{"id":{"repo_id":"clemson","oai_identifier":"oai:open.clemson.edu:all_theses-2965"},"canonical_url":"https://search.ndltd.org/etd/clemson/oai:open.clemson.edu:all_theses-2965","repository":{"repo_id":"clemson","name":"Clemson University","base_url":"https://open.clemson.edu/do/oai/"},"display":{"title":"POST-TENSIONING TO PREVENT END-REGION CRACKS IN PRETENSIONED CONCRETE GIRDERS","abstract":"Web-splitting cracking during and immediately after prestress transfer is a common problem in pretensioned concrete beams, often with lasting effects on the durability and performance. By providing an entry point for chlorides and other corrosives, end-region cracks enable degradation of reinforcing steel and further cracking. Current practices offer a variety of methods for controlling end-region cracking. However, methods for preventing--not just controlling or repairing--end-region cracks are necessary to improve prestressed concrete construction. Vertical end-region post-tensioning is a developing method for preventing web-splitting cracks. The purpose of this document is to explore implementation methods of post-tensioning using the turn-of-the nut procedure, to apply post-tensioning on inverted T-beam specimens, and to develop a finite element model to calculate web-splitting stress distributions. The effectiveness of the post-tensioning is evaluated in terms of its ease of implementations, ability to prevent and control cracking, and impact on sustainability and resilience. Results indicate that end-region post-tensioning can be easily and effectively applied using a calibrated turn-of-the-nut procedure to prevent and control end-region cracking.","abstract_html":"Web-splitting cracking during and immediately after prestress transfer is a common problem in pretensioned concrete beams, often with lasting effects on the durability and performance. By providing an entry point for chlorides and other corrosives, end-region cracks enable degradation of reinforcing steel and further cracking. Current practices offer a variety of methods for controlling end-region cracking. However, methods for preventing--not just controlling or repairing--end-region cracks are necessary to improve prestressed concrete construction. Vertical end-region post-tensioning is a developing method for preventing web-splitting cracks. The purpose of this document is to explore implementation methods of post-tensioning using the turn-of-the nut procedure, to apply post-tensioning on inverted T-beam specimens, and to develop a finite element model to calculate web-splitting stress distributions. The effectiveness of the post-tensioning is evaluated in terms of its ease of implementations, ability to prevent and control cracking, and impact on sustainability and resilience. Results indicate that end-region post-tensioning can be easily and effectively applied using a calibrated turn-of-the-nut procedure to prevent and control end-region cracking.","abstract_has_math":false,"creators":["Willis, Michael"],"institution":null,"degree_name":"Master of Science (MS)","degree_level":"Thesis","degree_discipline":"Civil Engineering","degree_department":null,"school":null,"contributors":["Ross, Brandon E","Atamturktur , Sezer","Rangaraju , Prasad"],"advisors":[],"committee_chairs":[],"committee_members":[],"year":null,"date_issued":"","date_published":null,"updated_at":"2026-11-19T07:11:26Z","subjects":["Cracking","End region","End zone","Posttensioning","Precast","Prestressing","Civil Engineering"],"languages":[],"rights":[],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"https://open.clemson.edu/all_theses/1963","outbound_label":"Repository record","outbound_source":"dc:identifier","record_url":"https://open.clemson.edu/all_theses/1963","record_label":"Repository record","record_kind":"record","record_source":"dc:identifier","download_url":null,"download_label":null,"download_source":null,"access_status":null,"embargo_until":null,"access_note":null},"source_record":{"url":"https://open.clemson.edu/do/oai/?verb=GetRecord&metadataPrefix=oai_etdms&identifier=oai%3Aopen.clemson.edu%3Aall_theses-2965","prefix":"oai_etdms"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor","label":"Contributor","values":["Ross, Brandon E","Atamturktur , Sezer","Rangaraju , Prasad"]},{"key":"dc:creator","label":"Author","values":["Willis, Michael"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.available","label":"Dc Date Available","values":["2015-09-30T07:00:00Z"]},{"key":"dc:date.created","label":"Dc Date Created","values":["2014-05-01T07:00:00Z"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Civil Engineering"]},{"key":"thesis:degree_level","label":"Degree Level","values":["Thesis"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Master of Science (MS)"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Cracking","End region","End zone","Posttensioning","Precast","Prestressing","Civil Engineering"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier","label":"Identifier","values":["https://open.clemson.edu/all_theses/1963"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["Web-splitting cracking during and immediately after prestress transfer is a common problem in pretensioned concrete beams, often with lasting effects on the durability and performance. By providing an entry point for chlorides and other corrosives, end-region cracks enable degradation of reinforcing steel and further cracking. Current practices offer a variety of methods for controlling end-region cracking. However, methods for preventing--not just controlling or repairing--end-region cracks are necessary to improve prestressed concrete construction. Vertical end-region post-tensioning is a developing method for preventing web-splitting cracks. The purpose of this document is to explore implementation methods of post-tensioning using the turn-of-the nut procedure, to apply post-tensioning on inverted T-beam specimens, and to develop a finite element model to calculate web-splitting stress distributions. The effectiveness of the post-tensioning is evaluated in terms of its ease of implementations, ability to prevent and control cracking, and impact on sustainability and resilience. Results indicate that end-region post-tensioning can be easily and effectively applied using a calibrated turn-of-the-nut procedure to prevent and control end-region cracking."]},{"key":"dc:title","label":"Title","values":["POST-TENSIONING TO PREVENT END-REGION CRACKS IN PRETENSIONED CONCRETE GIRDERS"]}]}],"canonical_facts":{"dc:contributor":["Ross, Brandon E","Atamturktur , Sezer","Rangaraju , Prasad"],"dc:creator":["Willis, Michael"],"dc:date.available":["2015-09-30T07:00:00Z"],"dc:date.created":["2014-05-01T07:00:00Z"],"dc:description.abstract":["Web-splitting cracking during and immediately after prestress transfer is a common problem in pretensioned concrete beams, often with lasting effects on the durability and performance. By providing an entry point for chlorides and other corrosives, end-region cracks enable degradation of reinforcing steel and further cracking. Current practices offer a variety of methods for controlling end-region cracking. However, methods for preventing--not just controlling or repairing--end-region cracks are necessary to improve prestressed concrete construction. Vertical end-region post-tensioning is a developing method for preventing web-splitting cracks. The purpose of this document is to explore implementation methods of post-tensioning using the turn-of-the nut procedure, to apply post-tensioning on inverted T-beam specimens, and to develop a finite element model to calculate web-splitting stress distributions. The effectiveness of the post-tensioning is evaluated in terms of its ease of implementations, ability to prevent and control cracking, and impact on sustainability and resilience. Results indicate that end-region post-tensioning can be easily and effectively applied using a calibrated turn-of-the-nut procedure to prevent and control end-region cracking."],"dc:identifier":["https://open.clemson.edu/all_theses/1963"],"dc:subject":["Cracking","End region","End zone","Posttensioning","Precast","Prestressing","Civil Engineering"],"dc:title":["POST-TENSIONING TO PREVENT END-REGION CRACKS IN PRETENSIONED CONCRETE GIRDERS"],"thesis:degree_discipline":["Civil Engineering"],"thesis:degree_level":["Thesis"],"thesis:degree_name":["Master of Science (MS)"]},"updated_at":"2026-11-19T07:11:26Z"}