{"id":{"repo_id":"clemson","oai_identifier":"oai:open.clemson.edu:all_dissertations-4491"},"canonical_url":"https://search.ndltd.org/etd/clemson/oai:open.clemson.edu:all_dissertations-4491","repository":{"repo_id":"clemson","name":"Clemson University","base_url":"https://open.clemson.edu/do/oai/"},"display":{"title":"Studies on Electrochemical Hydrogen Isotope Separation","abstract":"Graphene-integrated Proton Exchange Membrane (PEM) electrochemical cells have emerged as a novel area of scientific investigation in the realm of hydrogen isotope separation. Chemical Vapor Deposited (CVD) graphene has been especially useful due to its large-scale production capability for scaling-up purposes. The research described in this dissertation explores the role that inadvertent introduction of cations, notably ammonium and copper, during the CVD graphene transfer onto PEM substrates, such as Nafion, might play in affecting hydrogen ion transport and isotope separation in PEM electrochemical cells. An extensive review of existing literature exposed a gap concerning unintentional cation introductions during graphene transfer, and this research posits that observations of apparent isotope separation could be attributable to effects from ammonium or copper cations in the membranes. Central to these studies is the elucidation of the challenges in reproducing optimal H/D selectivities, attributed to methodological inconsistencies. Seeking deeper insights, this study tapped into the capabilities of the Online Electrochemistry Mass Spectrometry (OEMS) system. Rather than relying on comparative studies in separate H and D electrochemical pump cells, the OEMS facilitated time-dependent studies of evolved gases in electrochemical pump cells, allowing for the direct analysis of true isotope separation from gas mixtures. Employing techniques to directly probe H/D separation, this dissertation identifies a minimal impact of graphene on this process. This investigation aligns with other recent works that question established beliefs regarding CVD graphene's pronounced impact on hydrogen isotope separation.","abstract_html":"Graphene-integrated Proton Exchange Membrane (PEM) electrochemical cells have emerged as a novel area of scientific investigation in the realm of hydrogen isotope separation. Chemical Vapor Deposited (CVD) graphene has been especially useful due to its large-scale production capability for scaling-up purposes. The research described in this dissertation explores the role that inadvertent introduction of cations, notably ammonium and copper, during the CVD graphene transfer onto PEM substrates, such as Nafion, might play in affecting hydrogen ion transport and isotope separation in PEM electrochemical cells. An extensive review of existing literature exposed a gap concerning unintentional cation introductions during graphene transfer, and this research posits that observations of apparent isotope separation could be attributable to effects from ammonium or copper cations in the membranes. Central to these studies is the elucidation of the challenges in reproducing optimal H/D selectivities, attributed to methodological inconsistencies. Seeking deeper insights, this study tapped into the capabilities of the Online Electrochemistry Mass Spectrometry (OEMS) system. Rather than relying on comparative studies in separate H and D electrochemical pump cells, the OEMS facilitated time-dependent studies of evolved gases in electrochemical pump cells, allowing for the direct analysis of true isotope separation from gas mixtures. Employing techniques to directly probe H/D separation, this dissertation identifies a minimal impact of graphene on this process. This investigation aligns with other recent works that question established beliefs regarding CVD graphene&#x27;s pronounced impact on hydrogen isotope separation.","abstract_has_math":false,"creators":["Silva, Liyanage Mayura Sankalpa"],"institution":null,"degree_name":"Doctor of Philosophy (PhD)","degree_level":"Dissertation","degree_discipline":"Chemistry","degree_department":null,"school":null,"contributors":["Prof. Stephen Creager","Prof. Ken Marcus","Prof. George Chumanov","Dr. Xin Xiao"],"advisors":[],"committee_chairs":[],"committee_members":[],"year":null,"date_issued":"","date_published":null,"updated_at":"2026-11-19T07:31:19Z","subjects":["Hydrogen Isotope Separation","Proton Exchange Membranes","OEMS","CVD graphene","Nafion","Cation Exchange","Analytical Chemistry","Materials Chemistry"],"languages":[],"rights":[],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"https://open.clemson.edu/all_dissertations/3484","outbound_label":"Repository record","outbound_source":"dc:identifier","record_url":"https://open.clemson.edu/all_dissertations/3484","record_label":"Repository record","record_kind":"record","record_source":"dc:identifier","download_url":null,"download_label":null,"download_source":null,"access_status":null,"embargo_until":null,"access_note":null},"source_record":{"url":"https://open.clemson.edu/do/oai/?verb=GetRecord&metadataPrefix=oai_etdms&identifier=oai%3Aopen.clemson.edu%3Aall_dissertations-4491","prefix":"oai_etdms"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor","label":"Contributor","values":["Prof. Stephen Creager","Prof. Ken