{"id":{"repo_id":"clemson","oai_identifier":"oai:open.clemson.edu:all_theses-5124"},"canonical_url":"https://search.ndltd.org/etd/clemson/oai:open.clemson.edu:all_theses-5124","repository":{"repo_id":"clemson","name":"Clemson University","base_url":"https://open.clemson.edu/do/oai/"},"display":{"title":"Effect of Transverse Post-Tensioning on Moment Distribution Between Channel Girders","abstract":"This thesis investigates the strength of prestressed concrete channel girders used in bridges in South Carolina and how to improve their load distribution. The specimens are 30 feet in length, 33 inches wide and 17 inches deep. South Carolina has 377 bridges containing prestressed concrete channel girders and many of these bridges received a poor load rating in a recent load rating project conducted by the South Carolina Department of Transportation (SCDOT). The research included flexural testing of seven individual channel girders and load distribution tests of three transversely post-tensioned channel girders. Individual flexural testing was done to determine the moment capacity of channel girders that were extracted from out of service bridges and load distribution testing was done to determine if transverse post-tensioning was a promising method of improving transverse load distribution. Increasing load distribution would lower moment demand on an individual girder and therefore increase load ratings. From the lab testing, the girders in good condition were found to be stronger than calculated, but girders in poor condition were weaker than the calculated flexural strength. The load distribution tests also produced good results with transverse post-tensioning improving load distribution. The outcomes of these tests can be used to reevaluate the results of load ratings of channel girder bridges in the field and possibly implement the solution of transverse post-tensioning.","abstract_html":"This thesis investigates the strength of prestressed concrete channel girders used in bridges in South Carolina and how to improve their load distribution. The specimens are 30 feet in length, 33 inches wide and 17 inches deep. South Carolina has 377 bridges containing prestressed concrete channel girders and many of these bridges received a poor load rating in a recent load rating project conducted by the South Carolina Department of Transportation (SCDOT). The research included flexural testing of seven individual channel girders and load distribution tests of three transversely post-tensioned channel girders. Individual flexural testing was done to determine the moment capacity of channel girders that were extracted from out of service bridges and load distribution testing was done to determine if transverse post-tensioning was a promising method of improving transverse load distribution. Increasing load distribution would lower moment demand on an individual girder and therefore increase load ratings. From the lab testing, the girders in good condition were found to be stronger than calculated, but girders in poor condition were weaker than the calculated flexural strength. The load distribution tests also produced good results with transverse post-tensioning improving load distribution. The outcomes of these tests can be used to reevaluate the results of load ratings of channel girder bridges in the field and possibly implement the solution of transverse post-tensioning.","abstract_has_math":false,"creators":["Eubanks, William"],"institution":null,"degree_name":"Master of Science (MS)","degree_level":"Thesis","degree_discipline":"Civil Engineering","degree_department":null,"school":null,"contributors":["Brandon E. Ross","Thomas E. Cousins","Michael W. Stoner"],"advisors":[],"committee_chairs":[],"committee_members":[],"year":null,"date_issued":"","date_published":null,"updated_at":"2026-11-19T07:31:04Z","subjects":["Structural Engineering","Infrastructure","Retro-fit","Channel Bridges","Prestressed Concrete","Transverse Post-Tensioning","Moment Distribution","South Carolina"],"languages":[],"rights":[],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"https://open.clemson.edu/all_theses/4108","outbound_label":"Repository record","outbound_source":"dc:identifier","record_url":"https://open.clemson.edu/all_theses/4108","record_label":"Repository record","record_kind":"record","record_source":"dc:identifier","download_url":null,"download_label":null,"download_source":null,"access_status":null,"embargo_until":null,"access_note":null},"source_record":{"url":"https://open.clemson.edu/do/oai/?verb=GetRecord&metadataPrefix=oai_etdms&identifier=oai%3Aopen.clemson.edu%3Aall_theses-5124","prefix":"oai_etdms"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor","label":"Contributor","values":["Brandon E. Ross","Thomas E. Cousins","Michael