{"id":{"repo_id":"carleton","oai_identifier":"oai:carleton.scholaris.ca:20.500.14718/45244"},"canonical_url":"https://search.ndltd.org/etd/carleton/oai:carleton.scholaris.ca:20.500.14718/45244","repository":{"repo_id":"carleton","name":"Carleton University","base_url":"https://carleton.scholaris.ca/server/oai/request"},"display":{"title":"Effects of Wall Characteristics and Weather Conditions on Air Cavity Flow Rates and Hygrothermal Performance","abstract":"Moisture infiltration in building walls can compromise structural integrity and cause adverse health effects for occupants. A common strategy to remove moisture from the wall is with a gap between the cladding and the inside of the wall. This air gap can remove moisture, but it can worsen thermal performance. The goal of this thesis was to improve hygrothermal modelling of air cavities to build more resilient and energy-efficient buildings. This was done by designing and constructing six in-situ test assemblies with different wall characteristics. An indoor test panel was constructed to induce airflow using fans to evaluate air change rate measurement techniques. The data from the in-situ testing was analysed and conclusions were drawn about moisture and thermal performance. The indoor test panel allowed for the validation of a Computational Fluid Dynamics model. The model results and in-situ data were used to determine correlations between pressure and velocity.","abstract_html":"Moisture infiltration in building walls can compromise structural integrity and cause adverse health effects for occupants. A common strategy to remove moisture from the wall is with a gap between the cladding and the inside of the wall. This air gap can remove moisture, but it can worsen thermal performance. The goal of this thesis was to improve hygrothermal modelling of air cavities to build more resilient and energy-efficient buildings. This was done by designing and constructing six in-situ test assemblies with different wall characteristics. An indoor test panel was constructed to induce airflow using fans to evaluate air change rate measurement techniques. The data from the in-situ testing was analysed and conclusions were drawn about moisture and thermal performance. The indoor test panel allowed for the validation of a Computational Fluid Dynamics model. The model results and in-situ data were used to determine correlations between pressure and velocity.","abstract_has_math":false,"creators":["Missaghian, Roya Celeste"],"institution":"Carleton University","degree_name":"Master of Applied Science (M.App.Sc.)","degree_level":"Master's","degree_discipline":"Engineering, Sustainable Energy","degree_department":null,"school":null,"contributors":[],"advisors":[],"committee_chairs":[],"committee_members":[],"year":2026,"date_issued":"2026","date_published":"2026","updated_at":"2026-11-19T07:08:25Z","subjects":["Mechanical engineering"],"languages":["en"],"rights":["Copyright © 2026 the author(s). Theses may be used for non-commercial research, educational, or related academic purposes only. Such uses include personal study, distribution to students, research and scholarship. Theses may only be shared by linking to the Carleton University Institutional Repository and no part may be copied without proper attribution to the author; no part may be used for commercial purposes directly or indirectly via a for-profit platform; no adaptation or derivative works are permitted without consent from the copyright owner."],"rights_urls":[],"identifier_entries":[{"key":"dc:identifier.doi","label":"DOI","values":["10.22215/etd/2026-17087"],"render_values":[{"text":"10.22215/etd/2026-17087","href":"https://doi.org/10.22215/etd/2026-17087","code":true}]}],"person_identifier_entries":[]},"links":{"outbound_url":"https://hdl.handle.net/20.500.14718/45244","outbound_label":"Handle","outbound_source":"dc:identifier.uri","record_url":"https://hdl.handle.net/20.500.14718/45244","record_label":"Repository record","record_kind":"handle","record_source":"dc:identifier.uri","download_url":null,"download_label":null,"download_source":null,"access_status":null,"embargo_until":null,"access_note":null},"source_record":{"url":"https://carleton.scholaris.ca/server/oai/request?verb=GetRecord&metadataPrefix=dim&identifier=oai%3Acarleton.scholaris.ca%3A20.500.14718%2F45244","prefix":"dim"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:creator","label":"Author","values":["Missaghian, Roya Celeste"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2026-07-22T18:51:42Z"]},{"key":"dc:date.issued","label":"Date","values":["2026"]},{"key":"dc:publisher","label":"Institution","values":["Carleton University"]},{"key":"dc:type","label":"Dc Type","values":["thesis"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Engineering, Sustainable Energy"]},{"key":"thesis:degree_level","label":"Degree Level","values":["Master's"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Master of Applied Science (M.App.Sc.)"