{"id":{"repo_id":"carleton","oai_identifier":"oai:carleton.scholaris.ca:20.500.14718/45209"},"canonical_url":"https://search.ndltd.org/etd/carleton/oai:carleton.scholaris.ca:20.500.14718/45209","repository":{"repo_id":"carleton","name":"Carleton University","base_url":"https://carleton.scholaris.ca/server/oai/request"},"display":{"title":"Accelerator Design and Measurements of Proton-Lithium-7 Fusion Cross Section Enhancement","abstract":"Measurements of the fusion cross section enhancement of the 7Li(1H,alpha)4He reaction were made in six different materials, lithium tungstate, lithium manganate, lithium titanate spinel, lithium iron phosphate, crystalline lithium fluoride and crystalline lithium niobate. Using new measurements of the previously reported lithium tungstate as a baseline, a relative enhancement of 1100\\% of the lithium titanate spinel over the lithium tungstate was measured. To extend these measurements further, and address limitations of the accelerator used for those measurements a purpose built accelerator system was designed and constructed to measure cross sections of target materials over an angular range of +/-4.5 degrees, an incident proton energy range of 50 to 100 keV, and a beam current of more than 1 mA. Experimentally identified limitations on the high voltage operation of PEEK and limitations on plasma source operation are described.","abstract_html":"Measurements of the fusion cross section enhancement of the 7Li(1H,alpha)4He reaction were made in six different materials, lithium tungstate, lithium manganate, lithium titanate spinel, lithium iron phosphate, crystalline lithium fluoride and crystalline lithium niobate. Using new measurements of the previously reported lithium tungstate as a baseline, a relative enhancement of 1100\\% of the lithium titanate spinel over the lithium tungstate was measured. To extend these measurements further, and address limitations of the accelerator used for those measurements a purpose built accelerator system was designed and constructed to measure cross sections of target materials over an angular range of +/-4.5 degrees, an incident proton energy range of 50 to 100 keV, and a beam current of more than 1 mA. Experimentally identified limitations on the high voltage operation of PEEK and limitations on plasma source operation are described.","abstract_has_math":false,"creators":["English, Aaron Alexander"],"institution":"Carleton University","degree_name":"Doctor of Philosophy (Ph.D.)","degree_level":"Doctoral","degree_discipline":"Engineering, Electrical and Computer","degree_department":null,"school":null,"contributors":[],"advisors":[],"committee_chairs":[],"committee_members":[],"year":2026,"date_issued":"2026","date_published":"2026","updated_at":"2026-11-19T06:54:14Z","subjects":["Nuclear engineering","Nuclear physics","Force and energy"],"languages":["en"],"rights":["Copyright © 2026 the author(s). Theses may be used for non-commercial research, educational, or related academic purposes only. Such uses include personal study, distribution to students, research and scholarship. Theses may only be shared by linking to the Carleton University Institutional Repository and no part may be copied without proper attribution to the author; no part may be used for commercial purposes directly or indirectly via a for-profit platform; no adaptation or derivative works are permitted without consent from the copyright owner."],"rights_urls":[],"identifier_entries":[{"key":"dc:identifier.doi","label":"DOI","values":["10.22215/etd/2026-17052"],"render_values":[{"text":"10.22215/etd/2026-17052","href":"https://doi.org/10.22215/etd/2026-17052","code":true}]}],"person_identifier_entries":[]},"links":{"outbound_url":"https://hdl.handle.net/20.500.14718/45209","outbound_label":"Handle","outbound_source":"dc:identifier.uri","record_url":"https://hdl.handle.net/20.500.14718/45209","record_label":"Repository record","record_kind":"handle","record_source":"dc:identifier.uri","download_url":null,"download_label":null,"download_source":null,"access_status":null,"embargo_until":null,"access_note":null},"source_record":{"url":"https://carleton.scholaris.ca/server/oai/request?verb=GetRecord&metadataPrefix=dim&identifier=oai%3Acarleton.scholaris.ca%3A20.500.14718%2F45209","prefix":"dim"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:creator","label":"Author","values":["English, Aaron Alexander"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2026-07-22T18:50:40Z"]},{"key":"dc:date.issued","label":"Date","values":["2026"]},{"key":"dc:publisher","label":"Institution","values":["Carleton University"]},{"key":"dc:type","label":"Dc Type","values":["thesis"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Engineering, Electrical and Computer"]},{"key":"thesis:degree_level","label":"Degree Level","values":["Doctoral"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Doctor of Philosophy (Ph.D.)"