{"id":{"repo_id":"carleton","oai_identifier":"oai:carleton.scholaris.ca:20.500.14718/44036"},"canonical_url":"https://search.ndltd.org/etd/carleton/oai:carleton.scholaris.ca:20.500.14718/44036","repository":{"repo_id":"carleton","name":"Carleton University","base_url":"https://carleton.scholaris.ca/server/oai/request"},"display":{"title":"Full-Scale Drinking Water Filter Assessments: Mapping Traditional and Novel Methods to Biofilter Health","abstract":"Biofiltration is a sustainable and effective method in drinking water treatment, yet operational parameters are often adopted from conventional filtration without validation. This two-year study at the Britannia and Lemieux Island Water Purification Plants evaluates biofiltration performance and backwashing strategies under full-scale conditions. Key metrics include floc retention turbidity, unit filter run volume (UFRV), dissolved organic carbon (DOC) removal, and the effects of backwash methods. Seasonal changes, particularly colder temperatures, increased solids accumulation, indicating a need for adaptive backwashing. Reduced air scour durations maintained floc retention while improving efficiency. Findings suggest conventional turbidity thresholds (<60 NTU) may be too conservative; increasing to 120 NTU or using site-specific limits may be more appropriate. While air scouring removed more floc, hydraulic backwashing maintained better DOC removal. These results demonstrate the unique behaviour of biofilters, advocating for revised operational guidelines and tailored monitoring to optimize performance and ensure effective treatment outcomes.","abstract_html":"Biofiltration is a sustainable and effective method in drinking water treatment, yet operational parameters are often adopted from conventional filtration without validation. This two-year study at the Britannia and Lemieux Island Water Purification Plants evaluates biofiltration performance and backwashing strategies under full-scale conditions. Key metrics include floc retention turbidity, unit filter run volume (UFRV), dissolved organic carbon (DOC) removal, and the effects of backwash methods. Seasonal changes, particularly colder temperatures, increased solids accumulation, indicating a need for adaptive backwashing. Reduced air scour durations maintained floc retention while improving efficiency. Findings suggest conventional turbidity thresholds (&lt;60 NTU) may be too conservative; increasing to 120 NTU or using site-specific limits may be more appropriate. While air scouring removed more floc, hydraulic backwashing maintained better DOC removal. These results demonstrate the unique behaviour of biofilters, advocating for revised operational guidelines and tailored monitoring to optimize performance and ensure effective treatment outcomes.","abstract_has_math":false,"creators":["Jeaurond, Zoé"],"institution":"Carleton University","degree_name":"Master of Applied Science (M.App.Sc.)","degree_level":"Master's","degree_discipline":"Engineering, Environmental","degree_department":null,"school":null,"contributors":[],"advisors":[],"committee_chairs":[],"committee_members":[],"year":2025,"date_issued":"2025","date_published":"2025","updated_at":"2026-11-19T06:53:34Z","subjects":["Environmental engineering"],"languages":["en"],"rights":["Copyright © 2025 the author(s). Theses may be used for non-commercial research, educational, or related academic purposes only. Such uses include personal study, distribution to students, research and scholarship. Theses may only be shared by linking to the Carleton University Institutional Repository and no part may be copied without proper attribution to the author; no part may be used for commercial purposes directly or indirectly via a for-profit platform; no adaptation or derivative works are permitted without consent from the copyright owner."],"rights_urls":[],"identifier_entries":[{"key":"dc:identifier.uri","label":"Identifier URI","values":["https://hdl.handle.net/20.500.14718/44036"],"render_values":[{"text":"https://hdl.handle.net/20.500.14718/44036","href":"https://hdl.handle.net/20.500.14718/44036","code":true}]}],"person_identifier_entries":[]},"links":{"outbound_url":"https://doi.org/10.22215/etd/2025-16669","outbound_label":"DOI","outbound_source":"dc:identifier.doi","record_url":"https://doi.org/10.22215/etd/2025-16669","record_label":"Repository record","record_kind":"doi","record_source":"dc:identifier.doi","access_status":null,"embargo_until":null,"access_note":null},"oai_pmh_record":{"url":"https://union.ndltd.org/oai-pmh/?verb=GetRecord&metadataPrefix=oai_dc&identifier=oai%3Aunion.ndltd.org%3Arepo%3Acarleton%3Aoai%3Acarleton.scholaris.ca%3A20.500.14718%2F44036","prefix":"oai_dc"},"source_record":{"url":"https://carleton.scholaris.ca/server/oai/request?verb=GetRecord&metadataPrefix=dim&identifier=oai%3Acarleton.scholaris.ca%3A20.500.14718%2F44036","prefix":"dim"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:creator","label":"Author","values":["Jeaurond, Zoé"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2025-07-31T18:39:39Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2025-07-31T18:39:39Z"]},{"key":"dc:date.issued","label":"Date","values":["2025"]},{"key":"dc:publisher","label":"Institution","values":["Carleton University"]},{"key":"dc:type","label":"Dc Type","values":["thesis"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Engineering, Environmental"]},{"key":"thesis:degree_level","label":"Degree Level","values":["Master's"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Master of Applied Science (M.App.Sc.)"