{"id":{"repo_id":"clemson","oai_identifier":"oai:open.clemson.edu:all_theses-5264"},"canonical_url":"https://search.ndltd.org/etd/clemson/oai:open.clemson.edu:all_theses-5264","repository":{"repo_id":"clemson","name":"Clemson University","base_url":"https://open.clemson.edu/do/oai/"},"display":{"title":"Hand Movement Analysis for Surgical Suturing Skill Assessment","abstract":"To enhance patient safety, surgical education is increasingly incorporating simulation for formative skills assessment and training. However, many standardized assessment tools rely on human raters for performance assessment, which is resource-intensive and subjective. Simulators that provide automated and objective metrics from sensor data can address this limitation. This thesis presents an instrumented bench suturing simulator, patterned after the Clock Face (CF) radial suturing model from the Fundamentals of Vascular Surgery (FVS), for automated and objective assessment of open suturing skills by particularly focusing on biomechanical analysis of hand movements. For this research, 97 participants (35 attending surgeons and fellows, 32 surgical residents, and 30 novices) were recruited at national vascular conferences. Automated hand motion metrics, especially focusing on rotational motion analysis, were developed from the Inertial Measurement Unit (IMU) attached to participants’ hands, and the proposed suite of metrics was used to differentiate between skill levels of the three groups. Further, the application of functional data analysis (FDA) to hand roll velocity during radial suturing on the SutureCoach bench simulator for evaluating open suturing performance was studied. By treating temporal sensor data as mathematical functions, FDA provides a holistic view of the dynamic changes in hand roll, offering comprehensive assessments that are easily interpretable and clinically relevant. Cluster analysis was performed on the hand roll profile of subjects, and the relationship between cluster membership and suturing skills was corroborated using proxy measures of skill, such as expert Global Rating Scale evaluation, clinical status, and specific simulator metrics. This thesis provides evidence for the effectiveness of rotational motion analysis for assessing suturing skills. The IMU-based hand motion metrics introduced in this study allow for incorporating hand movement data for suturing skill assessment. Moreover, the clinical relevance of our results extends to the broader field of surgical skill assessment and training, as analyses of this thesis are scalable and adaptable to a wide range of surgical tasks beyond suturing.","abstract_html":"To enhance patient safety, surgical education is increasingly incorporating simulation for formative skills assessment and training. However, many standardized assessment tools rely on human raters for performance assessment, which is resource-intensive and subjective. Simulators that provide automated and objective metrics from sensor data can address this limitation. This thesis presents an instrumented bench suturing simulator, patterned after the Clock Face (CF) radial suturing model from the Fundamentals of Vascular Surgery (FVS), for automated and objective assessment of open suturing skills by particularly focusing on biomechanical analysis of hand movements. For this research, 97 participants (35 attending surgeons and fellows, 32 surgical residents, and 30 novices) were recruited at national vascular conferences. Automated hand motion metrics, especially focusing on rotational motion analysis, were developed from the Inertial Measurement Unit (IMU) attached to participants’ hands, and the proposed suite of metrics was used to differentiate between skill levels of the three groups. Further, the application of functional data analysis (FDA) to hand roll velocity during radial suturing on the SutureCoach bench simulator for evaluating open suturing performance was studied. By treating temporal sensor data as mathematical functions, FDA provides a holistic view of the dynamic changes in hand roll, offering comprehensive assessments that are easily interpretable and clinically relevant. Cluster analysis was performed on the hand roll profile of subjects, and the relationship between cluster membership and suturing skills was corroborated using proxy measures of skill, such as expert Global Rating Scale evaluation, clinical status, and specific simulator metrics. This thesis provides evidence for the effectiveness of rotational motion analysis for assessing suturing skills. The IMU-based hand motion metrics introduced in this study allow for incorporating hand movement data for suturing skill assessment. Moreover, the clinical relevance of our results extends to the broader field of surgical skill assessment and training, as analyses of this thesis are scalable and adaptable to a wide range of surgical tasks beyond suturing.","abstract_has_math":false,"creators":["Shayan, Amir Mehdi"],"institution":null,"degree_name":"Master of Science (MS)","degree_level":"Thesis","degree_discipline":"Bioengineering","degree_department":null,"school":null,"contributors":["Dr. Joseph Singapogu","Dr. Richard E. Groff","Dr. Jeremy Mercuri"],"advisors":[],"committee_chairs":[],"committee_members":[],"year":null,"date_issued":"","date_published":null,"updated_at":"2026-11-19T07:31:26Z","subjects":["Surgical Simulation","Automated Skill Assessment","Biomechanical Analysis","Hand Motion Metrics","Rotational Motion Analysis","Functional Data Analysis (FDA)","Unsupervised Clustering","Dynamic Time Warping","Suturing Skills Assessment","Bioelectrical and Neuroengineering","Biomechanics and Biotransport","Biomedical","Biomedical Devices and Instrumentation","Medical Education","Robotics"],"languages":[],"rights":[],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"https://open.clemson.edu/all_theses/4285","outbound_label":"Repository record","outbound_source":"dc:identifier","record_url":"https://open.clemson.edu/all_theses/4285","record_label":"Repository record","record_kind":"record","record_source":"dc:identifier","download_url":null,"download_label":null,"download_source":null,"access_status":null,"embargo_until":null,"access_note":null},"source_record":{"url":"https://open.clemson.edu/do/oai/?verb=GetRecord&metadataPrefix=oai_etdms&identifier=oai%3Aopen.clemson.edu%3Aall_theses-5264","prefix":"oai_etdms"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor","label":"Contributor","values":["Dr. Joseph Singapogu","Dr. Richard E. Groff","Dr. Jeremy Mercuri"]},{"key":"dc:creator","label":"Author","values":["Shayan, Amir