{"id":{"repo_id":"carleton","oai_identifier":"oai:carleton.scholaris.ca:20.500.14718/43931"},"canonical_url":"https://search.ndltd.org/etd/carleton/oai:carleton.scholaris.ca:20.500.14718/43931","repository":{"repo_id":"carleton","name":"Carleton University","base_url":"https://carleton.scholaris.ca/server/oai/request"},"display":{"title":"Modelling of Open-Ended Coaxial Probes for Real-Time Dielectric Spectroscopy in Biomedical Applications","abstract":"Permittivity spectroscopy measures a material’s electromagnetic response across a frequency range, typically using an open-ended coaxial probe. The process involves transmitting an electromagnetic wave through the probe toward the material under test (MUT). While portion of the wave radiates into the material, the remainder reflects back due to the impedance mismatch at the probe’s aperture. Accurately determining the MUT permittivity requires precise modelling of the electromagnetic wave propagation within the probe, but current methods have notable limitations: 1) balancing accuracy and efficiency remains challenging, with one often sacrificed for the other, 2) most models assume single-layer MUTs, and 3) accurate models for needle-shaped probes, such as bevelled or conical shapes, are lacking. This thesis addresses these challenges with three main contributions. First, it introduces a closed-form, full-wave model reduced to a simple matrix multiplication. The model has been validated experimentally using two coaxial probes and four reference liquids. It exhibited an average error of 4.35%, which is similar to or better than state-of-the-art models, while being 98% faster Second, it proposes a model for calculating the permittivity of a two-layer MUT. The proposed method is validated experimentally in two different scenarios within a frequency range of 1 GHz to 5 GHz. The average error of the extracted permittivity from the inverse problem is 1.08%, and the average error in the extracted distance is 10 μm. Lastly, this thesis introduces a model for bevelled and conical probes that can penetrate tissue for in-vivo measurements. The accuracy of the model is validated using experimental measurements on water, with a relative error of less than 1%. Overall, these models represent an important step toward establishing permittivity spectroscopy as a next-generation diagnostic modality.","abstract_html":"Permittivity spectroscopy measures a material’s electromagnetic response across a frequency range, typically using an open-ended coaxial probe. The process involves transmitting an electromagnetic wave through the probe toward the material under test (MUT). While portion of the wave radiates into the material, the remainder reflects back due to the impedance mismatch at the probe’s aperture. Accurately determining the MUT permittivity requires precise modelling of the electromagnetic wave propagation within the probe, but current methods have notable limitations: 1) balancing accuracy and efficiency remains challenging, with one often sacrificed for the other, 2) most models assume single-layer MUTs, and 3) accurate models for needle-shaped probes, such as bevelled or conical shapes, are lacking. This thesis addresses these challenges with three main contributions. First, it introduces a closed-form, full-wave model reduced to a simple matrix multiplication. The model has been validated experimentally using two coaxial probes and four reference liquids. It exhibited an average error of 4.35%, which is similar to or better than state-of-the-art models, while being 98% faster Second, it proposes a model for calculating the permittivity of a two-layer MUT. The proposed method is validated experimentally in two different scenarios within a frequency range of 1 GHz to 5 GHz. The average error of the extracted permittivity from the inverse problem is 1.08%, and the average error in the extracted distance is 10 μm. Lastly, this thesis introduces a model for bevelled and conical probes that can penetrate tissue for in-vivo measurements. The accuracy of the model is validated using experimental measurements on water, with a relative error of less than 1%. Overall, these models represent an important step toward establishing permittivity spectroscopy as a next-generation diagnostic modality.","abstract_has_math":false,"creators":["Asilian Bidgoli, Hossein"],"institution":"Carleton University","degree_name":"Doctor of Philosophy (Ph.D.)","degree_level":"Doctoral","degree_discipline":"Engineering, Electrical and