{"id":{"repo_id":"clemson","oai_identifier":"oai:open.clemson.edu:all_theses-2239"},"canonical_url":"https://search.ndltd.org/etd/clemson/oai:open.clemson.edu:all_theses-2239","repository":{"repo_id":"clemson","name":"Clemson University","base_url":"https://open.clemson.edu/do/oai/"},"display":{"title":"Measuring Digital System Latency from Sensing to Actuation at Continuous 1 Millisecond Resolution","abstract":"This thesis describes a new method for measuring the end-to-end latency between sensing and actuation in a digital computing system. Compared to previous work, which generally measures the latency at 16-33 ms intervals or at discrete events separated by hundreds of ms, our new method measures the latency continuously at 1 millisecond resolution. This allows for the observation of variations in latency over sub 1 s periods, instead of relying upon averages of measurements. We have applied our method to two systems, the ?rst using a camera for sensing and an LCD monitor for actuation, and the second using an orientation sensor for sensing and a motor for actuation. Our results show two interesting ?ndings. First, a cyclical variation in latency can be seen based upon the relative rates of the sensor and actuator clocks and bu?er times; for the components we tested the variation was in the range of 15-50 Hz with a magnitude of 10-20 ms. Second, orientation sensor error can look like a variation in latency; for the sensor we tested the variation was in the range of 0.5-1.0 Hz with a magnitude of 20-100 ms. Both of these ?ndings have implications for robotics and virtual reality systems. In particular, it is possible that the variation in apparent latency caused by orientation sensor error may have some relation to 'simulator sickness'.","abstract_html":"This thesis describes a new method for measuring the end-to-end latency between sensing and actuation in a digital computing system. Compared to previous work, which generally measures the latency at 16-33 ms intervals or at discrete events separated by hundreds of ms, our new method measures the latency continuously at 1 millisecond resolution. This allows for the observation of variations in latency over sub 1 s periods, instead of relying upon averages of measurements. We have applied our method to two systems, the ?rst using a camera for sensing and an LCD monitor for actuation, and the second using an orientation sensor for sensing and a motor for actuation. Our results show two interesting ?ndings. First, a cyclical variation in latency can be seen based upon the relative rates of the sensor and actuator clocks and bu?er times; for the components we tested the variation was in the range of 15-50 Hz with a magnitude of 10-20 ms. Second, orientation sensor error can look like a variation in latency; for the sensor we tested the variation was in the range of 0.5-1.0 Hz with a magnitude of 20-100 ms. Both of these ?ndings have implications for robotics and virtual reality systems. In particular, it is possible that the variation in apparent latency caused by orientation sensor error may have some relation to &#x27;simulator sickness&#x27;.","abstract_has_math":false,"creators":["Wu, Weixin"],"institution":null,"degree_name":"Master of Science (MS)","degree_level":"Thesis","degree_discipline":"Electrical and Computer Engineering","degree_department":null,"school":null,"contributors":["Hoover, Adam","Birchfield , Stan","Gowdy , John"],"advisors":[],"committee_chairs":[],"committee_members":[],"year":null,"date_issued":"","date_published":null,"updated_at":"2026-11-19T07:08:14Z","subjects":["Head mount display","High speed camera","Human nausea","Image processing","Latency distribution","System latency","Computer Engineering"],"languages":[],"rights":[],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"https://open.clemson.edu/all_theses/1239","outbound_label":"Repository record","outbound_source":"dc:identifier","record_url":"https://open.clemson.edu/all_theses/1239","record_label":"Repository record","record_kind":"record","record_source":"dc:identifier","download_url":null,"download_label":null,"download_source":null,"access_status":null,"embargo_until":null,"access_note":null},"source_record":{"url":"https://open.clemson.edu/do/oai/?verb=GetRecord&metadataPrefix=oai_etdms&identifier=oai%3Aopen.clemson.edu%3Aall_theses-2239","prefix":"oai_etdms"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor","label":"Contributor","values":["Hoover, Adam","Birchfield , Stan","Gowdy , John"]},{"key":"dc:creator","label":"Author","values":["Wu, Weixin"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.available","label":"Dc Date Available","values":["2015-09-30T07:00:00Z"]},{"key":"dc:date.created","label":"Dc Date Created","values":["2011-12-01T08:00:00Z"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Electrical and Computer Engineering"]},{"key":"thesis:degree_level","label":"Degree Level","values":["Thesis"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Master of Science (MS)"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Head mount display","High speed camera","Human nausea","Image processing","Latency distribution","System latency","Computer Engineering"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier","label":"Identifier","values":["https://open.clemson.edu/all_theses/1239"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["This thesis describes a new method for measuring the end-to-end latency between sensing and actuation in a digital computing system. Compared to previous work, which generally measures the latency at 16-33 ms intervals or at discrete events separated by hundreds of ms, our new method measures the latency continuously at 1 millisecond resolution. This allows for the observation of variations in latency over sub 1 s periods, instead of relying upon averages of measurements. We have applied our method to two systems, the ?rst using a camera for sensing and an LCD monitor for actuation, and the second using an orientation sensor for sensing and a motor for actuation. Our results show two interesting ?ndings. First, a cyclical variation in latency can be seen based upon the relative rates of the sensor and actuator clocks and bu?er times; for the components we tested the variation was in the range of 15-50 Hz with a magnitude of 10-20 ms. Second, orientation sensor error can look like a variation in latency; for the sensor we tested the variation was in the range of 0.5-1.0 Hz with a magnitude of 20-100 ms. Both of these ?ndings have implications for robotics and virtual reality systems. In particular, it is possible that the variation in apparent latency caused by orientation sensor error may have some relation to 'simulator sickness'."]},{"key":"dc:title","label":"Title","values":["Measuring Digital System Latency from Sensing to Actuation at Continuous 1 Millisecond Resolution"]}]}],"canonical_facts":{"dc:contributor":["Hoover, Adam","Birchfield , Stan","Gowdy , John"],"dc:creator":["Wu, Weixin"],"dc:date.available":["2015-09-30T07:00:00Z"],"dc:date.created":["2011-12-01T08:00:00Z"],"dc:description.abstract":["This thesis describes a new method for measuring the end-to-end latency between sensing and actuation in a digital computing system. Compared to previous work, which generally measures the latency at 16-33 ms intervals or at discrete events separated by hundreds of ms, our new method measures the latency continuously at 1 millisecond resolution. This allows for the observation of variations in latency over sub 1 s periods, instead of relying upon averages of measurements. We have applied our method to two systems, the ?rst using a camera for sensing and an LCD monitor for actuation, and the second using an orientation sensor for sensing and a motor for actuation. Our results show two interesting ?ndings. First, a cyclical variation in latency can be seen based upon the relative rates of the sensor and actuator clocks and bu?er times; for the components we tested the variation was in the range of 15-50 Hz with a magnitude of 10-20 ms. Second, orientation sensor error can look like a variation in latency; for the sensor we tested the variation was in the range of 0.5-1.0 Hz with a magnitude of 20-100 ms. Both of these ?ndings have implications for robotics and virtual reality systems. In particular, it is possible that the variation in apparent latency caused by orientation sensor error may have some relation to 'simulator sickness'."],"dc:identifier":["https://open.clemson.edu/all_theses/1239"],"dc:subject":["Head mount display","High speed camera","Human nausea","Image processing","Latency distribution","System latency","Computer Engineering"],"dc:title":["Measuring Digital System Latency from Sensing to Actuation at Continuous 1 Millisecond Resolution"],"thesis:degree_discipline":["Electrical and Computer Engineering"],"thesis:degree_level":["Thesis"],"thesis:degree_name":["Master of Science (MS)"]},"updated_at":"2026-11-19T07:08:14Z"}