markov Chain, and Recurrent Neural Network models. We extend model validation to non-cyclical motion artifacts. Second, we estimate motion artifacts in long-term ECG recordings using a template subtraction method, creating a motion artifact database of 84 signals. Additionally, we explore time-series segmentation of motion artifacts, leveraging a clustering pipeline, including k-means clustering, to partition long-term recordings based on signal statistics and attributes. These contributions greatly expand the public availability of motion artifacts for biomedical signal quality analysis researchers to use worldwide."],"dc:identifier.doi":["10.22215/etd/2023-16100"],"dc:identifier.uri":["https://hdl.handle.net/20.500.14718/43318"],"dc:language.iso":["en"],"dc:publisher":["Carleton University"],"dc:rights":["Copyright © 2023 the author(s). Theses may be used for non-commercial research, educational, or related academic purposes only. Such uses include personal study, distribution to students, research and scholarship. Theses may only be shared by linking to the Carleton University Institutional Repository and no part may be copied without proper attribution to the author; no part may be used for commercial purposes directly or indirectly via a for-profit platform; no adaptation or derivative works are permitted without consent from the copyright owner."],"dc:subject.lcsh":["Biomedical engineering"],"dc:title":["Motion Artifact Data to Facilitate Bioelectric Signal Quality Analysis Research"],"dc:type":["thesis"],"local:lac.licence":["true"],"others:access_status":["open.access"],"thesis:degree_discipline":["Engineering, Biomedical"],"thesis:degree_level":["Master's"],"thesis:degree_name":["Master of Applied Science (M.App.Sc.)"]},"updated_at":"2026-11-19T07:00:05Z"}