{"id":{"repo_id":"carleton","oai_identifier":"oai:carleton.scholaris.ca:20.500.14718/44736"},"canonical_url":"https://search.ndltd.org/etd/carleton/oai:carleton.scholaris.ca:20.500.14718/44736","repository":{"repo_id":"carleton","name":"Carleton University","base_url":"https://carleton.scholaris.ca/server/oai/request"},"display":{"title":"Resilience of Net-Zero Retrofits during Extreme Weather Events: A Phased Approach","abstract":"Extreme weather events are projected to increase in both frequency and severity, highlighting the need for adaptable building retrofit strategies. This thesis presents a novel approach to resilience modeling by evaluating the performance of various net-zero retrofit measures under simulated extreme weather scenarios. Serving as the case study, a building energy model using EnergyPlus was developed for a four-unit townhome that underwent phased net-zero retrofits. Each retrofit phase was tested against three distinct extreme weather events using an open-source modeling framework (genEPJ). Results demonstrate that the most effective resilience improvement was achieved through the installation of an air source heat pump, which enhanced cooling capacity and maintained livable indoor temperatures during the two heating events. This research underscores the value of resilience-focused modeling in retrofit planning and provides a practical framework for assessing and improving the performance of existing buildings under future climate extremes.","abstract_html":"Extreme weather events are projected to increase in both frequency and severity, highlighting the need for adaptable building retrofit strategies. This thesis presents a novel approach to resilience modeling by evaluating the performance of various net-zero retrofit measures under simulated extreme weather scenarios. Serving as the case study, a building energy model using EnergyPlus was developed for a four-unit townhome that underwent phased net-zero retrofits. Each retrofit phase was tested against three distinct extreme weather events using an open-source modeling framework (genEPJ). Results demonstrate that the most effective resilience improvement was achieved through the installation of an air source heat pump, which enhanced cooling capacity and maintained livable indoor temperatures during the two heating events. This research underscores the value of resilience-focused modeling in retrofit planning and provides a practical framework for assessing and improving the performance of existing buildings under future climate extremes.","abstract_has_math":false,"creators":["Bailey, Nicholas Connor"],"institution":"Carleton University","degree_name":"Master of Applied Science (M.App.Sc.)","degree_level":"Master's","degree_discipline":"Engineering, Building","degree_department":null,"school":null,"contributors":[],"advisors":[],"committee_chairs":[],"committee_members":[],"year":2025,"date_issued":"2025","date_published":"2025","updated_at":"2026-11-19T07:07:28Z","subjects":["Civil engineering","Engineering"],"languages":["en"],"rights":["Copyright © 2025 the author(s). Theses may be used for non-commercial research, educational, or related academic purposes only. Such uses include personal study, distribution to students, research and scholarship. Theses may only be shared by linking to the Carleton University Institutional Repository and no part may be copied without proper attribution to the author; no part may be used for commercial purposes directly or indirectly via a for-profit platform; no adaptation or derivative works are permitted without consent from the copyright owner."],"rights_urls":[],"identifier_entries":[{"key":"dc:identifier.uri","label":"Identifier URI","values":["https://hdl.handle.net/20.500.14718/44736"],"render_values":[{"text":"https://hdl.handle.net/20.500.14718/44736","href":"https://hdl.handle.net/20.500.14718/44736","code":true}]}],"person_identifier_entries":[]},"links":{"outbound_url":"https://doi.org/10.22215/etd/2025-16709","outbound_label":"DOI","outbound_source":"dc:identifier.doi","record_url":"https://doi.org/10.22215/etd/2025-16709","record_label":"Repository record","record_kind":"doi","record_source":"dc:identifier.doi","access_status":null,"embargo_until":null,"access_note":null},"source_record":{"url":"https://carleton.scholaris.ca/server/oai/request?verb=GetRecord&metadataPrefix=dim&identifier=oai%3Acarleton.scholaris.ca%3A20.500.14718%2F44736","prefix":"dim"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:creator","label":"Author","values":["Bailey, Nicholas Connor"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2026-01-19T15:07:38Z"]},{"key":"dc:date.issued","label":"Date","values":["2025"]},{"key":"dc:publisher","label":"Institution","values":["Carleton University"]},{"key":"dc:type","label":"Dc Type","values":["thesis"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Engineering, Building"]},{"key":"thesis:degree_level","label":"Degree Level","values":["Master's"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Master of Applied Science (M.App.Sc.)"