{"id":{"repo_id":"carleton","oai_identifier":"oai:carleton.scholaris.ca:20.500.14718/43956"},"canonical_url":"https://search.ndltd.org/etd/carleton/oai:carleton.scholaris.ca:20.500.14718/43956","repository":{"repo_id":"carleton","name":"Carleton University","base_url":"https://carleton.scholaris.ca/server/oai/request"},"display":{"title":"Speed Control of Permanent Magnet Synchronous Motor Employing Direct Voltage Maximum Torque Per Ampere","abstract":"Permanent magnet synchronous motors (PMSMs) have become more attractive and competitive for various industrial applications. In the constant torque region, a commonly adopted technique for maximum torque utilization of PMSMs is known as maximum torque per ampere control (MTPA). This technique aims to achieve the desired torque with minimal current consumption. Conventional MTPA control approaches typically utilize PI-based cascaded control loops, which lead to significant time costs in practical. In contrast, direct voltage control methods (DVC) are alternative techniques to track the MTPA points by directly manipulating the voltage vector amplitude and angle, eliminating the need for cascaded regulation. However, the few developed direct voltage control methods still rely on complex torque estimation, numerical approximations of a given motor, lookup tables, and lengthy iterative calculations to determine its control laws. In view of these limitations, this thesis aims to introduce various analytical simplified direct voltage maximum torque per ampere speed control approaches. Initially, a simple current sensing-based direct voltage MTPA control is introduced for IPMSM propelling electric vehicles. The design strategy’s voltage amplitude and angle control laws are analytically derived from the motor’s electrical model based on measured stator current, eliminating the need for torque estimation, control law approximation, or iterative solution. Direct Voltage MTPA techniques are model-based approaches that depend heavily on time-varying electrical parameters. Furthermore, shaft speed and position are of great importance in these strategies. To overcome the adverse effects of parameter variation and mechanical sensor drawbacks, a multiparameter estimation-based sensorless adaptive direct voltage MTPA control is introduced for IPMSM. A fuzzy logic control-based cascaded model reference adaptive system (FLC-MRAS) is suggested for online parameter tracking and provides precise rotor speed and position. To further reduce the control system’s complexity and improve its reliability, a simple current sensorless MTPA control is proposed to control the speed of the IPMSM and SPMSM. The proposed strategy eliminates the need for current sensing, transformations, and regulation loops. The validity of the designed strategies is confirmed experimentally, and the results obtained are compared to the conventional field-oriented MTPA (FOC). Additionally, the performance of the developed strategies is quantitatively assessed.","abstract_html":"Permanent magnet synchronous motors (PMSMs) have become more attractive and competitive for various industrial applications. In the constant torque region, a commonly adopted technique for maximum torque utilization of PMSMs is known as maximum torque per ampere control (MTPA). This technique aims to achieve the desired torque with minimal current consumption. Conventional MTPA control approaches typically utilize PI-based cascaded control loops, which lead to significant time costs in practical. In contrast, direct voltage control methods (DVC) are alternative techniques to track the MTPA points by directly manipulating the voltage vector amplitude and angle, eliminating the need for cascaded regulation. However, the few developed direct voltage control methods still rely on complex torque estimation, numerical approximations of a given motor, lookup tables, and lengthy iterative calculations to determine its control laws. In view of these limitations, this thesis aims to introduce various analytical simplified direct voltage maximum torque per ampere speed control approaches. Initially, a simple current sensing-based direct voltage MTPA control is introduced for IPMSM propelling electric vehicles. The design strategy’s voltage amplitude and angle control laws are analytically derived from the motor’s electrical model based on measured stator current, eliminating the need for torque estimation, control law approximation, or iterative solution. Direct Voltage MTPA techniques are model-based approaches that depend heavily on time-varying electrical parameters. Furthermore, shaft speed and position are of great importance in these strategies. To overcome the adverse effects of parameter variation and mechanical sensor drawbacks, a multiparameter estimation-based sensorless adaptive direct voltage MTPA control is introduced for IPMSM. A fuzzy logic control-based cascaded model reference adaptive system (FLC-MRAS) is suggested for online parameter tracking and provides precise rotor speed and position. To further reduce the control system’s complexity and improve its reliability, a simple current sensorless MTPA control is proposed to control the speed of the IPMSM and SPMSM. The proposed strategy eliminates the need for current sensing, transformations, and regulation loops. The validity of the designed strategies is confirmed experimentally, and