{"id":{"repo_id":"carleton","oai_identifier":"oai:carleton.scholaris.ca:20.500.14718/45268"},"canonical_url":"https://search.ndltd.org/etd/carleton/oai:carleton.scholaris.ca:20.500.14718/45268","repository":{"repo_id":"carleton","name":"Carleton University","base_url":"https://carleton.scholaris.ca/server/oai/request"},"display":{"title":"Signal Modelling and Physiological Parameter Extraction for a Multisensor Handheld Cardiac Monitoring Device","abstract":"This thesis investigates signal acquisition and physiological parameter extraction in a compact multisensor handheld cardiac monitor, integrating electrocardiography (ECG) and photoplethysmography (PPG). The use of dry-contact ECG leads is assessed for its impact on signal quality. An electrode spacing of 7mm is recommended to minimize the number of missed beats. Although reduced inter-electrode spacing decreases QRS amplitude, a robust Pan–Tompkins beat detection algorithm can still detect beats for the calculation of Heart Rate and Heart Rate Variability under various noise conditions. A two-Gaussian modeling framework is proposed with iterative Gaussian decomposition for single-cycle PPG morphology analysis. The method enables robust extraction of systolic and diastolic features, including dicrotic notch timing and augmentation index, for simulated Sand clinical data. The model is evaluated in longitudinal PPG analysis, enabling beat-to-beat morphological tracking. Together, these contributions establish an integrated, signal-aware framework to assist in remote cardiac monitoring systems.","abstract_html":"This thesis investigates signal acquisition and physiological parameter extraction in a compact multisensor handheld cardiac monitor, integrating electrocardiography (ECG) and photoplethysmography (PPG). The use of dry-contact ECG leads is assessed for its impact on signal quality. An electrode spacing of 7mm is recommended to minimize the number of missed beats. Although reduced inter-electrode spacing decreases QRS amplitude, a robust Pan–Tompkins beat detection algorithm can still detect beats for the calculation of Heart Rate and Heart Rate Variability under various noise conditions. A two-Gaussian modeling framework is proposed with iterative Gaussian decomposition for single-cycle PPG morphology analysis. The method enables robust extraction of systolic and diastolic features, including dicrotic notch timing and augmentation index, for simulated Sand clinical data. The model is evaluated in longitudinal PPG analysis, enabling beat-to-beat morphological tracking. Together, these contributions establish an integrated, signal-aware framework to assist in remote cardiac monitoring systems.","abstract_has_math":false,"creators":["Forster, Phillippe"],"institution":"Carleton University","degree_name":"Master of Applied Science (M.App.Sc.)","degree_level":"Master's","degree_discipline":"Engineering, Electrical and Computer","degree_department":null,"school":null,"contributors":[],"advisors":[],"committee_chairs":[],"committee_members":[],"year":2026,"date_issued":"2026","date_published":"2026","updated_at":"2026-11-19T07:13:56Z","subjects":["Electrical engineering","Biomedical engineering"],"languages":["en"],"rights":["Copyright © 2026 the author(s). Theses may be used for non-commercial research, educational, or related academic purposes only. Such uses include personal study, distribution to students, research and scholarship. Theses may only be shared by linking to the Carleton University Institutional Repository and no part may be copied without proper attribution to the author; no part may be used for commercial purposes directly or indirectly via a for-profit platform; no adaptation or derivative works are permitted without consent from the copyright owner."],"rights_urls":[],"identifier_entries":[{"key":"dc:identifier.doi","label":"DOI","values":["10.22215/etd/2026-17111"],"render_values":[{"text":"10.22215/etd/2026-17111","href":"https://doi.org/10.22215/etd/2026-17111","code":true}]}],"person_identifier_entries":[]},"links":{"outbound_url":"https://hdl.handle.net/20.500.14718/45268","outbound_label":"Handle","outbound_source":"dc:identifier.uri","record_url":"https://hdl.handle.net/20.500.14718/45268","record_label":"Repository record","record_kind":"handle","record_source":"dc:identifier.uri","download_url":null,"download_label":null,"download_source":null,"access_status":null,"embargo_until":null,"access_note":null},"source_record":{"url":"https://carleton.scholaris.ca/server/oai/request?verb=GetRecord&metadataPrefix=dim&identifier=oai%3Acarleton.scholaris.ca%3A20.500.14718%2F45268","prefix":"dim"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:creator","label":"Author","values":["Forster, Phillippe"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2026-07-22T18:52:24Z"]},{"key":"dc:date.issued","label":"Date","values":["2026"]},{"key":"dc:publisher","label":"Institution","values":["Carleton University"]},{"key":"dc:type","label":"Dc Type","values":["thesis"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Engineering, Electrical and Computer"]},{"key":"thesis:degree_level","label":"Degree Level","values":["Master's"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Master of Applied Science (M.App.Sc.)"