Computer","degree_department":null,"school":null,"contributors":[],"advisors":[],"committee_chairs":[],"committee_members":[],"year":2025,"date_issued":"2025","date_published":"2025","updated_at":"2026-11-19T07:09:12Z","subjects":["Electrical engineering","Biomedical engineering","Mathematics"],"languages":["en"],"rights":["Copyright © 2025 the author(s). Theses may be used for non-commercial research, educational, or related academic purposes only. Such uses include personal study, distribution to students, research and scholarship. Theses may only be shared by linking to the Carleton University Institutional Repository and no part may be copied without proper attribution to the author; no part may be used for commercial purposes directly or indirectly via a for-profit platform; no adaptation or derivative works are permitted without consent from the copyright owner."],"rights_urls":[],"identifier_entries":[{"key":"dc:identifier.doi","label":"DOI","values":["10.22215/etd/2025-16564"],"render_values":[{"text":"10.22215/etd/2025-16564","href":"https://doi.org/10.22215/etd/2025-16564","code":true}]}],"person_identifier_entries":[]},"links":{"outbound_url":"https://hdl.handle.net/20.500.14718/43931","outbound_label":"Handle","outbound_source":"dc:identifier.uri","record_url":"https://hdl.handle.net/20.500.14718/43931","record_label":"Repository record","record_kind":"handle","record_source":"dc:identifier.uri","download_url":null,"download_label":null,"download_source":null,"access_status":null,"embargo_until":null,"access_note":null},"source_record":{"url":"https://carleton.scholaris.ca/server/oai/request?verb=GetRecord&metadataPrefix=dim&identifier=oai%3Acarleton.scholaris.ca%3A20.500.14718%2F43931","prefix":"dim"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:creator","label":"Author","values":["Asilian Bidgoli, Hossein"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2025-07-31T18:36:48Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2025-07-31T18:36:48Z"]},{"key":"dc:date.issued","label":"Date","values":["2025"]},{"key":"dc:publisher","label":"Institution","values":["Carleton University"]},{"key":"dc:type","label":"Dc Type","values":["thesis"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Engineering, Electrical and Computer"]},{"key":"thesis:degree_level","label":"Degree Level","values":["Doctoral"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Doctor of Philosophy (Ph.D.)"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject.lcsh","label":"Dc Subject Lcsh","values":["Electrical engineering","Biomedical engineering","Mathematics"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language.iso","label":"Language (ISO)","values":["en"]},{"key":"dc:rights","label":"Dc Rights","values":["Copyright © 2025 the author(s). Theses may be used for non-commercial research, educational, or related academic purposes only. Such uses include personal study, distribution to students, research and scholarship. Theses may only be shared by linking to the Carleton University Institutional Repository and no part may be copied without proper attribution to the author; no part may be used for commercial purposes directly or indirectly via a for-profit platform; no adaptation or derivative works are permitted without consent from the copyright owner."]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.doi","label":"DOI","values":["10.22215/etd/2025-16564"]},{"key":"dc:identifier.uri","label":"Identifier URI","values":["https://hdl.handle.net/20.500.14718/43931"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["Permittivity spectroscopy measures a material’s electromagnetic response across a frequency range, typically using an open-ended coaxial probe. The process involves transmitting an electromagnetic wave through the probe toward the material under test (MUT). While portion of the wave radiates into the material, the remainder reflects back due to the impedance mismatch at the probe’s aperture. Accurately determining the MUT permittivity requires precise modelling of the electromagnetic wave propagation within the probe, but current methods have notable limitations: 1) balancing accuracy and efficiency remains challenging, with one often sacrificed for the other, 2) most models assume single-layer MUTs, and 3) accurate models for needle-shaped probes, such as bevelled or conical shapes, are lacking. This thesis addresses these challenges with three main contributions. First, it introduces a closed-form, full-wave model reduced to a simple matrix multiplication. The model has been validated experimentally using