the results obtained are compared to the conventional field-oriented MTPA (FOC). Additionally, the performance of the developed strategies is quantitatively assessed.","abstract_has_math":false,"creators":["Elhaj, Alaref Elm M"],"institution":"Carleton University","degree_name":"Doctor of Philosophy (Ph.D.)","degree_level":"Doctoral","degree_discipline":"Engineering, Electrical and Computer","degree_department":null,"school":null,"contributors":[],"advisors":[],"committee_chairs":[],"committee_members":[],"year":2025,"date_issued":"2025","date_published":"2025","updated_at":"2026-11-19T06:57:16Z","subjects":["Electrical engineering","Automobiles","Industrial engineering"],"languages":["en"],"rights":["Copyright © 2025 the author(s). Theses may be used for non-commercial research, educational, or related academic purposes only. Such uses include personal study, distribution to students, research and scholarship. Theses may only be shared by linking to the Carleton University Institutional Repository and no part may be copied without proper attribution to the author; no part may be used for commercial purposes directly or indirectly via a for-profit platform; no adaptation or derivative works are permitted without consent from the copyright owner."],"rights_urls":[],"identifier_entries":[{"key":"dc:identifier.uri","label":"Identifier URI","values":["https://hdl.handle.net/20.500.14718/43956"],"render_values":[{"text":"https://hdl.handle.net/20.500.14718/43956","href":"https://hdl.handle.net/20.500.14718/43956","code":true}]}],"person_identifier_entries":[]},"links":{"outbound_url":"https://doi.org/10.22215/etd/2025-16589","outbound_label":"DOI","outbound_source":"dc:identifier.doi","record_url":"https://doi.org/10.22215/etd/2025-16589","record_label":"Repository record","record_kind":"doi","record_source":"dc:identifier.doi","access_status":null,"embargo_until":null,"access_note":null},"source_record":{"url":"https://carleton.scholaris.ca/server/oai/request?verb=GetRecord&metadataPrefix=dim&identifier=oai%3Acarleton.scholaris.ca%3A20.500.14718%2F43956","prefix":"dim"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:creator","label":"Author","values":["Elhaj, Alaref Elm M"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2025-07-31T18:37:32Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2025-07-31T18:37:32Z"]},{"key":"dc:date.issued","label":"Date","values":["2025"]},{"key":"dc:publisher","label":"Institution","values":["Carleton University"]},{"key":"dc:type","label":"Dc Type","values":["thesis"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Engineering, Electrical and Computer"]},{"key":"thesis:degree_level","label":"Degree Level","values":["Doctoral"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Doctor of Philosophy (Ph.D.)"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject.lcsh","label":"Dc Subject Lcsh","values":["Electrical engineering","Automobiles","Industrial engineering"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language.iso","label":"Language (ISO)","values":["en"]},{"key":"dc:rights","label":"Dc Rights","values":["Copyright © 2025 the author(s). Theses may be used for non-commercial research, educational, or related academic purposes only. Such uses include personal study, distribution to students, research and scholarship. Theses may only be shared by linking to the Carleton University Institutional Repository and no part may be copied without proper attribution to the author; no part may be used for commercial purposes directly or indirectly via a for-profit platform; no adaptation or derivative works are permitted without consent from the copyright owner."]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.doi","label":"DOI","values":["10.22215/etd/2025-16589"]},{"key":"dc:identifier.uri","label":"Identifier URI","values":["https://hdl.handle.net/20.500.14718/43956"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["Permanent magnet synchronous motors (PMSMs) have become more attractive and competitive for various industrial applications. In the constant torque region, a commonly adopted technique for maximum torque utilization of PMSMs is known as maximum torque per ampere control (MTPA). This technique aims to achieve the desired torque with minimal current consumption. Conventional MTPA control approaches typically utilize PI-based cascaded control loops, which lead to significant time costs in practical. In contrast, direct voltage control methods (DVC) are alternative techniques to track the MTPA points by directly manipulating the voltage vector amplitude and angle, eliminating the need for cascaded regulation. However, the few developed direct voltage control methods still rely on complex torque estimation, numerical approximations of a given motor, lookup tables, and lengthy iterative calculations to determine its control laws. In view of these limitations, this thesis aims to introduce various analytical simplified direct voltage maximum torque per ampere speed control approaches. Initially, a simple current sensing-based direct voltage MTPA control is introduced for IPMSM propelling electric vehicles. The design strategy’s voltage amplitude and angle control laws are analytically derived from the motor’s electrical model based on measured stator current, eliminating the need for torque estimation, control law approximation, or iterative