{"id":{"repo_id":"carleton","oai_identifier":"oai:carleton.scholaris.ca:20.500.14718/44765"},"canonical_url":"https://search.ndltd.org/etd/carleton/oai:carleton.scholaris.ca:20.500.14718/44765","repository":{"repo_id":"carleton","name":"Carleton University","base_url":"https://carleton.scholaris.ca/server/oai/request"},"display":{"title":"A TRNSYS Modelling Study to Investigate the Performance of a Steel-Structured Commercial Building Undergoing Panelized Exterior Retrofits in Future Climate Scenarios","abstract":"Prefabricated panelized exterior retrofits (PPERs) can significantly reduce the thermal energy demand of existing buildings. However, PPERs remain largely untested at scale in the Canadian commercial building sector. This thesis aims to explore how PPERs and the future effects of climate change affect thermal energy consumption, resilience, and comfort in steel-structured commercial buildings. To this end, a building energy model of a case-study building was calibrated using monitored power data and a parametric energy model representing a steel-structured commercial building archetype was created in TRNSYS and MATLAB. The simulation results show that this building archetype benefits from a PPER and can significantly reduce net thermal energy consumption. However, certain scenarios result in an increased cooling demand due to the reduction in heat loss through the envelope. The PPER also improves the thermal resilience in most scenarios due to the upgraded envelope’s improved ability to resist extreme temperatures.","abstract_html":"Prefabricated panelized exterior retrofits (PPERs) can significantly reduce the thermal energy demand of existing buildings. However, PPERs remain largely untested at scale in the Canadian commercial building sector. This thesis aims to explore how PPERs and the future effects of climate change affect thermal energy consumption, resilience, and comfort in steel-structured commercial buildings. To this end, a building energy model of a case-study building was calibrated using monitored power data and a parametric energy model representing a steel-structured commercial building archetype was created in TRNSYS and MATLAB. The simulation results show that this building archetype benefits from a PPER and can significantly reduce net thermal energy consumption. However, certain scenarios result in an increased cooling demand due to the reduction in heat loss through the envelope. The PPER also improves the thermal resilience in most scenarios due to the upgraded envelope’s improved ability to resist extreme temperatures.","abstract_has_math":false,"creators":["Rudnicki, Isaac Stephen"],"institution":"Carleton University","degree_name":"Master of Applied Science (M.App.Sc.)","degree_level":"Master's","degree_discipline":"Engineering, Building","degree_department":null,"school":null,"contributors":[],"advisors":[],"committee_chairs":[],"committee_members":[],"year":2025,"date_issued":"2025","date_published":"2025","updated_at":"2026-11-19T06:53:34Z","subjects":["Force and energy"],"languages":["en"],"rights":["Copyright © 2025 the author(s). Theses may be used for non-commercial research, educational, or related academic purposes only. Such uses include personal study, distribution to students, research and scholarship. Theses may only be shared by linking to the Carleton University Institutional Repository and no part may be copied without proper attribution to the author; no part may be used for commercial purposes directly or indirectly via a for-profit platform; no adaptation or derivative works are permitted without consent from the copyright owner."],"rights_urls":[],"identifier_entries":[{"key":"dc:identifier.doi","label":"DOI","values":["10.22215/etd/2025-16738"],"render_values":[{"text":"10.22215/etd/2025-16738","href":"https://doi.org/10.22215/etd/2025-16738","code":true}]}],"person_identifier_entries":[]},"links":{"outbound_url":"https://hdl.handle.net/20.500.14718/44765","outbound_label":"Handle","outbound_source":"dc:identifier.uri","record_url":"https://hdl.handle.net/20.500.14718/44765","record_label":"Repository record","record_kind":"handle","record_source":"dc:identifier.uri","download_url":null,"download_label":null,"download_source":null,"access_status":null,"embargo_until":null,"access_note":null},"source_record":{"url":"https://carleton.scholaris.ca/server/oai/request?verb=GetRecord&metadataPrefix=dim&identifier=oai%3Acarleton.scholaris.ca%3A20.500.14718%2F44765","prefix":"dim"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:creator","label":"Author","values":["Rudnicki, Isaac Stephen"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2026-01-19T15:08:16Z"]},{"key":"dc:date.issued","label":"Date","values":["2025"]},{"key":"dc:publisher","label":"Institution","values":["Carleton University"]},{"key":"dc:type","label":"Dc Type","values":["thesis"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Engineering, Building"]},{"key":"thesis:degree_level","label":"Degree Level","values":["Master's"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Master of Applied Science (M.App.Sc.)"