{"id":{"repo_id":"clemson","oai_identifier":"oai:open.clemson.edu:all_theses-4030"},"canonical_url":"https://search.ndltd.org/etd/clemson/oai:open.clemson.edu:all_theses-4030","repository":{"repo_id":"clemson","name":"Clemson University","base_url":"https://open.clemson.edu/do/oai/"},"display":{"title":"Thermal Neutron Characterization and Dose Modeling of a Plutonium-239/Beryllium Alpha-Neutron Source","abstract":"Determination of neutron dose can be challenging and requires knowledge of neutron energy and neutron flux. A plutonium-239/beryllium (239PuBe) alpha-neutron source was used to irradiate bacterial samples to create neutron dose response. The goal of this project was to characterize the thermal neutron flux of the 239PuBe alpha-neutron source and model the neutron dose using version MCNPX of the Monte-Carlo N-Particle transport codes. The 37 GBq 239PuBe alpha-neutron source was placed in a neutron “howitzer,” that is, a 2-ft diameter moderating barrel with four radial irradiation ports. Multi-foil activation was used at various distances to determine thermal neutron flux, which was then used to verify a MCNPX code representing the system. Dysprosium thermal foils were used with cadmium covers. The MCNPX code was then adapted for dosimetric modeling. That is, the F5 tally, with a dose function, was used in place of the F4 tally. The four irradiation ports were found to have average thermal neutron fluxes of 5334 ± 829, 2928 ± 451, 1289 ± 199, and 1211 ± 186 neutrons cm-2 s-1 at 3.58, 9.04, 12.8, and 13.7 cm from the 239PuBe alpha-neutron source, respectively. The adapted MCNPX code calculated theoretical total ambient dose equivalent rates of 1717 ± 90.2, 703 ± 37.0, 286 ± 15.0, and 174 ± 9.18 mrem hr-1 at 4, 8, 14, and 18 cm from the 239PuBe alpha-neutron source, respectively. The theoretical direct (uncollided) ambient dose equivalent rates at the same distances were 837 ± 44.0, 272 ± 14.3, 100 ± 5.29, and 63.1 ± 3.32 mrem hr-1, respectively. Rough estimates of the absorbed dose rates were made from the ambient dose equivalent rates and a recommendation of 23.6 cm from the PuBe source was made to achieve an absorbed dose rate of roughly 10 mGy d-1.","abstract_html":"Determination of neutron dose can be challenging and requires knowledge of neutron energy and neutron flux. A plutonium-239/beryllium (239PuBe) alpha-neutron source was used to irradiate bacterial samples to create neutron dose response. The goal of this project was to characterize the thermal neutron flux of the 239PuBe alpha-neutron source and model the neutron dose using version MCNPX of the Monte-Carlo N-Particle transport codes. The 37 GBq 239PuBe alpha-neutron source was placed in a neutron “howitzer,” that is, a 2-ft diameter moderating barrel with four radial irradiation ports. Multi-foil activation was used at various distances to determine thermal neutron flux, which was then used to verify a MCNPX code representing the system. Dysprosium thermal foils were used with cadmium covers. The MCNPX code was then adapted for dosimetric modeling. That is, the F5 tally, with a dose function, was used in place of the F4 tally. The four irradiation ports were found to have average thermal neutron fluxes of 5334 ± 829, 2928 ± 451, 1289 ± 199, and 1211 ± 186 neutrons cm-2 s-1 at 3.58, 9.04, 12.8, and 13.7 cm from the 239PuBe alpha-neutron source, respectively. The adapted MCNPX code calculated theoretical total ambient dose equivalent rates of 1717 ± 90.2, 703 ± 37.0, 286 ± 15.0, and 174 ± 9.18 mrem hr-1 at 4, 8, 14, and 18 cm from the 239PuBe alpha-neutron source, respectively. The theoretical direct (uncollided) ambient dose equivalent rates at the same distances were 837 ± 44.0, 272 ± 14.3, 100 ± 5.29, and 63.1 ± 3.32 mrem hr-1, respectively. Rough estimates of the absorbed dose rates were made from the ambient dose equivalent rates and a recommendation of 23.6 cm from the PuBe source was made to achieve an absorbed dose rate of roughly 10 mGy d-1.","abstract_has_math":false,"creators":["Willey, Adam Hunter"],"institution":null,"degree_name":"Master of Science (MS)","degree_level":"Thesis","degree_discipline":"Environmental Engineering and Earth Sciences","degree_department":null,"school":null,"contributors":["Dr. Nicole E. Martinez, Committee Chair","Dr. Timothy A. DeVol","Dr. Mark A. Blenner"],"advisors":[],"committee_chairs":[],"committee_members":[],"year":null,"date_issued":"","date_published":null,"updated_at":"2026-11-19T07:19:26Z","subjects":["Activation","Alpha Neutron Source","Neutron Dose","Neutron Flux","Thermal Neutron"],"languages":[],"rights":[],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"https://open.clemson.edu/all_theses/3023","outbound_label":"Repository record","outbound_source":"dc:identifier","record_url":"https://open.clemson.edu/all_theses/3023","record_label":"Repository record","record_kind":"record","record_source":"dc:identifier","download_url":null,"download_label":null,"download_source":null,"access_status":null,"embargo_until":null,"access_note":null},"source_record":{"url":"https://open.clemson.edu/do/oai/?verb=GetRecord&metadataPrefix=oai_etdms&identifier=oai%3Aopen.clemson.edu%3Aall_theses-4030","prefix":"oai_etdms"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor","label":"Contributor","values":["Dr. Nicole E. Martinez, Committee