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject.lcsh","label":"Dc Subject Lcsh","values":["Environmental engineering"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language.iso","label":"Language (ISO)","values":["en"]},{"key":"dc:rights","label":"Dc Rights","values":["Copyright © 2025 the author(s). Theses may be used for non-commercial research, educational, or related academic purposes only. Such uses include personal study, distribution to students, research and scholarship. Theses may only be shared by linking to the Carleton University Institutional Repository and no part may be copied without proper attribution to the author; no part may be used for commercial purposes directly or indirectly via a for-profit platform; no adaptation or derivative works are permitted without consent from the copyright owner."]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.doi","label":"DOI","values":["10.22215/etd/2025-16669"]},{"key":"dc:identifier.uri","label":"Identifier URI","values":["https://hdl.handle.net/20.500.14718/44036"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["Biofiltration is a sustainable and effective method in drinking water treatment, yet operational parameters are often adopted from conventional filtration without validation. This two-year study at the Britannia and Lemieux Island Water Purification Plants evaluates biofiltration performance and backwashing strategies under full-scale conditions. Key metrics include floc retention turbidity, unit filter run volume (UFRV), dissolved organic carbon (DOC) removal, and the effects of backwash methods. Seasonal changes, particularly colder temperatures, increased solids accumulation, indicating a need for adaptive backwashing. Reduced air scour durations maintained floc retention while improving efficiency. Findings suggest conventional turbidity thresholds (<60 NTU) may be too conservative; increasing to 120 NTU or using site-specific limits may be more appropriate. While air scouring removed more floc, hydraulic backwashing maintained better DOC removal. These results demonstrate the unique behaviour of biofilters, advocating for revised operational guidelines and tailored monitoring to optimize performance and ensure effective treatment outcomes."]},{"key":"dc:title","label":"Title","values":["Full-Scale Drinking Water Filter Assessments: Mapping Traditional and Novel Methods to Biofilter Health"]},{"key":"local:lac.licence","label":"Local Lac Licence","values":["true"]},{"key":"others:access_status","label":"Others Access Status","values":["open.access"]}]}],"canonical_facts":{"dc:creator":["Jeaurond, Zoé"],"dc:date.accessioned":["2025-07-31T18:39:39Z"],"dc:date.available":["2025-07-31T18:39:39Z"],"dc:date.issued":["2025"],"dc:description.abstract":["Biofiltration is a sustainable and effective method in drinking water treatment, yet operational parameters are often adopted from conventional filtration without validation. This two-year study at the Britannia and Lemieux Island Water Purification Plants evaluates biofiltration performance and backwashing strategies under full-scale conditions. Key metrics include floc retention turbidity, unit filter run volume (UFRV), dissolved organic carbon (DOC) removal, and the effects of backwash methods. Seasonal changes, particularly colder temperatures, increased solids accumulation, indicating a need for adaptive backwashing. Reduced air scour durations maintained floc retention while improving efficiency. Findings suggest conventional turbidity thresholds (<60 NTU) may be too conservative; increasing to 120 NTU or using site-specific limits may be more appropriate. While air scouring removed more floc, hydraulic backwashing maintained better DOC removal. These results demonstrate the unique behaviour of biofilters, advocating for revised operational guidelines and tailored monitoring to optimize performance and ensure effective treatment outcomes."],"dc:identifier.doi":["10.22215/etd/2025-16669"],"dc:identifier.uri":["https://hdl.handle.net/20.500.14718/44036"],"dc:language.iso":["en"],"dc:publisher":["Carleton University"],"dc:rights":["Copyright © 2025 the author(s). Theses may be used for non-commercial research, educational, or related academic purposes only. Such uses include personal study, distribution to students, research and scholarship. Theses may only be shared by linking to the Carleton University Institutional Repository and no part may be copied without proper attribution to the author; no part may be used for commercial purposes directly or indirectly via a for-profit platform; no adaptation or derivative works are permitted without consent from the copyright owner."],"dc:subject.lcsh":["Environmental engineering"],"dc:title":["Full-Scale Drinking Water Filter Assessments: Mapping Traditional and Novel Methods to Biofilter Health"],"dc:type":["thesis"],"local:lac.licence":["true"],"others:access_status":["open.access"],"thesis:degree_discipline":["Engineering, Environmental"],"thesis:degree_level":["Master's"],"thesis:degree_name":["Master of Applied Science (M.App.Sc.)"]},"updated_at":"2026-11-19T06:53:34Z"}