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject.lcsh","label":"Dc Subject Lcsh","values":["Force and energy"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language.iso","label":"Language (ISO)","values":["en"]},{"key":"dc:rights","label":"Dc Rights","values":["Copyright © 2025 the author(s). Theses may be used for non-commercial research, educational, or related academic purposes only. Such uses include personal study, distribution to students, research and scholarship. Theses may only be shared by linking to the Carleton University Institutional Repository and no part may be copied without proper attribution to the author; no part may be used for commercial purposes directly or indirectly via a for-profit platform; no adaptation or derivative works are permitted without consent from the copyright owner."]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.doi","label":"DOI","values":["10.22215/etd/2025-16738"]},{"key":"dc:identifier.uri","label":"Identifier URI","values":["https://hdl.handle.net/20.500.14718/44765"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["Prefabricated panelized exterior retrofits (PPERs) can significantly reduce the thermal energy demand of existing buildings. However, PPERs remain largely untested at scale in the Canadian commercial building sector. This thesis aims to explore how PPERs and the future effects of climate change affect thermal energy consumption, resilience, and comfort in steel-structured commercial buildings. To this end, a building energy model of a case-study building was calibrated using monitored power data and a parametric energy model representing a steel-structured commercial building archetype was created in TRNSYS and MATLAB. The simulation results show that this building archetype benefits from a PPER and can significantly reduce net thermal energy consumption. However, certain scenarios result in an increased cooling demand due to the reduction in heat loss through the envelope. The PPER also improves the thermal resilience in most scenarios due to the upgraded envelope’s improved ability to resist extreme temperatures."]},{"key":"dc:title","label":"Title","values":["A TRNSYS Modelling Study to Investigate the Performance of a Steel-Structured Commercial Building Undergoing Panelized Exterior Retrofits in Future Climate Scenarios"]},{"key":"local:lac.licence","label":"Local Lac Licence","values":["true"]},{"key":"others:access_status","label":"Others Access Status","values":["open.access"]}]}],"canonical_facts":{"dc:creator":["Rudnicki, Isaac Stephen"],"dc:date.accessioned":["2026-01-19T15:08:16Z"],"dc:date.issued":["2025"],"dc:description.abstract":["Prefabricated panelized exterior retrofits (PPERs) can significantly reduce the thermal energy demand of existing buildings. However, PPERs remain largely untested at scale in the Canadian commercial building sector. This thesis aims to explore how PPERs and the future effects of climate change affect thermal energy consumption, resilience, and comfort in steel-structured commercial buildings. To this end, a building energy model of a case-study building was calibrated using monitored power data and a parametric energy model representing a steel-structured commercial building archetype was created in TRNSYS and MATLAB. The simulation results show that this building archetype benefits from a PPER and can significantly reduce net thermal energy consumption. However, certain scenarios result in an increased cooling demand due to the reduction in heat loss through the envelope. The PPER also improves the thermal resilience in most scenarios due to the upgraded envelope’s improved ability to resist extreme temperatures."],"dc:identifier.doi":["10.22215/etd/2025-16738"],"dc:identifier.uri":["https://hdl.handle.net/20.500.14718/44765"],"dc:language.iso":["en"],"dc:publisher":["Carleton University"],"dc:rights":["Copyright © 2025 the author(s). Theses may be used for non-commercial research, educational, or related academic purposes only. Such uses include personal study, distribution to students, research and scholarship. Theses may only be shared by linking to the Carleton University Institutional Repository and no part may be copied without proper attribution to the author; no part may be used for commercial purposes directly or indirectly via a for-profit platform; no adaptation or derivative works are permitted without consent from the copyright owner."],"dc:subject.lcsh":["Force and energy"],"dc:title":["A TRNSYS Modelling Study to Investigate the Performance of a Steel-Structured Commercial Building Undergoing Panelized Exterior Retrofits in Future Climate Scenarios"],"dc:type":["thesis"],"local:lac.licence":["true"],"others:access_status":["open.access"],"thesis:degree_discipline":["Engineering, Building"],"thesis:degree_level":["Master's"],"thesis:degree_name":["Master of Applied Science (M.App.Sc.)"]},"updated_at":"2026-11-19T06:53:34Z"}