two coaxial probes and four reference liquids. It exhibited an average error of 4.35%, which is similar to or better than state-of-the-art models, while being 98% faster Second, it proposes a model for calculating the permittivity of a two-layer MUT. The proposed method is validated experimentally in two different scenarios within a frequency range of 1 GHz to 5 GHz. The average error of the extracted permittivity from the inverse problem is 1.08%, and the average error in the extracted distance is 10 μm. Lastly, this thesis introduces a model for bevelled and conical probes that can penetrate tissue for in-vivo measurements. The accuracy of the model is validated using experimental measurements on water, with a relative error of less than 1%. Overall, these models represent an important step toward establishing permittivity spectroscopy as a next-generation diagnostic modality."]},{"key":"dc:title","label":"Title","values":["Modelling of Open-Ended Coaxial Probes for Real-Time Dielectric Spectroscopy in Biomedical Applications"]},{"key":"local:lac.licence","label":"Local Lac Licence","values":["true"]},{"key":"others:access_status","label":"Others Access Status","values":["open.access"]}]}],"canonical_facts":{"dc:creator":["Asilian Bidgoli, Hossein"],"dc:date.accessioned":["2025-07-31T18:36:48Z"],"dc:date.available":["2025-07-31T18:36:48Z"],"dc:date.issued":["2025"],"dc:description.abstract":["Permittivity spectroscopy measures a material’s electromagnetic response across a frequency range, typically using an open-ended coaxial probe. The process involves transmitting an electromagnetic wave through the probe toward the material under test (MUT). While portion of the wave radiates into the material, the remainder reflects back due to the impedance mismatch at the probe’s aperture. Accurately determining the MUT permittivity requires precise modelling of the electromagnetic wave propagation within the probe, but current methods have notable limitations: 1) balancing accuracy and efficiency remains challenging, with one often sacrificed for the other, 2) most models assume single-layer MUTs, and 3) accurate models for needle-shaped probes, such as bevelled or conical shapes, are lacking. This thesis addresses these challenges with three main contributions. First, it introduces a closed-form, full-wave model reduced to a simple matrix multiplication. The model has been validated experimentally using two coaxial probes and four reference liquids. It exhibited an average error of 4.35%, which is similar to or better than state-of-the-art models, while being 98% faster Second, it proposes a model for calculating the permittivity of a two-layer MUT. The proposed method is validated experimentally in two different scenarios within a frequency range of 1 GHz to 5 GHz. The average error of the extracted permittivity from the inverse problem is 1.08%, and the average error in the extracted distance is 10 μm. Lastly, this thesis introduces a model for bevelled and conical probes that can penetrate tissue for in-vivo measurements. The accuracy of the model is validated using experimental measurements on water, with a relative error of less than 1%. Overall, these models represent an important step toward establishing permittivity spectroscopy as a next-generation diagnostic modality."],"dc:identifier.doi":["10.22215/etd/2025-16564"],"dc:identifier.uri":["https://hdl.handle.net/20.500.14718/43931"],"dc:language.iso":["en"],"dc:publisher":["Carleton University"],"dc:rights":["Copyright © 2025 the author(s). Theses may be used for non-commercial research, educational, or related academic purposes only. Such uses include personal study, distribution to students, research and scholarship. Theses may only be shared by linking to the Carleton University Institutional Repository and no part may be copied without proper attribution to the author; no part may be used for commercial purposes directly or indirectly via a for-profit platform; no adaptation or derivative works are permitted without consent from the copyright owner."],"dc:subject.lcsh":["Electrical engineering","Biomedical engineering","Mathematics"],"dc:title":["Modelling of Open-Ended Coaxial Probes for Real-Time Dielectric Spectroscopy in Biomedical Applications"],"dc:type":["thesis"],"local:lac.licence":["true"],"others:access_status":["open.access"],"thesis:degree_discipline":["Engineering, Electrical and Computer"],"thesis:degree_level":["Doctoral"],"thesis:degree_name":["Doctor of Philosophy (Ph.D.)"]},"updated_at":"2026-11-19T07:09:12Z"}