{"id":{"repo_id":"carleton","oai_identifier":"oai:carleton.scholaris.ca:20.500.14718/45118"},"canonical_url":"https://search.ndltd.org/etd/carleton/oai:carleton.scholaris.ca:20.500.14718/45118","repository":{"repo_id":"carleton","name":"Carleton University","base_url":"https://carleton.scholaris.ca/server/oai/request"},"display":{"title":"Off-Grid Solar Utilization and Optimization Study for a Low Energy Residential Building in a Cold Climate","abstract":"Fossil fuel combustion is prevalent in Canadian buildings contributing to global warming. This study used building performance simulation to assess four emissions-free mechanical system concepts focused on eliminating fossil fuels from an off-grid residential building in a cold climate. Building loads are currently met using a combination of renewable and propane technologies. Electricity and propane use in a base building TRNSYS energy model were calibrated and validated to ASHRAE Guideline 14 criteria. The selected concept utilized a photovoltaic-based dual-tank thermal energy storage system with a heat pump and auxiliary electric boiler. A parametric study and three system criteria identified systems capable of meeting building energy loads. The most economical system had a 30 kW photovoltaic array, 77 kWh battery energy storage and, 0.3 m3 diurnal and 40 m3 seasonal thermal energy storages. This system met all building energy requirements and eliminated fossil fuels from the building energy mixture.","abstract_html":"Fossil fuel combustion is prevalent in Canadian buildings contributing to global warming. This study used building performance simulation to assess four emissions-free mechanical system concepts focused on eliminating fossil fuels from an off-grid residential building in a cold climate. Building loads are currently met using a combination of renewable and propane technologies. Electricity and propane use in a base building TRNSYS energy model were calibrated and validated to ASHRAE Guideline 14 criteria. The selected concept utilized a photovoltaic-based dual-tank thermal energy storage system with a heat pump and auxiliary electric boiler. A parametric study and three system criteria identified systems capable of meeting building energy loads. The most economical system had a 30 kW photovoltaic array, 77 kWh battery energy storage and, 0.3 m3 diurnal and 40 m3 seasonal thermal energy storages. This system met all building energy requirements and eliminated fossil fuels from the building energy mixture.","abstract_has_math":false,"creators":["Domsy, Matthew Richard"],"institution":"Carleton University","degree_name":"Master of Applied Science (M.App.Sc.)","degree_level":"Master's","degree_discipline":"Engineering, Mechanical","degree_department":null,"school":null,"contributors":[],"advisors":[],"committee_chairs":[],"committee_members":[],"year":2026,"date_issued":"2026","date_published":"2026","updated_at":"2026-11-19T07:13:35Z","subjects":["Mechanical engineering","Force and energy"],"languages":["en"],"rights":["Copyright © 2026 the author(s). Theses may be used for non-commercial research, educational, or related academic purposes only. Such uses include personal study, distribution to students, research and scholarship. Theses may only be shared by linking to the Carleton University Institutional Repository and no part may be copied without proper attribution to the author; no part may be used for commercial purposes directly or indirectly via a for-profit platform; no adaptation or derivative works are permitted without consent from the copyright owner."],"rights_urls":[],"identifier_entries":[{"key":"dc:identifier.uri","label":"Identifier URI","values":["https://hdl.handle.net/20.500.14718/45118"],"render_values":[{"text":"https://hdl.handle.net/20.500.14718/45118","href":"https://hdl.handle.net/20.500.14718/45118","code":true}]}],"person_identifier_entries":[]},"links":{"outbound_url":"https://doi.org/10.22215/etd/2026-16961","outbound_label":"DOI","outbound_source":"dc:identifier.doi","record_url":"https://doi.org/10.22215/etd/2026-16961","record_label":"Repository record","record_kind":"doi","record_source":"dc:identifier.doi","access_status":null,"embargo_until":null,"access_note":null},"oai_pmh_record":{"url":"https://union.ndltd.org/oai-pmh/?verb=GetRecord&metadataPrefix=oai_dc&identifier=oai%3Aunion.ndltd.org%3Arepo%3Acarleton%3Aoai%3Acarleton.scholaris.ca%3A20.500.14718%2F45118","prefix":"oai_dc"},"source_record":{"url":"https://carleton.scholaris.ca/server/oai/request?verb=GetRecord&metadataPrefix=dim&identifier=oai%3Acarleton.scholaris.ca%3A20.500.14718%2F45118","prefix":"dim"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:creator","label":"Author","values":["Domsy, Matthew Richard"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2026-07-22T18:38:14Z"]},{"key":"dc:date.issued","label":"Date","values":["2026"]},{"key":"dc:publisher","label":"Institution","values":["Carleton University"]},{"key":"dc:type","label":"Dc Type","values":["thesis"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Engineering, Mechanical"]},{"key":"thesis:degree_level","label":"Degree Level","values":["Master's"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Master of Applied Science (M.App.Sc.)"