{"id":{"repo_id":"carleton","oai_identifier":"oai:carleton.scholaris.ca:20.500.14718/45110"},"canonical_url":"https://search.ndltd.org/etd/carleton/oai:carleton.scholaris.ca:20.500.14718/45110","repository":{"repo_id":"carleton","name":"Carleton University","base_url":"https://carleton.scholaris.ca/server/oai/request"},"display":{"title":"Deep Learning with Pressure-Sensitive Mats for Polysomnography","abstract":"Polysomnography, plays a crucial role in diagnosing a wide range of sleep-related conditions, including obstructive sleep apnea and central sleep apnea. However, traditional polysomnography requires lab setups with multiple sensors in an overnight study, which makes it resource-intensive and inconvenient for both patients and healthcare providers. In this work, we investigated whether combining pressure-sensitive mat data with other minimally invasive sensors and deep learning techniques can provide accurate and reliable analyses comparable to traditional polysomnography setups. We finetuned Vision Transformers for accurate sleep position estimation using pressure-sensitive mat data, illustrating their adaptability from natural images to clinical applications. We developed a multimodal deep learning approach with ImageBind, combining pressure-sensitive mat data and electrooculography signals to improve sleep stage classification by capturing complementary information across modalities. Lastly, we demonstrated that by fusing knowledge of sleep position with respiratory effort data, we can improve the detection of sleep apnea and hypopnea.","abstract_html":"Polysomnography, plays a crucial role in diagnosing a wide range of sleep-related conditions, including obstructive sleep apnea and central sleep apnea. However, traditional polysomnography requires lab setups with multiple sensors in an overnight study, which makes it resource-intensive and inconvenient for both patients and healthcare providers. In this work, we investigated whether combining pressure-sensitive mat data with other minimally invasive sensors and deep learning techniques can provide accurate and reliable analyses comparable to traditional polysomnography setups. We finetuned Vision Transformers for accurate sleep position estimation using pressure-sensitive mat data, illustrating their adaptability from natural images to clinical applications. We developed a multimodal deep learning approach with ImageBind, combining pressure-sensitive mat data and electrooculography signals to improve sleep stage classification by capturing complementary information across modalities. Lastly, we demonstrated that by fusing knowledge of sleep position with respiratory effort data, we can improve the detection of sleep apnea and hypopnea.","abstract_has_math":false,"creators":["Papillon, Olivier Lucas"],"institution":"Carleton University","degree_name":"Master of Applied Science (M.App.Sc.)","degree_level":"Master's","degree_discipline":"Engineering, Electrical and Computer","degree_department":null,"school":null,"contributors":[],"advisors":[],"committee_chairs":[],"committee_members":[],"year":2026,"date_issued":"2026","date_published":"2026","updated_at":"2026-11-19T07:03:56Z","subjects":["Artificial intelligence","Biomedical engineering","Electrical engineering"],"languages":["en"],"rights":["Copyright © 2025 the author(s). Theses may be used for non-commercial research, educational, or related academic purposes only. Such uses include personal study, distribution to students, research and scholarship. Theses may only be shared by linking to the Carleton University Institutional Repository and no part may be copied without proper attribution to the author; no part may be used for commercial purposes directly or indirectly via a for-profit platform; no adaptation or derivative works are permitted without consent from the copyright owner."],"rights_urls":[],"identifier_entries":[{"key":"dc:identifier.doi","label":"DOI","values":["10.22215/etd/2025-16953"],"render_values":[{"text":"10.22215/etd/2025-16953","href":"https://doi.org/10.22215/etd/2025-16953","code":true}]}],"person_identifier_entries":[]},"links":{"outbound_url":"https://hdl.handle.net/20.500.14718/45110","outbound_label":"Handle","outbound_source":"dc:identifier.uri","record_url":"https://hdl.handle.net/20.500.14718/45110","record_label":"Repository record","record_kind":"handle","record_source":"dc:identifier.uri","download_url":null,"download_label":null,"download_source":null,"access_status":null,"embargo_until":null,"access_note":null},"source_record":{"url":"https://carleton.scholaris.ca/server/oai/request?verb=GetRecord&metadataPrefix=dim&identifier=oai%3Acarleton.scholaris.ca%3A20.500.14718%2F45110","prefix":"dim"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:creator","label":"Author","values":["Papillon, Olivier Lucas"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2026-07-22T18:38:02Z"]},{"key":"dc:date.issued","label":"Date","values":["2026"]},{"key":"dc:publisher","label":"Institution","values":["Carleton University"]},{"key":"dc:type","label":"Dc Type","values":["thesis"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Engineering, Electrical and Computer"]},{"key":"thesis:degree_level","label":"Degree Level","values":["Master's"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Master of Applied Science (M.App.Sc.)"