{"id":{"repo_id":"carleton","oai_identifier":"oai:carleton.scholaris.ca:20.500.14718/45115"},"canonical_url":"https://search.ndltd.org/etd/carleton/oai:carleton.scholaris.ca:20.500.14718/45115","repository":{"repo_id":"carleton","name":"Carleton University","base_url":"https://carleton.scholaris.ca/server/oai/request"},"display":{"title":"Indoor Environmental Quality in Low-Income Housing: An Exploratory Field Study of Comfort in Ottawa","abstract":"Indoor environmental quality (IEQ) critically affects health and comfort, yet limited research has examined IEQ in low-income housing (LIH), which often houses more vulnerable populations. This thesis presents findings from an exploratory field investigation of 18 LIH units, combining multi-season monitoring, monthly surveys, walkthroughs, and semi-structured interviews. Sensors measured temperature, relative humidity, CO₂, PM₂.₅, and TVOCs, which were evaluated using guideline-based thresholds. Correlations and logistic regression assessed alignment between measured conditions and occupant-reported experiences. Thermal conditions were generally acceptable but showed weak alignment with occupant-reported thermal sensations. CO₂ and PM₂.₅ levels were typically within range, while TVOC concentrations varied. Low humidity was a persistent winter issue. Visual comfort was influenced by daylight, lighting distribution, and colour. Higher outdoor noise was associated with lower overall comfort, higher stress, and poorer sleep quality. Interviews highlighted non-IEQ safety and maintenance concerns. Findings informed low-cost, targeted strategies to improve comfort in LIH.","abstract_html":"Indoor environmental quality (IEQ) critically affects health and comfort, yet limited research has examined IEQ in low-income housing (LIH), which often houses more vulnerable populations. This thesis presents findings from an exploratory field investigation of 18 LIH units, combining multi-season monitoring, monthly surveys, walkthroughs, and semi-structured interviews. Sensors measured temperature, relative humidity, CO₂, PM₂.₅, and TVOCs, which were evaluated using guideline-based thresholds. Correlations and logistic regression assessed alignment between measured conditions and occupant-reported experiences. Thermal conditions were generally acceptable but showed weak alignment with occupant-reported thermal sensations. CO₂ and PM₂.₅ levels were typically within range, while TVOC concentrations varied. Low humidity was a persistent winter issue. Visual comfort was influenced by daylight, lighting distribution, and colour. Higher outdoor noise was associated with lower overall comfort, higher stress, and poorer sleep quality. Interviews highlighted non-IEQ safety and maintenance concerns. Findings informed low-cost, targeted strategies to improve comfort in LIH.","abstract_has_math":false,"creators":["Sewraj, Kala"],"institution":"Carleton University","degree_name":"Master of Applied Science (M.App.Sc.)","degree_level":"Master's","degree_discipline":"Engineering, Building","degree_department":null,"school":null,"contributors":[],"advisors":[],"committee_chairs":[],"committee_members":[],"year":2026,"date_issued":"2026","date_published":"2026","updated_at":"2026-11-19T07:07:19Z","subjects":["Buildings--Environmental","Buildings--Repair and construction"],"languages":["en"],"rights":["Copyright © 2025 the author(s). Theses may be used for non-commercial research, educational, or related academic purposes only. Such uses include personal study, distribution to students, research and scholarship. Theses may only be shared by linking to the Carleton University Institutional Repository and no part may be copied without proper attribution to the author; no part may be used for commercial purposes directly or indirectly via a for-profit platform; no adaptation or derivative works are permitted without consent from the copyright owner."],"rights_urls":[],"identifier_entries":[{"key":"dc:identifier.doi","label":"DOI","values":["10.22215/etd/2026-16958"],"render_values":[{"text":"10.22215/etd/2026-16958","href":"https://doi.org/10.22215/etd/2026-16958","code":true}]}],"person_identifier_entries":[]},"links":{"outbound_url":"https://hdl.handle.net/20.500.14718/45115","outbound_label":"Handle","outbound_source":"dc:identifier.uri","record_url":"https://hdl.handle.net/20.500.14718/45115","record_label":"Repository record","record_kind":"handle","record_source":"dc:identifier.uri","download_url":null,"download_label":null,"download_source":null,"access_status":null,"embargo_until":null,"access_note":null},"source_record":{"url":"https://carleton.scholaris.ca/server/oai/request?verb=GetRecord&metadataPrefix=dim&identifier=oai%3Acarleton.scholaris.ca%3A20.500.14718%2F45115","prefix":"dim"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:creator","label":"Author","values":["Sewraj, Kala"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2026-07-22T18:38:09Z"]},{"key":"dc:date.issued","label":"Date","values":["2026"]},{"key":"dc:publisher","label":"Institution","values":["Carleton University"]},{"key":"dc:type","label":"Dc Type","values":["thesis"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Engineering, Building"]},{"key":"thesis:degree_level","label":"Degree Level","values":["Master's"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Master of Applied Science (M.App.Sc.)"