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject.lcsh","label":"Dc Subject Lcsh","values":["Mechanical engineering","Force and energy"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language.iso","label":"Language (ISO)","values":["en"]},{"key":"dc:rights","label":"Dc Rights","values":["Copyright © 2026 the author(s). Theses may be used for non-commercial research, educational, or related academic purposes only. Such uses include personal study, distribution to students, research and scholarship. Theses may only be shared by linking to the Carleton University Institutional Repository and no part may be copied without proper attribution to the author; no part may be used for commercial purposes directly or indirectly via a for-profit platform; no adaptation or derivative works are permitted without consent from the copyright owner."]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.doi","label":"DOI","values":["10.22215/etd/2026-16961"]},{"key":"dc:identifier.uri","label":"Identifier URI","values":["https://hdl.handle.net/20.500.14718/45118"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["Fossil fuel combustion is prevalent in Canadian buildings contributing to global warming. This study used building performance simulation to assess four emissions-free mechanical system concepts focused on eliminating fossil fuels from an off-grid residential building in a cold climate. Building loads are currently met using a combination of renewable and propane technologies. Electricity and propane use in a base building TRNSYS energy model were calibrated and validated to ASHRAE Guideline 14 criteria. The selected concept utilized a photovoltaic-based dual-tank thermal energy storage system with a heat pump and auxiliary electric boiler. A parametric study and three system criteria identified systems capable of meeting building energy loads. The most economical system had a 30 kW photovoltaic array, 77 kWh battery energy storage and, 0.3 m3 diurnal and 40 m3 seasonal thermal energy storages. This system met all building energy requirements and eliminated fossil fuels from the building energy mixture."]},{"key":"dc:title","label":"Title","values":["Off-Grid Solar Utilization and Optimization Study for a Low Energy Residential Building in a Cold Climate"]},{"key":"local:lac.licence","label":"Local Lac Licence","values":["true"]},{"key":"others:access_status","label":"Others Access Status","values":["open.access"]}]}],"canonical_facts":{"dc:creator":["Domsy, Matthew Richard"],"dc:date.accessioned":["2026-07-22T18:38:14Z"],"dc:date.issued":["2026"],"dc:description.abstract":["Fossil fuel combustion is prevalent in Canadian buildings contributing to global warming. This study used building performance simulation to assess four emissions-free mechanical system concepts focused on eliminating fossil fuels from an off-grid residential building in a cold climate. Building loads are currently met using a combination of renewable and propane technologies. Electricity and propane use in a base building TRNSYS energy model were calibrated and validated to ASHRAE Guideline 14 criteria. The selected concept utilized a photovoltaic-based dual-tank thermal energy storage system with a heat pump and auxiliary electric boiler. A parametric study and three system criteria identified systems capable of meeting building energy loads. The most economical system had a 30 kW photovoltaic array, 77 kWh battery energy storage and, 0.3 m3 diurnal and 40 m3 seasonal thermal energy storages. This system met all building energy requirements and eliminated fossil fuels from the building energy mixture."],"dc:identifier.doi":["10.22215/etd/2026-16961"],"dc:identifier.uri":["https://hdl.handle.net/20.500.14718/45118"],"dc:language.iso":["en"],"dc:publisher":["Carleton University"],"dc:rights":["Copyright © 2026 the author(s). Theses may be used for non-commercial research, educational, or related academic purposes only. Such uses include personal study, distribution to students, research and scholarship. Theses may only be shared by linking to the Carleton University Institutional Repository and no part may be copied without proper attribution to the author; no part may be used for commercial purposes directly or indirectly via a for-profit platform; no adaptation or derivative works are permitted without consent from the copyright owner."],"dc:subject.lcsh":["Mechanical engineering","Force and energy"],"dc:title":["Off-Grid Solar Utilization and Optimization Study for a Low Energy Residential Building in a Cold Climate"],"dc:type":["thesis"],"local:lac.licence":["true"],"others:access_status":["open.access"],"thesis:degree_discipline":["Engineering, Mechanical"],"thesis:degree_level":["Master's"],"thesis:degree_name":["Master of Applied Science (M.App.Sc.)"]},"updated_at":"2026-11-19T07:13:35Z"}