{"id":{"repo_id":"carleton","oai_identifier":"oai:carleton.scholaris.ca:20.500.14718/43971"},"canonical_url":"https://search.ndltd.org/etd/carleton/oai:carleton.scholaris.ca:20.500.14718/43971","repository":{"repo_id":"carleton","name":"Carleton University","base_url":"https://carleton.scholaris.ca/server/oai/request"},"display":{"title":"Effect of Redundancy on Seismic Performance of Braced Frame Buildings in Eastern and Western Canada","abstract":"Structural redundancy plays a critical role in the seismic performance of buildings. However, in Canada, it is not explicitly addressed in design codes, and other standards, such as ASCE 7-22, apply uniform redundancy factors without accounting for system-specific variations. This study investigates redundancy effects in chevron braced steel frame buildings using nine five-storey archetypes with varying bracing layouts and configurations, designed for Montreal and Vancouver. Archetypes were analyzed in OpenSees using pushover and incremental dynamic analyses (IDA). Pushover results showed that redundancy, particularly through additional braced bays, improved overstrength. IDA results revealed similar trends at the Life Safety and Collapse Prevention levels, while Immediate Occupancy was more influenced by brace quantity than layout. Regression analyses confirmed strong correlations between performance metrics and structural parameters. This work presents a performance-based framework for redundancy assessment to support refinement of seismic design standards and evaluation procedures in Canada and the United States.","abstract_html":"Structural redundancy plays a critical role in the seismic performance of buildings. However, in Canada, it is not explicitly addressed in design codes, and other standards, such as ASCE 7-22, apply uniform redundancy factors without accounting for system-specific variations. This study investigates redundancy effects in chevron braced steel frame buildings using nine five-storey archetypes with varying bracing layouts and configurations, designed for Montreal and Vancouver. Archetypes were analyzed in OpenSees using pushover and incremental dynamic analyses (IDA). Pushover results showed that redundancy, particularly through additional braced bays, improved overstrength. IDA results revealed similar trends at the Life Safety and Collapse Prevention levels, while Immediate Occupancy was more influenced by brace quantity than layout. Regression analyses confirmed strong correlations between performance metrics and structural parameters. This work presents a performance-based framework for redundancy assessment to support refinement of seismic design standards and evaluation procedures in Canada and the United States.","abstract_has_math":false,"creators":["Toopchinezhad, Mostafa"],"institution":"Carleton University","degree_name":"Master of Applied Science (M.App.Sc.)","degree_level":"Master's","degree_discipline":"Engineering, Civil","degree_department":null,"school":null,"contributors":[],"advisors":[],"committee_chairs":[],"committee_members":[],"year":2025,"date_issued":"2025","date_published":"2025","updated_at":"2026-11-19T06:58:20Z","subjects":["Civil engineering"],"languages":["en"],"rights":["Copyright © 2025 the author(s). Theses may be used for non-commercial research, educational, or related academic purposes only. Such uses include personal study, distribution to students, research and scholarship. Theses may only be shared by linking to the Carleton University Institutional Repository and no part may be copied without proper attribution to the author; no part may be used for commercial purposes directly or indirectly via a for-profit platform; no adaptation or derivative works are permitted without consent from the copyright owner."],"rights_urls":[],"identifier_entries":[{"key":"dc:identifier.doi","label":"DOI","values":["10.22215/etd/2025-16604"],"render_values":[{"text":"10.22215/etd/2025-16604","href":"https://doi.org/10.22215/etd/2025-16604","code":true}]}],"person_identifier_entries":[]},"links":{"outbound_url":"https://hdl.handle.net/20.500.14718/43971","outbound_label":"Handle","outbound_source":"dc:identifier.uri","record_url":"https://hdl.handle.net/20.500.14718/43971","record_label":"Repository record","record_kind":"handle","record_source":"dc:identifier.uri","download_url":null,"download_label":null,"download_source":null,"access_status":null,"embargo_until":null,"access_note":null},"source_record":{"url":"https://carleton.scholaris.ca/server/oai/request?verb=GetRecord&metadataPrefix=dim&identifier=oai%3Acarleton.scholaris.ca%3A20.500.14718%2F43971","prefix":"dim"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:creator","label":"Author","values":["Toopchinezhad, Mostafa"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2025-07-31T18:37:55Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2025-07-31T18:37:55Z"]},{"key":"dc:date.issued","label":"Date","values":["2025"]},{"key":"dc:publisher","label":"Institution","values":["Carleton University"]},{"key":"dc:type","label":"Dc Type","values":["thesis"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Engineering, Civil"]},{"key":"thesis:degree_level","label":"Degree Level","values":["Master's"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Master of Applied Science (M.App.Sc.)"