{"id":{"repo_id":"carleton","oai_identifier":"oai:carleton.scholaris.ca:20.500.14718/44916"},"canonical_url":"https://search.ndltd.org/etd/carleton/oai:carleton.scholaris.ca:20.500.14718/44916","repository":{"repo_id":"carleton","name":"Carleton University","base_url":"https://carleton.scholaris.ca/server/oai/request"},"display":{"title":"Calibration and Performance of Residential Deep Energy Retrofits Under Future Climate Projections Using Building Energy and Hygrothermal Models","abstract":"A deep energy retrofit residential retrofit should reduce the building’s energy use by at least 60% by upgrading the building conditioning systems and envelopes. As deep energy retrofits become more common and energy savings validated, the impacts of climate change and extreme weather events make it increasingly important to evaluate the longterm resiliency when considering the liveability of the building. The objective of this research was to develop calibrated energy and hygrothermal models based on a retrofitted building and assess if energy savings, durability, and resilience are maintained using future weather files. Overall energy use dropped in future weather cases and retrofit energy savings were maintained. Thermal resilience improved in the retrofitted building, but there are overheating risks associated with power outage scenarios in the cooling season. Retrofitted assemblies showing little or no mould risk, while the un-retrofitted assembly had a mould risk of up to 5 in specific scenarios.","abstract_html":"A deep energy retrofit residential retrofit should reduce the building’s energy use by at least 60% by upgrading the building conditioning systems and envelopes. As deep energy retrofits become more common and energy savings validated, the impacts of climate change and extreme weather events make it increasingly important to evaluate the longterm resiliency when considering the liveability of the building. The objective of this research was to develop calibrated energy and hygrothermal models based on a retrofitted building and assess if energy savings, durability, and resilience are maintained using future weather files. Overall energy use dropped in future weather cases and retrofit energy savings were maintained. Thermal resilience improved in the retrofitted building, but there are overheating risks associated with power outage scenarios in the cooling season. Retrofitted assemblies showing little or no mould risk, while the un-retrofitted assembly had a mould risk of up to 5 in specific scenarios.","abstract_has_math":false,"creators":["Zagar, Myles Freeman"],"institution":"Carleton University","degree_name":"Master of Applied Science (M.App.Sc.)","degree_level":"Master's","degree_discipline":"Engineering, Mechanical","degree_department":null,"school":null,"contributors":[],"advisors":[],"committee_chairs":[],"committee_members":[],"year":2025,"date_issued":"2025","date_published":"2025","updated_at":"2026-11-19T07:08:25Z","subjects":["Mechanical engineering"],"languages":["en"],"rights":["Copyright © 2025 the author(s). Theses may be used for non-commercial research, educational, or related academic purposes only. Such uses include personal study, distribution to students, research and scholarship. Theses may only be shared by linking to the Carleton University Institutional Repository and no part may be copied without proper attribution to the author; no part may be used for commercial purposes directly or indirectly via a for-profit platform; no adaptation or derivative works are permitted without consent from the copyright owner."],"rights_urls":[],"identifier_entries":[{"key":"dc:identifier.doi","label":"DOI","values":["10.22215/etd/2025-16889"],"render_values":[{"text":"10.22215/etd/2025-16889","href":"https://doi.org/10.22215/etd/2025-16889","code":true}]}],"person_identifier_entries":[]},"links":{"outbound_url":"https://hdl.handle.net/20.500.14718/44916","outbound_label":"Handle","outbound_source":"dc:identifier.uri","record_url":"https://hdl.handle.net/20.500.14718/44916","record_label":"Repository record","record_kind":"handle","record_source":"dc:identifier.uri","download_url":null,"download_label":null,"download_source":null,"access_status":null,"embargo_until":null,"access_note":null},"source_record":{"url":"https://carleton.scholaris.ca/server/oai/request?verb=GetRecord&metadataPrefix=dim&identifier=oai%3Acarleton.scholaris.ca%3A20.500.14718%2F44916","prefix":"dim"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:creator","label":"Author","values":["Zagar, Myles Freeman"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2026-01-19T15:11:22Z"]},{"key":"dc:date.issued","label":"Date","values":["2025"]},{"key":"dc:publisher","label":"Institution","values":["Carleton University"]},{"key":"dc:type","label":"Dc Type","values":["thesis"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Engineering, Mechanical"]},{"key":"thesis:degree_level","label":"Degree Level","values":["Master's"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Master of Applied Science (M.App.Sc.)"