Marcus","Prof. George Chumanov","Dr. Xin Xiao"]},{"key":"dc:creator","label":"Author","values":["Silva, Liyanage Mayura Sankalpa"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.available","label":"Dc Date Available","values":["2023-08-23T07:00:00Z"]},{"key":"dc:date.created","label":"Dc Date Created","values":["2023-12-01T08:00:00Z"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Chemistry"]},{"key":"thesis:degree_level","label":"Degree Level","values":["Dissertation"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Doctor of Philosophy (PhD)"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Hydrogen Isotope Separation","Proton Exchange Membranes","OEMS","CVD graphene","Nafion","Cation Exchange","Analytical Chemistry","Materials Chemistry"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier","label":"Identifier","values":["https://open.clemson.edu/all_dissertations/3484"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["Graphene-integrated Proton Exchange Membrane (PEM) electrochemical cells have emerged as a novel area of scientific investigation in the realm of hydrogen isotope separation. Chemical Vapor Deposited (CVD) graphene has been especially useful due to its large-scale production capability for scaling-up purposes. The research described in this dissertation explores the role that inadvertent introduction of cations, notably ammonium and copper, during the CVD graphene transfer onto PEM substrates, such as Nafion, might play in affecting hydrogen ion transport and isotope separation in PEM electrochemical cells. An extensive review of existing literature exposed a gap concerning unintentional cation introductions during graphene transfer, and this research posits that observations of apparent isotope separation could be attributable to effects from ammonium or copper cations in the membranes. Central to these studies is the elucidation of the challenges in reproducing optimal H/D selectivities, attributed to methodological inconsistencies. Seeking deeper insights, this study tapped into the capabilities of the Online Electrochemistry Mass Spectrometry (OEMS) system. Rather than relying on comparative studies in separate H and D electrochemical pump cells, the OEMS facilitated time-dependent studies of evolved gases in electrochemical pump cells, allowing for the direct analysis of true isotope separation from gas mixtures. Employing techniques to directly probe H/D separation, this dissertation identifies a minimal impact of graphene on this process. This investigation aligns with other recent works that question established beliefs regarding CVD graphene's pronounced impact on hydrogen isotope separation."]},{"key":"dc:title","label":"Title","values":["Studies on Electrochemical Hydrogen Isotope Separation"]}]}],"canonical_facts":{"dc:contributor":["Prof. Stephen Creager","Prof. Ken Marcus","Prof. George Chumanov","Dr. Xin Xiao"],"dc:creator":["Silva, Liyanage Mayura Sankalpa"],"dc:date.available":["2023-08-23T07:00:00Z"],"dc:date.created":["2023-12-01T08:00:00Z"],"dc:description.abstract":["Graphene-integrated Proton Exchange Membrane (PEM) electrochemical cells have emerged as a novel area of scientific investigation in the realm of hydrogen isotope separation. Chemical Vapor Deposited (CVD) graphene has been especially useful due to its large-scale production capability for scaling-up purposes. The research described in this dissertation explores the role that inadvertent introduction of cations, notably ammonium and copper, during the CVD graphene transfer onto PEM substrates, such as Nafion, might play in affecting hydrogen ion transport and isotope separation in PEM electrochemical cells. An extensive review of existing literature exposed a gap concerning unintentional cation introductions during graphene transfer, and this research posits that observations of apparent isotope separation could be attributable to effects from ammonium or copper cations in the membranes. Central to these studies is the elucidation of the challenges in reproducing optimal H/D selectivities, attributed to methodological inconsistencies. Seeking deeper insights, this study tapped into the capabilities of the Online Electrochemistry Mass Spectrometry (OEMS) system. Rather than relying on comparative studies in separate H and D electrochemical pump cells, the OEMS facilitated time-dependent studies of evolved gases in electrochemical pump cells, allowing for the direct analysis of true isotope separation from gas mixtures. Employing techniques to directly probe H/D separation, this dissertation identifies a minimal impact of graphene on this process. This investigation aligns with other recent works that question established beliefs regarding CVD graphene's pronounced impact on hydrogen isotope separation."],"dc:identifier":["https://open.clemson.edu/all_dissertations/3484"],"dc:subject":["Hydrogen Isotope Separation","Proton Exchange Membranes","OEMS","CVD graphene","Nafion","Cation Exchange","Analytical Chemistry","Materials Chemistry"],"dc:title":["Studies on Electrochemical Hydrogen Isotope Separation"],"thesis:degree_discipline":["Chemistry"],"thesis:degree_level":["Dissertation"],"thesis:degree_name":["Doctor of Philosophy (PhD)"]},"updated_at":"2026-11-19T07:31:19Z"}