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject.lcsh","label":"Dc Subject Lcsh","values":["Nuclear engineering","Nuclear physics","Force and energy"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language.iso","label":"Language (ISO)","values":["en"]},{"key":"dc:rights","label":"Dc Rights","values":["Copyright © 2026 the author(s). Theses may be used for non-commercial research, educational, or related academic purposes only. Such uses include personal study, distribution to students, research and scholarship. Theses may only be shared by linking to the Carleton University Institutional Repository and no part may be copied without proper attribution to the author; no part may be used for commercial purposes directly or indirectly via a for-profit platform; no adaptation or derivative works are permitted without consent from the copyright owner."]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.doi","label":"DOI","values":["10.22215/etd/2026-17052"]},{"key":"dc:identifier.uri","label":"Identifier URI","values":["https://hdl.handle.net/20.500.14718/45209"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["Measurements of the fusion cross section enhancement of the 7Li(1H,alpha)4He reaction were made in six different materials, lithium tungstate, lithium manganate, lithium titanate spinel, lithium iron phosphate, crystalline lithium fluoride and crystalline lithium niobate. Using new measurements of the previously reported lithium tungstate as a baseline, a relative enhancement of 1100\\% of the lithium titanate spinel over the lithium tungstate was measured. To extend these measurements further, and address limitations of the accelerator used for those measurements a purpose built accelerator system was designed and constructed to measure cross sections of target materials over an angular range of +/-4.5 degrees, an incident proton energy range of 50 to 100 keV, and a beam current of more than 1 mA. Experimentally identified limitations on the high voltage operation of PEEK and limitations on plasma source operation are described."]},{"key":"dc:title","label":"Title","values":["Accelerator Design and Measurements of Proton-Lithium-7 Fusion Cross Section Enhancement"]},{"key":"local:lac.licence","label":"Local Lac Licence","values":["true"]},{"key":"others:access_status","label":"Others Access Status","values":["open.access"]}]}],"canonical_facts":{"dc:creator":["English, Aaron Alexander"],"dc:date.accessioned":["2026-07-22T18:50:40Z"],"dc:date.issued":["2026"],"dc:description.abstract":["Measurements of the fusion cross section enhancement of the 7Li(1H,alpha)4He reaction were made in six different materials, lithium tungstate, lithium manganate, lithium titanate spinel, lithium iron phosphate, crystalline lithium fluoride and crystalline lithium niobate. Using new measurements of the previously reported lithium tungstate as a baseline, a relative enhancement of 1100\\% of the lithium titanate spinel over the lithium tungstate was measured. To extend these measurements further, and address limitations of the accelerator used for those measurements a purpose built accelerator system was designed and constructed to measure cross sections of target materials over an angular range of +/-4.5 degrees, an incident proton energy range of 50 to 100 keV, and a beam current of more than 1 mA. Experimentally identified limitations on the high voltage operation of PEEK and limitations on plasma source operation are described."],"dc:identifier.doi":["10.22215/etd/2026-17052"],"dc:identifier.uri":["https://hdl.handle.net/20.500.14718/45209"],"dc:language.iso":["en"],"dc:publisher":["Carleton University"],"dc:rights":["Copyright © 2026 the author(s). Theses may be used for non-commercial research, educational, or related academic purposes only. Such uses include personal study, distribution to students, research and scholarship. Theses may only be shared by linking to the Carleton University Institutional Repository and no part may be copied without proper attribution to the author; no part may be used for commercial purposes directly or indirectly via a for-profit platform; no adaptation or derivative works are permitted without consent from the copyright owner."],"dc:subject.lcsh":["Nuclear engineering","Nuclear physics","Force and energy"],"dc:title":["Accelerator Design and Measurements of Proton-Lithium-7 Fusion Cross Section Enhancement"],"dc:type":["thesis"],"local:lac.licence":["true"],"others:access_status":["open.access"],"thesis:degree_discipline":["Engineering, Electrical and Computer"],"thesis:degree_level":["Doctoral"],"thesis:degree_name":["Doctor of Philosophy (Ph.D.)"]},"updated_at":"2026-11-19T06:54:14Z"}