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject.lcsh","label":"Dc Subject Lcsh","values":["Civil engineering","Engineering"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language.iso","label":"Language (ISO)","values":["en"]},{"key":"dc:rights","label":"Dc Rights","values":["Copyright © 2025 the author(s). Theses may be used for non-commercial research, educational, or related academic purposes only. Such uses include personal study, distribution to students, research and scholarship. Theses may only be shared by linking to the Carleton University Institutional Repository and no part may be copied without proper attribution to the author; no part may be used for commercial purposes directly or indirectly via a for-profit platform; no adaptation or derivative works are permitted without consent from the copyright owner."]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.doi","label":"DOI","values":["10.22215/etd/2025-16709"]},{"key":"dc:identifier.uri","label":"Identifier URI","values":["https://hdl.handle.net/20.500.14718/44736"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["Extreme weather events are projected to increase in both frequency and severity, highlighting the need for adaptable building retrofit strategies. This thesis presents a novel approach to resilience modeling by evaluating the performance of various net-zero retrofit measures under simulated extreme weather scenarios. Serving as the case study, a building energy model using EnergyPlus was developed for a four-unit townhome that underwent phased net-zero retrofits. Each retrofit phase was tested against three distinct extreme weather events using an open-source modeling framework (genEPJ). Results demonstrate that the most effective resilience improvement was achieved through the installation of an air source heat pump, which enhanced cooling capacity and maintained livable indoor temperatures during the two heating events. This research underscores the value of resilience-focused modeling in retrofit planning and provides a practical framework for assessing and improving the performance of existing buildings under future climate extremes."]},{"key":"dc:title","label":"Title","values":["Resilience of Net-Zero Retrofits during Extreme Weather Events: A Phased Approach"]},{"key":"local:lac.licence","label":"Local Lac Licence","values":["true"]},{"key":"others:access_status","label":"Others Access Status","values":["open.access"]}]}],"canonical_facts":{"dc:creator":["Bailey, Nicholas Connor"],"dc:date.accessioned":["2026-01-19T15:07:38Z"],"dc:date.issued":["2025"],"dc:description.abstract":["Extreme weather events are projected to increase in both frequency and severity, highlighting the need for adaptable building retrofit strategies. This thesis presents a novel approach to resilience modeling by evaluating the performance of various net-zero retrofit measures under simulated extreme weather scenarios. Serving as the case study, a building energy model using EnergyPlus was developed for a four-unit townhome that underwent phased net-zero retrofits. Each retrofit phase was tested against three distinct extreme weather events using an open-source modeling framework (genEPJ). Results demonstrate that the most effective resilience improvement was achieved through the installation of an air source heat pump, which enhanced cooling capacity and maintained livable indoor temperatures during the two heating events. This research underscores the value of resilience-focused modeling in retrofit planning and provides a practical framework for assessing and improving the performance of existing buildings under future climate extremes."],"dc:identifier.doi":["10.22215/etd/2025-16709"],"dc:identifier.uri":["https://hdl.handle.net/20.500.14718/44736"],"dc:language.iso":["en"],"dc:publisher":["Carleton University"],"dc:rights":["Copyright © 2025 the author(s). Theses may be used for non-commercial research, educational, or related academic purposes only. Such uses include personal study, distribution to students, research and scholarship. Theses may only be shared by linking to the Carleton University Institutional Repository and no part may be copied without proper attribution to the author; no part may be used for commercial purposes directly or indirectly via a for-profit platform; no adaptation or derivative works are permitted without consent from the copyright owner."],"dc:subject.lcsh":["Civil engineering","Engineering"],"dc:title":["Resilience of Net-Zero Retrofits during Extreme Weather Events: A Phased Approach"],"dc:type":["thesis"],"local:lac.licence":["true"],"others:access_status":["open.access"],"thesis:degree_discipline":["Engineering, Building"],"thesis:degree_level":["Master's"],"thesis:degree_name":["Master of Applied Science (M.App.Sc.)"]},"updated_at":"2026-11-19T07:07:28Z"}