Mehdi"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.available","label":"Dc Date Available","values":["2025-05-31T07:00:00Z"]},{"key":"dc:date.created","label":"Dc Date Created","values":["2024-05-01T07:00:00Z"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Bioengineering"]},{"key":"thesis:degree_level","label":"Degree Level","values":["Thesis"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Master of Science (MS)"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Surgical Simulation","Automated Skill Assessment","Biomechanical Analysis","Hand Motion Metrics","Rotational Motion Analysis","Functional Data Analysis (FDA)","Unsupervised Clustering","Dynamic Time Warping","Suturing Skills Assessment","Bioelectrical and Neuroengineering","Biomechanics and Biotransport","Biomedical","Biomedical Devices and Instrumentation","Medical Education","Robotics"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier","label":"Identifier","values":["https://open.clemson.edu/all_theses/4285"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["To enhance patient safety, surgical education is increasingly incorporating simulation for formative skills assessment and training. However, many standardized assessment tools rely on human raters for performance assessment, which is resource-intensive and subjective. Simulators that provide automated and objective metrics from sensor data can address this limitation. This thesis presents an instrumented bench suturing simulator, patterned after the Clock Face (CF) radial suturing model from the Fundamentals of Vascular Surgery (FVS), for automated and objective assessment of open suturing skills by particularly focusing on biomechanical analysis of hand movements. For this research, 97 participants (35 attending surgeons and fellows, 32 surgical residents, and 30 novices) were recruited at national vascular conferences. Automated hand motion metrics, especially focusing on rotational motion analysis, were developed from the Inertial Measurement Unit (IMU) attached to participants’ hands, and the proposed suite of metrics was used to differentiate between skill levels of the three groups. Further, the application of functional data analysis (FDA) to hand roll velocity during radial suturing on the SutureCoach bench simulator for evaluating open suturing performance was studied. By treating temporal sensor data as mathematical functions, FDA provides a holistic view of the dynamic changes in hand roll, offering comprehensive assessments that are easily interpretable and clinically relevant. Cluster analysis was performed on the hand roll profile of subjects, and the relationship between cluster membership and suturing skills was corroborated using proxy measures of skill, such as expert Global Rating Scale evaluation, clinical status, and specific simulator metrics. This thesis provides evidence for the effectiveness of rotational motion analysis for assessing suturing skills. The IMU-based hand motion metrics introduced in this study allow for incorporating hand movement data for suturing skill assessment. Moreover, the clinical relevance of our results extends to the broader field of surgical skill assessment and training, as analyses of this thesis are scalable and adaptable to a wide range of surgical tasks beyond suturing."]},{"key":"dc:title","label":"Title","values":["Hand Movement Analysis for Surgical Suturing Skill Assessment"]}]}],"canonical_facts":{"dc:contributor":["Dr. Joseph Singapogu","Dr. Richard E. Groff","Dr. Jeremy Mercuri"],"dc:creator":["Shayan, Amir Mehdi"],"dc:date.available":["2025-05-31T07:00:00Z"],"dc:date.created":["2024-05-01T07:00:00Z"],"dc:description.abstract":["To enhance patient safety, surgical education is increasingly incorporating simulation for formative skills assessment and training. However, many standardized assessment tools rely on human raters for performance assessment, which is resource-intensive and subjective. Simulators that provide automated and objective metrics from sensor data can address this limitation. This thesis presents an instrumented bench suturing simulator, patterned after the Clock Face (CF) radial suturing model from the Fundamentals of Vascular Surgery (FVS), for automated and objective assessment of open suturing skills by particularly focusing on biomechanical analysis of hand movements. For this research, 97 participants (35 attending surgeons and fellows, 32 surgical residents, and 30 novices) were recruited at national vascular conferences. Automated hand motion metrics, especially focusing on rotational motion analysis, were developed from the Inertial Measurement Unit (IMU) attached to participants’ hands, and the proposed suite of metrics was used to differentiate between skill levels of the three groups. Further, the application of functional data analysis (FDA) to hand roll velocity during radial suturing on the SutureCoach bench simulator for evaluating open suturing performance was studied. By treating temporal sensor data as mathematical functions, FDA provides a holistic view of the dynamic changes in hand roll, offering comprehensive assessments that are easily interpretable and clinically relevant. Cluster analysis was performed on the hand roll profile of subjects, and the relationship between cluster membership and suturing skills was corroborated using proxy measures of skill, such as expert Global Rating Scale evaluation, clinical status, and specific simulator metrics. This thesis provides evidence for the effectiveness of rotational motion analysis for assessing suturing skills. The IMU-based hand motion metrics introduced in this study allow for incorporating hand movement data for suturing skill assessment. Moreover, the clinical relevance of our results extends to the broader field of surgical skill assessment and training, as analyses of this thesis are scalable and adaptable to a wide range of surgical tasks beyond suturing."],"dc:identifier":["https://open.clemson.edu/all_theses/4285"],"dc:subject":["Surgical Simulation","Automated Skill Assessment","Biomechanical Analysis","Hand Motion Metrics","Rotational Motion Analysis","Functional Data Analysis (FDA)","Unsupervised Clustering","Dynamic Time Warping","Suturing Skills Assessment","Bioelectrical and Neuroengineering","Biomechanics and Biotransport","Biomedical","Biomedical Devices and Instrumentation","Medical Education","Robotics"],"dc:title":["Hand Movement Analysis for Surgical Suturing Skill Assessment"],"thesis:degree_discipline":["Bioengineering"],"thesis:degree_level":["Thesis"],"thesis:degree_name":["Master of Science (MS)"]},"updated_at":"2026-11-19T07:31:26Z"}