{"id":{"repo_id":"clemson","oai_identifier":"oai:open.clemson.edu:all_theses-5781"},"canonical_url":"https://search.ndltd.org/etd/clemson/oai:open.clemson.edu:all_theses-5781","repository":{"repo_id":"clemson","name":"Clemson University","base_url":"https://open.clemson.edu/do/oai/"},"display":{"title":"Taking a Deeper Look: Attributing Tonal Values of Photolumens to Their Emulsions Using Scanning Electron Microscopy","abstract":"This thesis examines whether tonal variation in photolumens made with historic silver gelatin photographic papers can be linked to differences in elemental composition. Photolumens are cameraless photographic images created by placing objects directly on light-sensitive paper and exposing them to ultraviolet light. Because expired and historic darkroom papers often produce unpredictable colors and tones, this study asks whether visually defined tonal groups also show measurable chemical differences. Twenty historic paper samples were exposed, documented, and sorted into five tonal groups based on visible image characteristics. Each sample was then analyzed using scanning electron microscopy with energy dispersive X-ray spectroscopy (SEM-EDS) to measure elemental composition by weight percent. Comparative datasets were evaluated across groups, with emphasis on silver and halide-related components because of their importance in traditional photographic emulsions. The study also tested total silver-halide-related content and the ratio of silver to total halides. Because ytterbium appeared in several samples despite being historically unlikely in these materials, a second interpretive model treated the ytterbium signal as a probable bromine peak-overlap artifact. Results showed that many elements were widely distributed and did not independently distinguish tonal groups. No significant relationship was found between tonal group and total silver-halide-related content alone. No significant group differences appeared when the halide balance used the reported ytterbium values directly. However, when ytterbium was reassigned as part of the bromine-related signal, the silver-to-total-halides ratio differed significantly across tonal groups. These findings suggest that emulsion chemistry, especially silver-halide balance, may help explain tonal variation in photolumens, while also highlighting the interpretive limits of SEM-EDS analysis for layered historic photographic materials.","abstract_html":"This thesis examines whether tonal variation in photolumens made with historic silver gelatin photographic papers can be linked to differences in elemental composition. Photolumens are cameraless photographic images created by placing objects directly on light-sensitive paper and exposing them to ultraviolet light. Because expired and historic darkroom papers often produce unpredictable colors and tones, this study asks whether visually defined tonal groups also show measurable chemical differences. Twenty historic paper samples were exposed, documented, and sorted into five tonal groups based on visible image characteristics. Each sample was then analyzed using scanning electron microscopy with energy dispersive X-ray spectroscopy (SEM-EDS) to measure elemental composition by weight percent. Comparative datasets were evaluated across groups, with emphasis on silver and halide-related components because of their importance in traditional photographic emulsions. The study also tested total silver-halide-related content and the ratio of silver to total halides. Because ytterbium appeared in several samples despite being historically unlikely in these materials, a second interpretive model treated the ytterbium signal as a probable bromine peak-overlap artifact. Results showed that many elements were widely distributed and did not independently distinguish tonal groups. No significant relationship was found between tonal group and total silver-halide-related content alone. No significant group differences appeared when the halide balance used the reported ytterbium values directly. However, when ytterbium was reassigned as part of the bromine-related signal, the silver-to-total-halides ratio differed significantly across tonal groups. These findings suggest that emulsion chemistry, especially silver-halide balance, may help explain tonal variation in photolumens, while also highlighting the interpretive limits of SEM-EDS analysis for layered historic photographic materials.","abstract_has_math":false,"creators":["Moore, Anna M"],"institution":null,"degree_name":"Master of Science (MS)","degree_level":"Thesis","degree_discipline":"Graphic Communications","degree_department":null,"school":null,"contributors":["Erica Walker, PHD","Carl Blue, PHD","Elizabeth Carraway, PHD","Prof. Danita Swaney"],"advisors":[],"committee_chairs":[],"committee_members":[],"year":null,"date_issued":"","date_published":null,"updated_at":"2026-11-19T07:34:07Z","subjects":["photolumen","alternative photography","scanning electron microscopy","elemental analysis","photographic emulsion","photography","Analytical Chemistry","Art and Materials Conservation","Art Practice","Biological and Chemical Physics","Interdisciplinary Arts and Media","Materials Chemistry","Other Chemistry","Printmaking"],"languages":[],"rights":[],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"https://open.clemson.edu/all_theses/4734","outbound_label":"Repository record","outbound_source":"dc:identifier","record_url":"https://open.clemson.edu/all_theses/4734","record_label":"Repository record","record_kind":"record","record_source":"dc:identifier","download_url":null,"download_label":null,"download_source":null,"access_status":null,"embargo_until":null,"access_note":null},"source_record":{"url":"https://open.clemson.edu/do/oai/?verb=GetRecord&metadataPrefix=oai_etdms&identifier=oai%3Aopen.clemson.edu%3Aall_theses-5781","prefix":"oai_etdms"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor","label":"Contributor","values":["Erica Walker, PHD","Carl Blue, PHD","Elizabeth Carraway, PHD","Prof. Danita Swaney"]},{"key":"dc:creator","label":"Author","values":["Moore, Anna