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject.lcsh","label":"Dc Subject Lcsh","values":["Mechanical engineering"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language.iso","label":"Language (ISO)","values":["en"]},{"key":"dc:rights","label":"Dc Rights","values":["Copyright © 2025 the author(s). Theses may be used for non-commercial research, educational, or related academic purposes only. Such uses include personal study, distribution to students, research and scholarship. Theses may only be shared by linking to the Carleton University Institutional Repository and no part may be copied without proper attribution to the author; no part may be used for commercial purposes directly or indirectly via a for-profit platform; no adaptation or derivative works are permitted without consent from the copyright owner."]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.doi","label":"DOI","values":["10.22215/etd/2025-16889"]},{"key":"dc:identifier.uri","label":"Identifier URI","values":["https://hdl.handle.net/20.500.14718/44916"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["A deep energy retrofit residential retrofit should reduce the building’s energy use by at least 60% by upgrading the building conditioning systems and envelopes. As deep energy retrofits become more common and energy savings validated, the impacts of climate change and extreme weather events make it increasingly important to evaluate the longterm resiliency when considering the liveability of the building. The objective of this research was to develop calibrated energy and hygrothermal models based on a retrofitted building and assess if energy savings, durability, and resilience are maintained using future weather files. Overall energy use dropped in future weather cases and retrofit energy savings were maintained. Thermal resilience improved in the retrofitted building, but there are overheating risks associated with power outage scenarios in the cooling season. Retrofitted assemblies showing little or no mould risk, while the un-retrofitted assembly had a mould risk of up to 5 in specific scenarios."]},{"key":"dc:title","label":"Title","values":["Calibration and Performance of Residential Deep Energy Retrofits Under Future Climate Projections Using Building Energy and Hygrothermal Models"]},{"key":"local:lac.licence","label":"Local Lac Licence","values":["true"]},{"key":"others:access_status","label":"Others Access Status","values":["open.access"]}]}],"canonical_facts":{"dc:creator":["Zagar, Myles Freeman"],"dc:date.accessioned":["2026-01-19T15:11:22Z"],"dc:date.issued":["2025"],"dc:description.abstract":["A deep energy retrofit residential retrofit should reduce the building’s energy use by at least 60% by upgrading the building conditioning systems and envelopes. As deep energy retrofits become more common and energy savings validated, the impacts of climate change and extreme weather events make it increasingly important to evaluate the longterm resiliency when considering the liveability of the building. The objective of this research was to develop calibrated energy and hygrothermal models based on a retrofitted building and assess if energy savings, durability, and resilience are maintained using future weather files. Overall energy use dropped in future weather cases and retrofit energy savings were maintained. Thermal resilience improved in the retrofitted building, but there are overheating risks associated with power outage scenarios in the cooling season. Retrofitted assemblies showing little or no mould risk, while the un-retrofitted assembly had a mould risk of up to 5 in specific scenarios."],"dc:identifier.doi":["10.22215/etd/2025-16889"],"dc:identifier.uri":["https://hdl.handle.net/20.500.14718/44916"],"dc:language.iso":["en"],"dc:publisher":["Carleton University"],"dc:rights":["Copyright © 2025 the author(s). Theses may be used for non-commercial research, educational, or related academic purposes only. Such uses include personal study, distribution to students, research and scholarship. Theses may only be shared by linking to the Carleton University Institutional Repository and no part may be copied without proper attribution to the author; no part may be used for commercial purposes directly or indirectly via a for-profit platform; no adaptation or derivative works are permitted without consent from the copyright owner."],"dc:subject.lcsh":["Mechanical engineering"],"dc:title":["Calibration and Performance of Residential Deep Energy Retrofits Under Future Climate Projections Using Building Energy and Hygrothermal Models"],"dc:type":["thesis"],"local:lac.licence":["true"],"others:access_status":["open.access"],"thesis:degree_discipline":["Engineering, Mechanical"],"thesis:degree_level":["Master's"],"thesis:degree_name":["Master of Applied Science (M.App.Sc.)"]},"updated_at":"2026-11-19T07:08:25Z"}