{"id":{"repo_id":"carleton","oai_identifier":"oai:carleton.scholaris.ca:20.500.14718/45266"},"canonical_url":"https://search.ndltd.org/etd/carleton/oai:carleton.scholaris.ca:20.500.14718/45266","repository":{"repo_id":"carleton","name":"Carleton University","base_url":"https://carleton.scholaris.ca/server/oai/request"},"display":{"title":"Drinking Water Biofilters-impacts of backwashing techniques at full scale","abstract":"Maintaining the efficiency and performance of biofilters requires routine backwashing, an event that may disrupt biofilter health and functionality. This study investigates the impact of backwashing on the performance of microbial biofilters at Britannia and Lemieux Water Treatment Plants. More specifically, the effects of different backwashing approaches, air scouring combined with hydraulic backwash and hydraulic only backwash were evaluated across seasonal variations. Additionally, the influence of chlorinated backwash water on biofilter performance following backwashing events was also assessed. Performance metrics, including floc retention, dissolved organic carbon (DOC) removal, microbial biomass and composition were examined. Air scouring with water achieved more effective cleaning, while the hydraulically backwashed filter demonstrated a higher retention of media-associated floc. The evaluation of the effects of chlorinated backwash water showed no adverse impact on biofilter performance. Additionally, the recovery of microbial biomass to expected levels was found to potentially require a period longer than a season.","abstract_html":"Maintaining the efficiency and performance of biofilters requires routine backwashing, an event that may disrupt biofilter health and functionality. This study investigates the impact of backwashing on the performance of microbial biofilters at Britannia and Lemieux Water Treatment Plants. More specifically, the effects of different backwashing approaches, air scouring combined with hydraulic backwash and hydraulic only backwash were evaluated across seasonal variations. Additionally, the influence of chlorinated backwash water on biofilter performance following backwashing events was also assessed. Performance metrics, including floc retention, dissolved organic carbon (DOC) removal, microbial biomass and composition were examined. Air scouring with water achieved more effective cleaning, while the hydraulically backwashed filter demonstrated a higher retention of media-associated floc. The evaluation of the effects of chlorinated backwash water showed no adverse impact on biofilter performance. Additionally, the recovery of microbial biomass to expected levels was found to potentially require a period longer than a season.","abstract_has_math":false,"creators":["Anim, Issabella"],"institution":"Carleton University","degree_name":"Master of Applied Science (M.App.Sc.)","degree_level":"Master's","degree_discipline":"Engineering, Environmental","degree_department":null,"school":null,"contributors":[],"advisors":[],"committee_chairs":[],"committee_members":[],"year":2026,"date_issued":"2026","date_published":"2026","updated_at":"2026-11-19T06:55:28Z","subjects":["Environmental engineering","Environmental sciences"],"languages":["en"],"rights":["Copyright © 2026 the author(s). Theses may be used for non-commercial research, educational, or related academic purposes only. Such uses include personal study, distribution to students, research and scholarship. Theses may only be shared by linking to the Carleton University Institutional Repository and no part may be copied without proper attribution to the author; no part may be used for commercial purposes directly or indirectly via a for-profit platform; no adaptation or derivative works are permitted without consent from the copyright owner."],"rights_urls":[],"identifier_entries":[{"key":"dc:identifier.doi","label":"DOI","values":["10.22215/etd/2026-17109"],"render_values":[{"text":"10.22215/etd/2026-17109","href":"https://doi.org/10.22215/etd/2026-17109","code":true}]}],"person_identifier_entries":[]},"links":{"outbound_url":"https://hdl.handle.net/20.500.14718/45266","outbound_label":"Handle","outbound_source":"dc:identifier.uri","record_url":"https://hdl.handle.net/20.500.14718/45266","record_label":"Repository record","record_kind":"handle","record_source":"dc:identifier.uri","download_url":null,"download_label":null,"download_source":null,"access_status":null,"embargo_until":null,"access_note":null},"source_record":{"url":"https://carleton.scholaris.ca/server/oai/request?verb=GetRecord&metadataPrefix=dim&identifier=oai%3Acarleton.scholaris.ca%3A20.500.14718%2F45266","prefix":"dim"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:creator","label":"Author","values":["Anim, Issabella"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2026-07-22T18:52:22Z"]},{"key":"dc:date.issued","label":"Date","values":["2026"]},{"key":"dc:publisher","label":"Institution","values":["Carleton University"]},{"key":"dc:type","label":"Dc Type","values":["thesis"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Engineering, Environmental"]},{"key":"thesis:degree_level","label":"Degree Level","values":["Master's"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Master of Applied Science (M.App.Sc.)"