{"id":{"repo_id":"carleton","oai_identifier":"oai:carleton.scholaris.ca:20.500.14718/43958"},"canonical_url":"https://search.ndltd.org/etd/carleton/oai:carleton.scholaris.ca:20.500.14718/43958","repository":{"repo_id":"carleton","name":"Carleton University","base_url":"https://carleton.scholaris.ca/server/oai/request"},"display":{"title":"Optimization of Building Integrated Phase Change Materials Using Experiments and Simulation","abstract":"LHTES systems use PCMs to absorb and release thermal energy during solid-liquid transitions. When applied in buildings, PCMs enhance thermal inertia, reduce peak conditioning loads, and improve occupant comfort. This thesis aimed to optimize passive LHTES systems based on solar insolation profiles. An insolation analysis tool was developed, leading to the identification of the northern and southern portions of an in-situ chamber’s floor as areas of highest insolation exposure during heating and cooling seasons respectively. ESP-r modeling assessed the impact of various parameters on temperature profiles. To prevent overheating, a reduced window size and controlled ventilation system were added. Experimental testing compared the thermal performance of optimized PCM cement tiles, uniformly distributed PCM tiles, and pure cement tiles. Results between the optimized and uniform PCM tiles showed a 13.5% increase in cooling loads and a 3.6% decrease in heating loads, indicating optimization potential in cold climates.","abstract_html":"LHTES systems use PCMs to absorb and release thermal energy during solid-liquid transitions. When applied in buildings, PCMs enhance thermal inertia, reduce peak conditioning loads, and improve occupant comfort. This thesis aimed to optimize passive LHTES systems based on solar insolation profiles. An insolation analysis tool was developed, leading to the identification of the northern and southern portions of an in-situ chamber’s floor as areas of highest insolation exposure during heating and cooling seasons respectively. ESP-r modeling assessed the impact of various parameters on temperature profiles. To prevent overheating, a reduced window size and controlled ventilation system were added. Experimental testing compared the thermal performance of optimized PCM cement tiles, uniformly distributed PCM tiles, and pure cement tiles. Results between the optimized and uniform PCM tiles showed a 13.5% increase in cooling loads and a 3.6% decrease in heating loads, indicating optimization potential in cold climates.","abstract_has_math":false,"creators":["Hay, Nathan Robert"],"institution":"Carleton University","degree_name":"Master of Applied Science (M.App.Sc.)","degree_level":"Master's","degree_discipline":"Engineering, Mechanical","degree_department":null,"school":null,"contributors":[],"advisors":[],"committee_chairs":[],"committee_members":[],"year":2025,"date_issued":"2025","date_published":"2025","updated_at":"2026-11-19T07:14:27Z","subjects":["Mechanics, Applied"],"languages":["en"],"rights":["Copyright © 2025 the author(s). Theses may be used for non-commercial research, educational, or related academic purposes only. Such uses include personal study, distribution to students, research and scholarship. Theses may only be shared by linking to the Carleton University Institutional Repository and no part may be copied without proper attribution to the author; no part may be used for commercial purposes directly or indirectly via a for-profit platform; no adaptation or derivative works are permitted without consent from the copyright owner."],"rights_urls":[],"identifier_entries":[{"key":"dc:identifier.doi","label":"DOI","values":["10.22215/etd/2025-16591"],"render_values":[{"text":"10.22215/etd/2025-16591","href":"https://doi.org/10.22215/etd/2025-16591","code":true}]}],"person_identifier_entries":[]},"links":{"outbound_url":"https://hdl.handle.net/20.500.14718/43958","outbound_label":"Handle","outbound_source":"dc:identifier.uri","record_url":"https://hdl.handle.net/20.500.14718/43958","record_label":"Repository record","record_kind":"handle","record_source":"dc:identifier.uri","download_url":null,"download_label":null,"download_source":null,"access_status":null,"embargo_until":null,"access_note":null},"source_record":{"url":"https://carleton.scholaris.ca/server/oai/request?verb=GetRecord&metadataPrefix=dim&identifier=oai%3Acarleton.scholaris.ca%3A20.500.14718%2F43958","prefix":"dim"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:creator","label":"Author","values":["Hay, Nathan Robert"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2025-07-31T18:37:37Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2025-07-31T18:37:37Z"]},{"key":"dc:date.issued","label":"Date","values":["2025"]},{"key":"dc:publisher","label":"Institution","values":["Carleton University"]},{"key":"dc:type","label":"Dc Type","values":["thesis"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Engineering, Mechanical"]},{"key":"thesis:degree_level","label":"Degree Level","values":["Master's"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Master of Applied Science (M.App.Sc.)"