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject.lcsh","label":"Dc Subject Lcsh","values":["Artificial intelligence","Biomedical engineering","Electrical engineering"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language.iso","label":"Language (ISO)","values":["en"]},{"key":"dc:rights","label":"Dc Rights","values":["Copyright © 2025 the author(s). Theses may be used for non-commercial research, educational, or related academic purposes only. Such uses include personal study, distribution to students, research and scholarship. Theses may only be shared by linking to the Carleton University Institutional Repository and no part may be copied without proper attribution to the author; no part may be used for commercial purposes directly or indirectly via a for-profit platform; no adaptation or derivative works are permitted without consent from the copyright owner."]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.doi","label":"DOI","values":["10.22215/etd/2025-16953"]},{"key":"dc:identifier.uri","label":"Identifier URI","values":["https://hdl.handle.net/20.500.14718/45110"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["Polysomnography, plays a crucial role in diagnosing a wide range of sleep-related conditions, including obstructive sleep apnea and central sleep apnea. However, traditional polysomnography requires lab setups with multiple sensors in an overnight study, which makes it resource-intensive and inconvenient for both patients and healthcare providers. In this work, we investigated whether combining pressure-sensitive mat data with other minimally invasive sensors and deep learning techniques can provide accurate and reliable analyses comparable to traditional polysomnography setups. We finetuned Vision Transformers for accurate sleep position estimation using pressure-sensitive mat data, illustrating their adaptability from natural images to clinical applications. We developed a multimodal deep learning approach with ImageBind, combining pressure-sensitive mat data and electrooculography signals to improve sleep stage classification by capturing complementary information across modalities. Lastly, we demonstrated that by fusing knowledge of sleep position with respiratory effort data, we can improve the detection of sleep apnea and hypopnea."]},{"key":"dc:title","label":"Title","values":["Deep Learning with Pressure-Sensitive Mats for Polysomnography"]},{"key":"local:lac.licence","label":"Local Lac Licence","values":["true"]},{"key":"others:access_status","label":"Others Access Status","values":["open.access"]}]}],"canonical_facts":{"dc:creator":["Papillon, Olivier Lucas"],"dc:date.accessioned":["2026-07-22T18:38:02Z"],"dc:date.issued":["2026"],"dc:description.abstract":["Polysomnography, plays a crucial role in diagnosing a wide range of sleep-related conditions, including obstructive sleep apnea and central sleep apnea. However, traditional polysomnography requires lab setups with multiple sensors in an overnight study, which makes it resource-intensive and inconvenient for both patients and healthcare providers. In this work, we investigated whether combining pressure-sensitive mat data with other minimally invasive sensors and deep learning techniques can provide accurate and reliable analyses comparable to traditional polysomnography setups. We finetuned Vision Transformers for accurate sleep position estimation using pressure-sensitive mat data, illustrating their adaptability from natural images to clinical applications. We developed a multimodal deep learning approach with ImageBind, combining pressure-sensitive mat data and electrooculography signals to improve sleep stage classification by capturing complementary information across modalities. Lastly, we demonstrated that by fusing knowledge of sleep position with respiratory effort data, we can improve the detection of sleep apnea and hypopnea."],"dc:identifier.doi":["10.22215/etd/2025-16953"],"dc:identifier.uri":["https://hdl.handle.net/20.500.14718/45110"],"dc:language.iso":["en"],"dc:publisher":["Carleton University"],"dc:rights":["Copyright © 2025 the author(s). Theses may be used for non-commercial research, educational, or related academic purposes only. Such uses include personal study, distribution to students, research and scholarship. Theses may only be shared by linking to the Carleton University Institutional Repository and no part may be copied without proper attribution to the author; no part may be used for commercial purposes directly or indirectly via a for-profit platform; no adaptation or derivative works are permitted without consent from the copyright owner."],"dc:subject.lcsh":["Artificial intelligence","Biomedical engineering","Electrical engineering"],"dc:title":["Deep Learning with Pressure-Sensitive Mats for Polysomnography"],"dc:type":["thesis"],"local:lac.licence":["true"],"others:access_status":["open.access"],"thesis:degree_discipline":["Engineering, Electrical and Computer"],"thesis:degree_level":["Master's"],"thesis:degree_name":["Master of Applied Science (M.App.Sc.)"]},"updated_at":"2026-11-19T07:03:56Z"}