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject.lcsh","label":"Dc Subject Lcsh","values":["Environmental engineering","Environmental sciences"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language.iso","label":"Language (ISO)","values":["en"]},{"key":"dc:rights","label":"Dc Rights","values":["Copyright © 2026 the author(s). Theses may be used for non-commercial research, educational, or related academic purposes only. Such uses include personal study, distribution to students, research and scholarship. Theses may only be shared by linking to the Carleton University Institutional Repository and no part may be copied without proper attribution to the author; no part may be used for commercial purposes directly or indirectly via a for-profit platform; no adaptation or derivative works are permitted without consent from the copyright owner."]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.doi","label":"DOI","values":["10.22215/etd/2026-17109"]},{"key":"dc:identifier.uri","label":"Identifier URI","values":["https://hdl.handle.net/20.500.14718/45266"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["Maintaining the efficiency and performance of biofilters requires routine backwashing, an event that may disrupt biofilter health and functionality. This study investigates the impact of backwashing on the performance of microbial biofilters at Britannia and Lemieux Water Treatment Plants. More specifically, the effects of different backwashing approaches, air scouring combined with hydraulic backwash and hydraulic only backwash were evaluated across seasonal variations. Additionally, the influence of chlorinated backwash water on biofilter performance following backwashing events was also assessed. Performance metrics, including floc retention, dissolved organic carbon (DOC) removal, microbial biomass and composition were examined. Air scouring with water achieved more effective cleaning, while the hydraulically backwashed filter demonstrated a higher retention of media-associated floc. The evaluation of the effects of chlorinated backwash water showed no adverse impact on biofilter performance. Additionally, the recovery of microbial biomass to expected levels was found to potentially require a period longer than a season."]},{"key":"dc:title","label":"Title","values":["Drinking Water Biofilters-impacts of backwashing techniques at full scale"]},{"key":"local:lac.licence","label":"Local Lac Licence","values":["true"]},{"key":"others:access_status","label":"Others Access Status","values":["open.access"]}]}],"canonical_facts":{"dc:creator":["Anim, Issabella"],"dc:date.accessioned":["2026-07-22T18:52:22Z"],"dc:date.issued":["2026"],"dc:description.abstract":["Maintaining the efficiency and performance of biofilters requires routine backwashing, an event that may disrupt biofilter health and functionality. This study investigates the impact of backwashing on the performance of microbial biofilters at Britannia and Lemieux Water Treatment Plants. More specifically, the effects of different backwashing approaches, air scouring combined with hydraulic backwash and hydraulic only backwash were evaluated across seasonal variations. Additionally, the influence of chlorinated backwash water on biofilter performance following backwashing events was also assessed. Performance metrics, including floc retention, dissolved organic carbon (DOC) removal, microbial biomass and composition were examined. Air scouring with water achieved more effective cleaning, while the hydraulically backwashed filter demonstrated a higher retention of media-associated floc. The evaluation of the effects of chlorinated backwash water showed no adverse impact on biofilter performance. Additionally, the recovery of microbial biomass to expected levels was found to potentially require a period longer than a season."],"dc:identifier.doi":["10.22215/etd/2026-17109"],"dc:identifier.uri":["https://hdl.handle.net/20.500.14718/45266"],"dc:language.iso":["en"],"dc:publisher":["Carleton University"],"dc:rights":["Copyright © 2026 the author(s). Theses may be used for non-commercial research, educational, or related academic purposes only. Such uses include personal study, distribution to students, research and scholarship. Theses may only be shared by linking to the Carleton University Institutional Repository and no part may be copied without proper attribution to the author; no part may be used for commercial purposes directly or indirectly via a for-profit platform; no adaptation or derivative works are permitted without consent from the copyright owner."],"dc:subject.lcsh":["Environmental engineering","Environmental sciences"],"dc:title":["Drinking Water Biofilters-impacts of backwashing techniques at full scale"],"dc:type":["thesis"],"local:lac.licence":["true"],"others:access_status":["open.access"],"thesis:degree_discipline":["Engineering, Environmental"],"thesis:degree_level":["Master's"],"thesis:degree_name":["Master of Applied Science (M.App.Sc.)"]},"updated_at":"2026-11-19T06:55:28Z"}