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject.lcsh","label":"Dc Subject Lcsh","values":["Civil engineering"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language.iso","label":"Language (ISO)","values":["en"]},{"key":"dc:rights","label":"Dc Rights","values":["Copyright © 2025 the author(s). Theses may be used for non-commercial research, educational, or related academic purposes only. Such uses include personal study, distribution to students, research and scholarship. Theses may only be shared by linking to the Carleton University Institutional Repository and no part may be copied without proper attribution to the author; no part may be used for commercial purposes directly or indirectly via a for-profit platform; no adaptation or derivative works are permitted without consent from the copyright owner."]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.doi","label":"DOI","values":["10.22215/etd/2025-16604"]},{"key":"dc:identifier.uri","label":"Identifier URI","values":["https://hdl.handle.net/20.500.14718/43971"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["Structural redundancy plays a critical role in the seismic performance of buildings. However, in Canada, it is not explicitly addressed in design codes, and other standards, such as ASCE 7-22, apply uniform redundancy factors without accounting for system-specific variations. This study investigates redundancy effects in chevron braced steel frame buildings using nine five-storey archetypes with varying bracing layouts and configurations, designed for Montreal and Vancouver. Archetypes were analyzed in OpenSees using pushover and incremental dynamic analyses (IDA). Pushover results showed that redundancy, particularly through additional braced bays, improved overstrength. IDA results revealed similar trends at the Life Safety and Collapse Prevention levels, while Immediate Occupancy was more influenced by brace quantity than layout. Regression analyses confirmed strong correlations between performance metrics and structural parameters. This work presents a performance-based framework for redundancy assessment to support refinement of seismic design standards and evaluation procedures in Canada and the United States."]},{"key":"dc:title","label":"Title","values":["Effect of Redundancy on Seismic Performance of Braced Frame Buildings in Eastern and Western Canada"]},{"key":"local:lac.licence","label":"Local Lac Licence","values":["true"]},{"key":"others:access_status","label":"Others Access Status","values":["open.access"]}]}],"canonical_facts":{"dc:creator":["Toopchinezhad, Mostafa"],"dc:date.accessioned":["2025-07-31T18:37:55Z"],"dc:date.available":["2025-07-31T18:37:55Z"],"dc:date.issued":["2025"],"dc:description.abstract":["Structural redundancy plays a critical role in the seismic performance of buildings. However, in Canada, it is not explicitly addressed in design codes, and other standards, such as ASCE 7-22, apply uniform redundancy factors without accounting for system-specific variations. This study investigates redundancy effects in chevron braced steel frame buildings using nine five-storey archetypes with varying bracing layouts and configurations, designed for Montreal and Vancouver. Archetypes were analyzed in OpenSees using pushover and incremental dynamic analyses (IDA). Pushover results showed that redundancy, particularly through additional braced bays, improved overstrength. IDA results revealed similar trends at the Life Safety and Collapse Prevention levels, while Immediate Occupancy was more influenced by brace quantity than layout. Regression analyses confirmed strong correlations between performance metrics and structural parameters. This work presents a performance-based framework for redundancy assessment to support refinement of seismic design standards and evaluation procedures in Canada and the United States."],"dc:identifier.doi":["10.22215/etd/2025-16604"],"dc:identifier.uri":["https://hdl.handle.net/20.500.14718/43971"],"dc:language.iso":["en"],"dc:publisher":["Carleton University"],"dc:rights":["Copyright © 2025 the author(s). Theses may be used for non-commercial research, educational, or related academic purposes only. Such uses include personal study, distribution to students, research and scholarship. Theses may only be shared by linking to the Carleton University Institutional Repository and no part may be copied without proper attribution to the author; no part may be used for commercial purposes directly or indirectly via a for-profit platform; no adaptation or derivative works are permitted without consent from the copyright owner."],"dc:subject.lcsh":["Civil engineering"],"dc:title":["Effect of Redundancy on Seismic Performance of Braced Frame Buildings in Eastern and Western Canada"],"dc:type":["thesis"],"local:lac.licence":["true"],"others:access_status":["open.access"],"thesis:degree_discipline":["Engineering, Civil"],"thesis:degree_level":["Master's"],"thesis:degree_name":["Master of Applied Science (M.App.Sc.)"]},"updated_at":"2026-11-19T06:58:20Z"}