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject.lcsh","label":"Dc Subject Lcsh","values":["Mechanical engineering"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language.iso","label":"Language (ISO)","values":["en"]},{"key":"dc:rights","label":"Dc Rights","values":["Copyright © 2026 the author(s). Theses may be used for non-commercial research, educational, or related academic purposes only. Such uses include personal study, distribution to students, research and scholarship. Theses may only be shared by linking to the Carleton University Institutional Repository and no part may be copied without proper attribution to the author; no part may be used for commercial purposes directly or indirectly via a for-profit platform; no adaptation or derivative works are permitted without consent from the copyright owner."]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.doi","label":"DOI","values":["10.22215/etd/2026-17087"]},{"key":"dc:identifier.uri","label":"Identifier URI","values":["https://hdl.handle.net/20.500.14718/45244"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["Moisture infiltration in building walls can compromise structural integrity and cause adverse health effects for occupants. A common strategy to remove moisture from the wall is with a gap between the cladding and the inside of the wall. This air gap can remove moisture, but it can worsen thermal performance. The goal of this thesis was to improve hygrothermal modelling of air cavities to build more resilient and energy-efficient buildings. This was done by designing and constructing six in-situ test assemblies with different wall characteristics. An indoor test panel was constructed to induce airflow using fans to evaluate air change rate measurement techniques. The data from the in-situ testing was analysed and conclusions were drawn about moisture and thermal performance. The indoor test panel allowed for the validation of a Computational Fluid Dynamics model. The model results and in-situ data were used to determine correlations between pressure and velocity."]},{"key":"dc:title","label":"Title","values":["Effects of Wall Characteristics and Weather Conditions on Air Cavity Flow Rates and Hygrothermal Performance"]},{"key":"local:lac.licence","label":"Local Lac Licence","values":["true"]},{"key":"others:access_status","label":"Others Access Status","values":["open.access"]}]}],"canonical_facts":{"dc:creator":["Missaghian, Roya Celeste"],"dc:date.accessioned":["2026-07-22T18:51:42Z"],"dc:date.issued":["2026"],"dc:description.abstract":["Moisture infiltration in building walls can compromise structural integrity and cause adverse health effects for occupants. A common strategy to remove moisture from the wall is with a gap between the cladding and the inside of the wall. This air gap can remove moisture, but it can worsen thermal performance. The goal of this thesis was to improve hygrothermal modelling of air cavities to build more resilient and energy-efficient buildings. This was done by designing and constructing six in-situ test assemblies with different wall characteristics. An indoor test panel was constructed to induce airflow using fans to evaluate air change rate measurement techniques. The data from the in-situ testing was analysed and conclusions were drawn about moisture and thermal performance. The indoor test panel allowed for the validation of a Computational Fluid Dynamics model. The model results and in-situ data were used to determine correlations between pressure and velocity."],"dc:identifier.doi":["10.22215/etd/2026-17087"],"dc:identifier.uri":["https://hdl.handle.net/20.500.14718/45244"],"dc:language.iso":["en"],"dc:publisher":["Carleton University"],"dc:rights":["Copyright © 2026 the author(s). Theses may be used for non-commercial research, educational, or related academic purposes only. Such uses include personal study, distribution to students, research and scholarship. Theses may only be shared by linking to the Carleton University Institutional Repository and no part may be copied without proper attribution to the author; no part may be used for commercial purposes directly or indirectly via a for-profit platform; no adaptation or derivative works are permitted without consent from the copyright owner."],"dc:subject.lcsh":["Mechanical engineering"],"dc:title":["Effects of Wall Characteristics and Weather Conditions on Air Cavity Flow Rates and Hygrothermal Performance"],"dc:type":["thesis"],"local:lac.licence":["true"],"others:access_status":["open.access"],"thesis:degree_discipline":["Engineering, Sustainable Energy"],"thesis:degree_level":["Master's"],"thesis:degree_name":["Master of Applied Science (M.App.Sc.)"]},"updated_at":"2026-11-19T07:08:25Z"}