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject.lcsh","label":"Dc Subject Lcsh","values":["Buildings--Environmental","Buildings--Repair and construction"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language.iso","label":"Language (ISO)","values":["en"]},{"key":"dc:rights","label":"Dc Rights","values":["Copyright © 2025 the author(s). Theses may be used for non-commercial research, educational, or related academic purposes only. Such uses include personal study, distribution to students, research and scholarship. Theses may only be shared by linking to the Carleton University Institutional Repository and no part may be copied without proper attribution to the author; no part may be used for commercial purposes directly or indirectly via a for-profit platform; no adaptation or derivative works are permitted without consent from the copyright owner."]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.doi","label":"DOI","values":["10.22215/etd/2026-16958"]},{"key":"dc:identifier.uri","label":"Identifier URI","values":["https://hdl.handle.net/20.500.14718/45115"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["Indoor environmental quality (IEQ) critically affects health and comfort, yet limited research has examined IEQ in low-income housing (LIH), which often houses more vulnerable populations. This thesis presents findings from an exploratory field investigation of 18 LIH units, combining multi-season monitoring, monthly surveys, walkthroughs, and semi-structured interviews. Sensors measured temperature, relative humidity, CO₂, PM₂.₅, and TVOCs, which were evaluated using guideline-based thresholds. Correlations and logistic regression assessed alignment between measured conditions and occupant-reported experiences. Thermal conditions were generally acceptable but showed weak alignment with occupant-reported thermal sensations. CO₂ and PM₂.₅ levels were typically within range, while TVOC concentrations varied. Low humidity was a persistent winter issue. Visual comfort was influenced by daylight, lighting distribution, and colour. Higher outdoor noise was associated with lower overall comfort, higher stress, and poorer sleep quality. Interviews highlighted non-IEQ safety and maintenance concerns. Findings informed low-cost, targeted strategies to improve comfort in LIH."]},{"key":"dc:title","label":"Title","values":["Indoor Environmental Quality in Low-Income Housing: An Exploratory Field Study of Comfort in Ottawa"]},{"key":"local:lac.licence","label":"Local Lac Licence","values":["true"]},{"key":"others:access_status","label":"Others Access Status","values":["open.access"]}]}],"canonical_facts":{"dc:creator":["Sewraj, Kala"],"dc:date.accessioned":["2026-07-22T18:38:09Z"],"dc:date.issued":["2026"],"dc:description.abstract":["Indoor environmental quality (IEQ) critically affects health and comfort, yet limited research has examined IEQ in low-income housing (LIH), which often houses more vulnerable populations. This thesis presents findings from an exploratory field investigation of 18 LIH units, combining multi-season monitoring, monthly surveys, walkthroughs, and semi-structured interviews. Sensors measured temperature, relative humidity, CO₂, PM₂.₅, and TVOCs, which were evaluated using guideline-based thresholds. Correlations and logistic regression assessed alignment between measured conditions and occupant-reported experiences. Thermal conditions were generally acceptable but showed weak alignment with occupant-reported thermal sensations. CO₂ and PM₂.₅ levels were typically within range, while TVOC concentrations varied. Low humidity was a persistent winter issue. Visual comfort was influenced by daylight, lighting distribution, and colour. Higher outdoor noise was associated with lower overall comfort, higher stress, and poorer sleep quality. Interviews highlighted non-IEQ safety and maintenance concerns. Findings informed low-cost, targeted strategies to improve comfort in LIH."],"dc:identifier.doi":["10.22215/etd/2026-16958"],"dc:identifier.uri":["https://hdl.handle.net/20.500.14718/45115"],"dc:language.iso":["en"],"dc:publisher":["Carleton University"],"dc:rights":["Copyright © 2025 the author(s). Theses may be used for non-commercial research, educational, or related academic purposes only. Such uses include personal study, distribution to students, research and scholarship. Theses may only be shared by linking to the Carleton University Institutional Repository and no part may be copied without proper attribution to the author; no part may be used for commercial purposes directly or indirectly via a for-profit platform; no adaptation or derivative works are permitted without consent from the copyright owner."],"dc:subject.lcsh":["Buildings--Environmental","Buildings--Repair and construction"],"dc:title":["Indoor Environmental Quality in Low-Income Housing: An Exploratory Field Study of Comfort in Ottawa"],"dc:type":["thesis"],"local:lac.licence":["true"],"others:access_status":["open.access"],"thesis:degree_discipline":["Engineering, Building"],"thesis:degree_level":["Master's"],"thesis:degree_name":["Master of Applied Science (M.App.Sc.)"]},"updated_at":"2026-11-19T07:07:19Z"}