W. Stoner"]},{"key":"dc:creator","label":"Author","values":["Eubanks, William"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.available","label":"Dc Date Available","values":["2023-07-20T07:00:00Z"]},{"key":"dc:date.created","label":"Dc Date Created","values":["2023-08-01T07:00:00Z"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Civil Engineering"]},{"key":"thesis:degree_level","label":"Degree Level","values":["Thesis"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Master of Science (MS)"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Structural Engineering","Infrastructure","Retro-fit","Channel Bridges","Prestressed Concrete","Transverse Post-Tensioning","Moment Distribution","South Carolina"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier","label":"Identifier","values":["https://open.clemson.edu/all_theses/4108"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["This thesis investigates the strength of prestressed concrete channel girders used in bridges in South Carolina and how to improve their load distribution. The specimens are 30 feet in length, 33 inches wide and 17 inches deep. South Carolina has 377 bridges containing prestressed concrete channel girders and many of these bridges received a poor load rating in a recent load rating project conducted by the South Carolina Department of Transportation (SCDOT). The research included flexural testing of seven individual channel girders and load distribution tests of three transversely post-tensioned channel girders. Individual flexural testing was done to determine the moment capacity of channel girders that were extracted from out of service bridges and load distribution testing was done to determine if transverse post-tensioning was a promising method of improving transverse load distribution. Increasing load distribution would lower moment demand on an individual girder and therefore increase load ratings. From the lab testing, the girders in good condition were found to be stronger than calculated, but girders in poor condition were weaker than the calculated flexural strength. The load distribution tests also produced good results with transverse post-tensioning improving load distribution. The outcomes of these tests can be used to reevaluate the results of load ratings of channel girder bridges in the field and possibly implement the solution of transverse post-tensioning."]},{"key":"dc:title","label":"Title","values":["Effect of Transverse Post-Tensioning on Moment Distribution Between Channel Girders"]}]}],"canonical_facts":{"dc:contributor":["Brandon E. Ross","Thomas E. Cousins","Michael W. Stoner"],"dc:creator":["Eubanks, William"],"dc:date.available":["2023-07-20T07:00:00Z"],"dc:date.created":["2023-08-01T07:00:00Z"],"dc:description.abstract":["This thesis investigates the strength of prestressed concrete channel girders used in bridges in South Carolina and how to improve their load distribution. The specimens are 30 feet in length, 33 inches wide and 17 inches deep. South Carolina has 377 bridges containing prestressed concrete channel girders and many of these bridges received a poor load rating in a recent load rating project conducted by the South Carolina Department of Transportation (SCDOT). The research included flexural testing of seven individual channel girders and load distribution tests of three transversely post-tensioned channel girders. Individual flexural testing was done to determine the moment capacity of channel girders that were extracted from out of service bridges and load distribution testing was done to determine if transverse post-tensioning was a promising method of improving transverse load distribution. Increasing load distribution would lower moment demand on an individual girder and therefore increase load ratings. From the lab testing, the girders in good condition were found to be stronger than calculated, but girders in poor condition were weaker than the calculated flexural strength. The load distribution tests also produced good results with transverse post-tensioning improving load distribution. The outcomes of these tests can be used to reevaluate the results of load ratings of channel girder bridges in the field and possibly implement the solution of transverse post-tensioning."],"dc:identifier":["https://open.clemson.edu/all_theses/4108"],"dc:subject":["Structural Engineering","Infrastructure","Retro-fit","Channel Bridges","Prestressed Concrete","Transverse Post-Tensioning","Moment Distribution","South Carolina"],"dc:title":["Effect of Transverse Post-Tensioning on Moment Distribution Between Channel Girders"],"thesis:degree_discipline":["Civil Engineering"],"thesis:degree_level":["Thesis"],"thesis:degree_name":["Master of Science (MS)"]},"updated_at":"2026-11-19T07:31:04Z"}