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject.lcsh","label":"Dc Subject Lcsh","values":["Mechanics, Applied"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language.iso","label":"Language (ISO)","values":["en"]},{"key":"dc:rights","label":"Dc Rights","values":["Copyright © 2025 the author(s). Theses may be used for non-commercial research, educational, or related academic purposes only. Such uses include personal study, distribution to students, research and scholarship. Theses may only be shared by linking to the Carleton University Institutional Repository and no part may be copied without proper attribution to the author; no part may be used for commercial purposes directly or indirectly via a for-profit platform; no adaptation or derivative works are permitted without consent from the copyright owner."]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.doi","label":"DOI","values":["10.22215/etd/2025-16591"]},{"key":"dc:identifier.uri","label":"Identifier URI","values":["https://hdl.handle.net/20.500.14718/43958"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["LHTES systems use PCMs to absorb and release thermal energy during solid-liquid transitions. When applied in buildings, PCMs enhance thermal inertia, reduce peak conditioning loads, and improve occupant comfort. This thesis aimed to optimize passive LHTES systems based on solar insolation profiles. An insolation analysis tool was developed, leading to the identification of the northern and southern portions of an in-situ chamber’s floor as areas of highest insolation exposure during heating and cooling seasons respectively. ESP-r modeling assessed the impact of various parameters on temperature profiles. To prevent overheating, a reduced window size and controlled ventilation system were added. Experimental testing compared the thermal performance of optimized PCM cement tiles, uniformly distributed PCM tiles, and pure cement tiles. Results between the optimized and uniform PCM tiles showed a 13.5% increase in cooling loads and a 3.6% decrease in heating loads, indicating optimization potential in cold climates."]},{"key":"dc:title","label":"Title","values":["Optimization of Building Integrated Phase Change Materials Using Experiments and Simulation"]},{"key":"local:lac.licence","label":"Local Lac Licence","values":["true"]},{"key":"others:access_status","label":"Others Access Status","values":["open.access"]}]}],"canonical_facts":{"dc:creator":["Hay, Nathan Robert"],"dc:date.accessioned":["2025-07-31T18:37:37Z"],"dc:date.available":["2025-07-31T18:37:37Z"],"dc:date.issued":["2025"],"dc:description.abstract":["LHTES systems use PCMs to absorb and release thermal energy during solid-liquid transitions. When applied in buildings, PCMs enhance thermal inertia, reduce peak conditioning loads, and improve occupant comfort. This thesis aimed to optimize passive LHTES systems based on solar insolation profiles. An insolation analysis tool was developed, leading to the identification of the northern and southern portions of an in-situ chamber’s floor as areas of highest insolation exposure during heating and cooling seasons respectively. ESP-r modeling assessed the impact of various parameters on temperature profiles. To prevent overheating, a reduced window size and controlled ventilation system were added. Experimental testing compared the thermal performance of optimized PCM cement tiles, uniformly distributed PCM tiles, and pure cement tiles. Results between the optimized and uniform PCM tiles showed a 13.5% increase in cooling loads and a 3.6% decrease in heating loads, indicating optimization potential in cold climates."],"dc:identifier.doi":["10.22215/etd/2025-16591"],"dc:identifier.uri":["https://hdl.handle.net/20.500.14718/43958"],"dc:language.iso":["en"],"dc:publisher":["Carleton University"],"dc:rights":["Copyright © 2025 the author(s). Theses may be used for non-commercial research, educational, or related academic purposes only. Such uses include personal study, distribution to students, research and scholarship. Theses may only be shared by linking to the Carleton University Institutional Repository and no part may be copied without proper attribution to the author; no part may be used for commercial purposes directly or indirectly via a for-profit platform; no adaptation or derivative works are permitted without consent from the copyright owner."],"dc:subject.lcsh":["Mechanics, Applied"],"dc:title":["Optimization of Building Integrated Phase Change Materials Using Experiments and Simulation"],"dc:type":["thesis"],"local:lac.licence":["true"],"others:access_status":["open.access"],"thesis:degree_discipline":["Engineering, Mechanical"],"thesis:degree_level":["Master's"],"thesis:degree_name":["Master of Applied Science (M.App.Sc.)"]},"updated_at":"2026-11-19T07:14:27Z"}