{"id":{"repo_id":"carleton","oai_identifier":"oai:carleton.scholaris.ca:20.500.14718/43637"},"canonical_url":"https://search.ndltd.org/etd/carleton/oai:carleton.scholaris.ca:20.500.14718/43637","repository":{"repo_id":"carleton","name":"Carleton University","base_url":"https://carleton.scholaris.ca/server/oai/request"},"display":{"title":"Separating the vascular and nonvascular sources of magnetic susceptibility in physiological MRI techniques based on the reversible transverse relaxation rate, R2’","abstract":"The blood oxygenation level-dependent (BOLD) signal is the most common functional MRI technique for mapping human brain organization. It is a qualitative measure that reflects changes in oxygen metabolism and blood flow driven by changes in brain activity. Various techniques exist to quantify physiological parameters underlying the BOLD signal, primarily based on relating them to the transverse relaxation rates. Quantitative susceptibility maps measured in subjects at rest and during a hypercapnic challenge were used to determine how much vasculature contributes to magnetic susceptibility compared to other tissues. Iso-oxygen saturation maps show the apparent oxygen saturation of blood where the susceptibility of blood and surrounding non-blood tissue would be equivalent, it is closer to 0.9. Non-blood susceptibility creates bias in quantifying oxygen metabolism in gas-free calibrated BOLD and quantitative BOLD. Iso-oxygen saturation of blood was found to be lower in deeper cortical tissue and to negatively correlate with non-heme iron concentration.","abstract_html":"The blood oxygenation level-dependent (BOLD) signal is the most common functional MRI technique for mapping human brain organization. It is a qualitative measure that reflects changes in oxygen metabolism and blood flow driven by changes in brain activity. Various techniques exist to quantify physiological parameters underlying the BOLD signal, primarily based on relating them to the transverse relaxation rates. Quantitative susceptibility maps measured in subjects at rest and during a hypercapnic challenge were used to determine how much vasculature contributes to magnetic susceptibility compared to other tissues. Iso-oxygen saturation maps show the apparent oxygen saturation of blood where the susceptibility of blood and surrounding non-blood tissue would be equivalent, it is closer to 0.9. Non-blood susceptibility creates bias in quantifying oxygen metabolism in gas-free calibrated BOLD and quantitative BOLD. Iso-oxygen saturation of blood was found to be lower in deeper cortical tissue and to negatively correlate with non-heme iron concentration.","abstract_has_math":false,"creators":["Anderson, Eva Theodora Elizabeth"],"institution":"Carleton University","degree_name":"Master of Science (M.Sc.)","degree_level":"Master's","degree_discipline":"Physics","degree_department":null,"school":null,"contributors":[],"advisors":[],"committee_chairs":[],"committee_members":[],"year":2025,"date_issued":"2025","date_published":"2025","updated_at":"2026-11-19T07:02:57Z","subjects":["Physics"],"languages":["en"],"rights":["Copyright © 2024 the author(s). Theses may be used for non-commercial research, educational, or related academic purposes only. Such uses include personal study, distribution to students, research and scholarship. Theses may only be shared by linking to the Carleton University Institutional Repository and no part may be copied without proper attribution to the author; no part may be used for commercial purposes directly or indirectly via a for-profit platform; no adaptation or derivative works are permitted without consent from the copyright owner."],"rights_urls":[],"identifier_entries":[{"key":"dc:identifier.doi","label":"DOI","values":["10.22215/etd/2025-16494"],"render_values":[{"text":"10.22215/etd/2025-16494","href":"https://doi.org/10.22215/etd/2025-16494","code":true}]}],"person_identifier_entries":[]},"links":{"outbound_url":"https://hdl.handle.net/20.500.14718/43637","outbound_label":"Handle","outbound_source":"dc:identifier.uri","record_url":"https://hdl.handle.net/20.500.14718/43637","record_label":"Repository record","record_kind":"handle","record_source":"dc:identifier.uri","download_url":null,"download_label":null,"download_source":null,"access_status":null,"embargo_until":null,"access_note":null},"source_record":{"url":"https://carleton.scholaris.ca/server/oai/request?verb=GetRecord&metadataPrefix=dim&identifier=oai%3Acarleton.scholaris.ca%3A20.500.14718%2F43637","prefix":"dim"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:creator","label":"Author","values":["Anderson, Eva Theodora Elizabeth"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2025-05-23T20:05:39Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2025-05-23T20:05:39Z"]},{"key":"dc:date.issued","label":"Date","values":["2025"]},{"key":"dc:publisher","label":"Institution","values":["Carleton University"]},{"key":"dc:type","label":"Dc Type","values":["thesis"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Physics"]},{"key":"thesis:degree_level","label":"Degree Level","values":["Master's"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Master of Science (M.Sc.)"