Chair","Dr. Timothy A. DeVol","Dr. Mark A. Blenner"]},{"key":"dc:creator","label":"Author","values":["Willey, Adam Hunter"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.available","label":"Dc Date Available","values":["2019-03-06T19:15:58Z"]},{"key":"dc:date.created","label":"Dc Date Created","values":["2018-12-01T08:00:00Z"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Environmental Engineering and Earth Sciences"]},{"key":"thesis:degree_level","label":"Degree Level","values":["Thesis"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Master of Science (MS)"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Activation","Alpha Neutron Source","Neutron Dose","Neutron Flux","Thermal Neutron"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier","label":"Identifier","values":["https://open.clemson.edu/all_theses/3023"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["Determination of neutron dose can be challenging and requires knowledge of neutron energy and neutron flux. A plutonium-239/beryllium (239PuBe) alpha-neutron source was used to irradiate bacterial samples to create neutron dose response. The goal of this project was to characterize the thermal neutron flux of the 239PuBe alpha-neutron source and model the neutron dose using version MCNPX of the Monte-Carlo N-Particle transport codes. The 37 GBq 239PuBe alpha-neutron source was placed in a neutron “howitzer,” that is, a 2-ft diameter moderating barrel with four radial irradiation ports. Multi-foil activation was used at various distances to determine thermal neutron flux, which was then used to verify a MCNPX code representing the system. Dysprosium thermal foils were used with cadmium covers. The MCNPX code was then adapted for dosimetric modeling. That is, the F5 tally, with a dose function, was used in place of the F4 tally. The four irradiation ports were found to have average thermal neutron fluxes of 5334 ± 829, 2928 ± 451, 1289 ± 199, and 1211 ± 186 neutrons cm-2 s-1 at 3.58, 9.04, 12.8, and 13.7 cm from the 239PuBe alpha-neutron source, respectively. The adapted MCNPX code calculated theoretical total ambient dose equivalent rates of 1717 ± 90.2, 703 ± 37.0, 286 ± 15.0, and 174 ± 9.18 mrem hr-1 at 4, 8, 14, and 18 cm from the 239PuBe alpha-neutron source, respectively. The theoretical direct (uncollided) ambient dose equivalent rates at the same distances were 837 ± 44.0, 272 ± 14.3, 100 ± 5.29, and 63.1 ± 3.32 mrem hr-1, respectively. Rough estimates of the absorbed dose rates were made from the ambient dose equivalent rates and a recommendation of 23.6 cm from the PuBe source was made to achieve an absorbed dose rate of roughly 10 mGy d-1."]},{"key":"dc:title","label":"Title","values":["Thermal Neutron Characterization and Dose Modeling of a Plutonium-239/Beryllium Alpha-Neutron Source"]}]}],"canonical_facts":{"dc:contributor":["Dr. Nicole E. Martinez, Committee Chair","Dr. Timothy A. DeVol","Dr. Mark A. Blenner"],"dc:creator":["Willey, Adam Hunter"],"dc:date.available":["2019-03-06T19:15:58Z"],"dc:date.created":["2018-12-01T08:00:00Z"],"dc:description.abstract":["Determination of neutron dose can be challenging and requires knowledge of neutron energy and neutron flux. A plutonium-239/beryllium (239PuBe) alpha-neutron source was used to irradiate bacterial samples to create neutron dose response. The goal of this project was to characterize the thermal neutron flux of the 239PuBe alpha-neutron source and model the neutron dose using version MCNPX of the Monte-Carlo N-Particle transport codes. The 37 GBq 239PuBe alpha-neutron source was placed in a neutron “howitzer,” that is, a 2-ft diameter moderating barrel with four radial irradiation ports. Multi-foil activation was used at various distances to determine thermal neutron flux, which was then used to verify a MCNPX code representing the system. Dysprosium thermal foils were used with cadmium covers. The MCNPX code was then adapted for dosimetric modeling. That is, the F5 tally, with a dose function, was used in place of the F4 tally. The four irradiation ports were found to have average thermal neutron fluxes of 5334 ± 829, 2928 ± 451, 1289 ± 199, and 1211 ± 186 neutrons cm-2 s-1 at 3.58, 9.04, 12.8, and 13.7 cm from the 239PuBe alpha-neutron source, respectively. The adapted MCNPX code calculated theoretical total ambient dose equivalent rates of 1717 ± 90.2, 703 ± 37.0, 286 ± 15.0, and 174 ± 9.18 mrem hr-1 at 4, 8, 14, and 18 cm from the 239PuBe alpha-neutron source, respectively. The theoretical direct (uncollided) ambient dose equivalent rates at the same distances were 837 ± 44.0, 272 ± 14.3, 100 ± 5.29, and 63.1 ± 3.32 mrem hr-1, respectively. Rough estimates of the absorbed dose rates were made from the ambient dose equivalent rates and a recommendation of 23.6 cm from the PuBe source was made to achieve an absorbed dose rate of roughly 10 mGy d-1."],"dc:identifier":["https://open.clemson.edu/all_theses/3023"],"dc:subject":["Activation","Alpha Neutron Source","Neutron Dose","Neutron Flux","Thermal Neutron"],"dc:title":["Thermal Neutron Characterization and Dose Modeling of a Plutonium-239/Beryllium Alpha-Neutron Source"],"thesis:degree_discipline":["Environmental Engineering and Earth Sciences"],"thesis:degree_level":["Thesis"],"thesis:degree_name":["Master of Science (MS)"]},"updated_at":"2026-11-19T07:19:26Z"}