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject.lcsh","label":"Dc Subject Lcsh","values":["Electrical engineering","Biomedical engineering"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language.iso","label":"Language (ISO)","values":["en"]},{"key":"dc:rights","label":"Dc Rights","values":["Copyright © 2026 the author(s). Theses may be used for non-commercial research, educational, or related academic purposes only. Such uses include personal study, distribution to students, research and scholarship. Theses may only be shared by linking to the Carleton University Institutional Repository and no part may be copied without proper attribution to the author; no part may be used for commercial purposes directly or indirectly via a for-profit platform; no adaptation or derivative works are permitted without consent from the copyright owner."]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.doi","label":"DOI","values":["10.22215/etd/2026-17111"]},{"key":"dc:identifier.uri","label":"Identifier URI","values":["https://hdl.handle.net/20.500.14718/45268"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["This thesis investigates signal acquisition and physiological parameter extraction in a compact multisensor handheld cardiac monitor, integrating electrocardiography (ECG) and photoplethysmography (PPG). The use of dry-contact ECG leads is assessed for its impact on signal quality. An electrode spacing of 7mm is recommended to minimize the number of missed beats. Although reduced inter-electrode spacing decreases QRS amplitude, a robust Pan–Tompkins beat detection algorithm can still detect beats for the calculation of Heart Rate and Heart Rate Variability under various noise conditions. A two-Gaussian modeling framework is proposed with iterative Gaussian decomposition for single-cycle PPG morphology analysis. The method enables robust extraction of systolic and diastolic features, including dicrotic notch timing and augmentation index, for simulated Sand clinical data. The model is evaluated in longitudinal PPG analysis, enabling beat-to-beat morphological tracking. Together, these contributions establish an integrated, signal-aware framework to assist in remote cardiac monitoring systems."]},{"key":"dc:title","label":"Title","values":["Signal Modelling and Physiological Parameter Extraction for a Multisensor Handheld Cardiac Monitoring Device"]},{"key":"local:lac.licence","label":"Local Lac Licence","values":["true"]},{"key":"others:access_status","label":"Others Access Status","values":["open.access"]}]}],"canonical_facts":{"dc:creator":["Forster, Phillippe"],"dc:date.accessioned":["2026-07-22T18:52:24Z"],"dc:date.issued":["2026"],"dc:description.abstract":["This thesis investigates signal acquisition and physiological parameter extraction in a compact multisensor handheld cardiac monitor, integrating electrocardiography (ECG) and photoplethysmography (PPG). The use of dry-contact ECG leads is assessed for its impact on signal quality. An electrode spacing of 7mm is recommended to minimize the number of missed beats. Although reduced inter-electrode spacing decreases QRS amplitude, a robust Pan–Tompkins beat detection algorithm can still detect beats for the calculation of Heart Rate and Heart Rate Variability under various noise conditions. A two-Gaussian modeling framework is proposed with iterative Gaussian decomposition for single-cycle PPG morphology analysis. The method enables robust extraction of systolic and diastolic features, including dicrotic notch timing and augmentation index, for simulated Sand clinical data. The model is evaluated in longitudinal PPG analysis, enabling beat-to-beat morphological tracking. Together, these contributions establish an integrated, signal-aware framework to assist in remote cardiac monitoring systems."],"dc:identifier.doi":["10.22215/etd/2026-17111"],"dc:identifier.uri":["https://hdl.handle.net/20.500.14718/45268"],"dc:language.iso":["en"],"dc:publisher":["Carleton University"],"dc:rights":["Copyright © 2026 the author(s). Theses may be used for non-commercial research, educational, or related academic purposes only. Such uses include personal study, distribution to students, research and scholarship. Theses may only be shared by linking to the Carleton University Institutional Repository and no part may be copied without proper attribution to the author; no part may be used for commercial purposes directly or indirectly via a for-profit platform; no adaptation or derivative works are permitted without consent from the copyright owner."],"dc:subject.lcsh":["Electrical engineering","Biomedical engineering"],"dc:title":["Signal Modelling and Physiological Parameter Extraction for a Multisensor Handheld Cardiac Monitoring Device"],"dc:type":["thesis"],"local:lac.licence":["true"],"others:access_status":["open.access"],"thesis:degree_discipline":["Engineering, Electrical and Computer"],"thesis:degree_level":["Master's"],"thesis:degree_name":["Master of Applied Science (M.App.Sc.)"]},"updated_at":"2026-11-19T07:13:56Z"}