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject.lcsh","label":"Dc Subject Lcsh","values":["Physics"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language.iso","label":"Language (ISO)","values":["en"]},{"key":"dc:rights","label":"Dc Rights","values":["Copyright © 2024 the author(s). Theses may be used for non-commercial research, educational, or related academic purposes only. Such uses include personal study, distribution to students, research and scholarship. Theses may only be shared by linking to the Carleton University Institutional Repository and no part may be copied without proper attribution to the author; no part may be used for commercial purposes directly or indirectly via a for-profit platform; no adaptation or derivative works are permitted without consent from the copyright owner."]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.doi","label":"DOI","values":["10.22215/etd/2025-16494"]},{"key":"dc:identifier.uri","label":"Identifier URI","values":["https://hdl.handle.net/20.500.14718/43637"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["The blood oxygenation level-dependent (BOLD) signal is the most common functional MRI technique for mapping human brain organization. It is a qualitative measure that reflects changes in oxygen metabolism and blood flow driven by changes in brain activity. Various techniques exist to quantify physiological parameters underlying the BOLD signal, primarily based on relating them to the transverse relaxation rates. Quantitative susceptibility maps measured in subjects at rest and during a hypercapnic challenge were used to determine how much vasculature contributes to magnetic susceptibility compared to other tissues. Iso-oxygen saturation maps show the apparent oxygen saturation of blood where the susceptibility of blood and surrounding non-blood tissue would be equivalent, it is closer to 0.9. Non-blood susceptibility creates bias in quantifying oxygen metabolism in gas-free calibrated BOLD and quantitative BOLD. Iso-oxygen saturation of blood was found to be lower in deeper cortical tissue and to negatively correlate with non-heme iron concentration."]},{"key":"dc:title","label":"Title","values":["Separating the vascular and nonvascular sources of magnetic susceptibility in physiological MRI techniques based on the reversible transverse relaxation rate, R2’"]},{"key":"local:lac.licence","label":"Local Lac Licence","values":["true"]},{"key":"others:access_status","label":"Others Access Status","values":["open.access"]}]}],"canonical_facts":{"dc:creator":["Anderson, Eva Theodora Elizabeth"],"dc:date.accessioned":["2025-05-23T20:05:39Z"],"dc:date.available":["2025-05-23T20:05:39Z"],"dc:date.issued":["2025"],"dc:description.abstract":["The blood oxygenation level-dependent (BOLD) signal is the most common functional MRI technique for mapping human brain organization. It is a qualitative measure that reflects changes in oxygen metabolism and blood flow driven by changes in brain activity. Various techniques exist to quantify physiological parameters underlying the BOLD signal, primarily based on relating them to the transverse relaxation rates. Quantitative susceptibility maps measured in subjects at rest and during a hypercapnic challenge were used to determine how much vasculature contributes to magnetic susceptibility compared to other tissues. Iso-oxygen saturation maps show the apparent oxygen saturation of blood where the susceptibility of blood and surrounding non-blood tissue would be equivalent, it is closer to 0.9. Non-blood susceptibility creates bias in quantifying oxygen metabolism in gas-free calibrated BOLD and quantitative BOLD. Iso-oxygen saturation of blood was found to be lower in deeper cortical tissue and to negatively correlate with non-heme iron concentration."],"dc:identifier.doi":["10.22215/etd/2025-16494"],"dc:identifier.uri":["https://hdl.handle.net/20.500.14718/43637"],"dc:language.iso":["en"],"dc:publisher":["Carleton University"],"dc:rights":["Copyright © 2024 the author(s). Theses may be used for non-commercial research, educational, or related academic purposes only. Such uses include personal study, distribution to students, research and scholarship. Theses may only be shared by linking to the Carleton University Institutional Repository and no part may be copied without proper attribution to the author; no part may be used for commercial purposes directly or indirectly via a for-profit platform; no adaptation or derivative works are permitted without consent from the copyright owner."],"dc:subject.lcsh":["Physics"],"dc:title":["Separating the vascular and nonvascular sources of magnetic susceptibility in physiological MRI techniques based on the reversible transverse relaxation rate, R2’"],"dc:type":["thesis"],"local:lac.licence":["true"],"others:access_status":["open.access"],"thesis:degree_discipline":["Physics"],"thesis:degree_level":["Master's"],"thesis:degree_name":["Master of Science (M.Sc.)"]},"updated_at":"2026-11-19T07:02:57Z"}