solution. Direct Voltage MTPA techniques are model-based approaches that depend heavily on time-varying electrical parameters. Furthermore, shaft speed and position are of great importance in these strategies. To overcome the adverse effects of parameter variation and mechanical sensor drawbacks, a multiparameter estimation-based sensorless adaptive direct voltage MTPA control is introduced for IPMSM. A fuzzy logic control-based cascaded model reference adaptive system (FLC-MRAS) is suggested for online parameter tracking and provides precise rotor speed and position. To further reduce the control system’s complexity and improve its reliability, a simple current sensorless MTPA control is proposed to control the speed of the IPMSM and SPMSM. The proposed strategy eliminates the need for current sensing, transformations, and regulation loops. The validity of the designed strategies is confirmed experimentally, and the results obtained are compared to the conventional field-oriented MTPA (FOC). Additionally, the performance of the developed strategies is quantitatively assessed."]},{"key":"dc:title","label":"Title","values":["Speed Control of Permanent Magnet Synchronous Motor Employing Direct Voltage Maximum Torque Per Ampere"]},{"key":"local:lac.licence","label":"Local Lac Licence","values":["true"]},{"key":"others:access_status","label":"Others Access Status","values":["open.access"]}]}],"canonical_facts":{"dc:creator":["Elhaj, Alaref Elm M"],"dc:date.accessioned":["2025-07-31T18:37:32Z"],"dc:date.available":["2025-07-31T18:37:32Z"],"dc:date.issued":["2025"],"dc:description.abstract":["Permanent magnet synchronous motors (PMSMs) have become more attractive and competitive for various industrial applications. In the constant torque region, a commonly adopted technique for maximum torque utilization of PMSMs is known as maximum torque per ampere control (MTPA). This technique aims to achieve the desired torque with minimal current consumption. Conventional MTPA control approaches typically utilize PI-based cascaded control loops, which lead to significant time costs in practical. In contrast, direct voltage control methods (DVC) are alternative techniques to track the MTPA points by directly manipulating the voltage vector amplitude and angle, eliminating the need for cascaded regulation. However, the few developed direct voltage control methods still rely on complex torque estimation, numerical approximations of a given motor, lookup tables, and lengthy iterative calculations to determine its control laws. In view of these limitations, this thesis aims to introduce various analytical simplified direct voltage maximum torque per ampere speed control approaches. Initially, a simple current sensing-based direct voltage MTPA control is introduced for IPMSM propelling electric vehicles. The design strategy’s voltage amplitude and angle control laws are analytically derived from the motor’s electrical model based on measured stator current, eliminating the need for torque estimation, control law approximation, or iterative solution. Direct Voltage MTPA techniques are model-based approaches that depend heavily on time-varying electrical parameters. Furthermore, shaft speed and position are of great importance in these strategies. To overcome the adverse effects of parameter variation and mechanical sensor drawbacks, a multiparameter estimation-based sensorless adaptive direct voltage MTPA control is introduced for IPMSM. A fuzzy logic control-based cascaded model reference adaptive system (FLC-MRAS) is suggested for online parameter tracking and provides precise rotor speed and position. To further reduce the control system’s complexity and improve its reliability, a simple current sensorless MTPA control is proposed to control the speed of the IPMSM and SPMSM. The proposed strategy eliminates the need for current sensing, transformations, and regulation loops. The validity of the designed strategies is confirmed experimentally, and the results obtained are compared to the conventional field-oriented MTPA (FOC). Additionally, the performance of the developed strategies is quantitatively assessed."],"dc:identifier.doi":["10.22215/etd/2025-16589"],"dc:identifier.uri":["https://hdl.handle.net/20.500.14718/43956"],"dc:language.iso":["en"],"dc:publisher":["Carleton University"],"dc:rights":["Copyright © 2025 the author(s). Theses may be used for non-commercial research, educational, or related academic purposes only. Such uses include personal study, distribution to students, research and scholarship. Theses may only be shared by linking to the Carleton University Institutional Repository and no part may be copied without proper attribution to the author; no part may be used for commercial purposes directly or indirectly via a for-profit platform; no adaptation or derivative works are permitted without consent from the copyright owner."],"dc:subject.lcsh":["Electrical engineering","Automobiles","Industrial engineering"],"dc:title":["Speed Control of Permanent Magnet Synchronous Motor Employing Direct Voltage Maximum Torque Per Ampere"],"dc:type":["thesis"],"local:lac.licence":["true"],"others:access_status":["open.access"],"thesis:degree_discipline":["Engineering, Electrical and Computer"],"thesis:degree_level":["Doctoral"],"thesis:degree_name":["Doctor of Philosophy (Ph.D.)"]},"updated_at":"2026-11-19T06:57:16Z"}