M"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.available","label":"Dc Date Available","values":["2026-04-16T07:00:00Z"]},{"key":"dc:date.created","label":"Dc Date Created","values":["2026-05-01T07:00:00Z"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Graphic Communications"]},{"key":"thesis:degree_level","label":"Degree Level","values":["Thesis"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Master of Science (MS)"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["photolumen","alternative photography","scanning electron microscopy","elemental analysis","photographic emulsion","photography","Analytical Chemistry","Art and Materials Conservation","Art Practice","Biological and Chemical Physics","Interdisciplinary Arts and Media","Materials Chemistry","Other Chemistry","Printmaking"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier","label":"Identifier","values":["https://open.clemson.edu/all_theses/4734"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["This thesis examines whether tonal variation in photolumens made with historic silver gelatin photographic papers can be linked to differences in elemental composition. Photolumens are cameraless photographic images created by placing objects directly on light-sensitive paper and exposing them to ultraviolet light. Because expired and historic darkroom papers often produce unpredictable colors and tones, this study asks whether visually defined tonal groups also show measurable chemical differences. Twenty historic paper samples were exposed, documented, and sorted into five tonal groups based on visible image characteristics. Each sample was then analyzed using scanning electron microscopy with energy dispersive X-ray spectroscopy (SEM-EDS) to measure elemental composition by weight percent. Comparative datasets were evaluated across groups, with emphasis on silver and halide-related components because of their importance in traditional photographic emulsions. The study also tested total silver-halide-related content and the ratio of silver to total halides. Because ytterbium appeared in several samples despite being historically unlikely in these materials, a second interpretive model treated the ytterbium signal as a probable bromine peak-overlap artifact. Results showed that many elements were widely distributed and did not independently distinguish tonal groups. No significant relationship was found between tonal group and total silver-halide-related content alone. No significant group differences appeared when the halide balance used the reported ytterbium values directly. However, when ytterbium was reassigned as part of the bromine-related signal, the silver-to-total-halides ratio differed significantly across tonal groups. These findings suggest that emulsion chemistry, especially silver-halide balance, may help explain tonal variation in photolumens, while also highlighting the interpretive limits of SEM-EDS analysis for layered historic photographic materials."]},{"key":"dc:title","label":"Title","values":["Taking a Deeper Look: Attributing Tonal Values of Photolumens to Their Emulsions Using Scanning Electron Microscopy"]}]}],"canonical_facts":{"dc:contributor":["Erica Walker, PHD","Carl Blue, PHD","Elizabeth Carraway, PHD","Prof. Danita Swaney"],"dc:creator":["Moore, Anna M"],"dc:date.available":["2026-04-16T07:00:00Z"],"dc:date.created":["2026-05-01T07:00:00Z"],"dc:description.abstract":["This thesis examines whether tonal variation in photolumens made with historic silver gelatin photographic papers can be linked to differences in elemental composition. Photolumens are cameraless photographic images created by placing objects directly on light-sensitive paper and exposing them to ultraviolet light. Because expired and historic darkroom papers often produce unpredictable colors and tones, this study asks whether visually defined tonal groups also show measurable chemical differences. Twenty historic paper samples were exposed, documented, and sorted into five tonal groups based on visible image characteristics. Each sample was then analyzed using scanning electron microscopy with energy dispersive X-ray spectroscopy (SEM-EDS) to measure elemental composition by weight percent. Comparative datasets were evaluated across groups, with emphasis on silver and halide-related components because of their importance in traditional photographic emulsions. The study also tested total silver-halide-related content and the ratio of silver to total halides. Because ytterbium appeared in several samples despite being historically unlikely in these materials, a second interpretive model treated the ytterbium signal as a probable bromine peak-overlap artifact. Results showed that many elements were widely distributed and did not independently distinguish tonal groups. No significant relationship was found between tonal group and total silver-halide-related content alone. No significant group differences appeared when the halide balance used the reported ytterbium values directly. However, when ytterbium was reassigned as part of the bromine-related signal, the silver-to-total-halides ratio differed significantly across tonal groups. These findings suggest that emulsion chemistry, especially silver-halide balance, may help explain tonal variation in photolumens, while also highlighting the interpretive limits of SEM-EDS analysis for layered historic photographic materials."],"dc:identifier":["https://open.clemson.edu/all_theses/4734"],"dc:subject":["photolumen","alternative photography","scanning electron microscopy","elemental analysis","photographic emulsion","photography","Analytical Chemistry","Art and Materials Conservation","Art Practice","Biological and Chemical Physics","Interdisciplinary Arts and Media","Materials Chemistry","Other Chemistry","Printmaking"],"dc:title":["Taking a Deeper Look: Attributing Tonal Values of Photolumens to Their Emulsions Using Scanning Electron Microscopy"],"thesis:degree_discipline":["Graphic Communications"],"thesis:degree_level":["Thesis"],"thesis:degree_name":["Master of Science (MS)"]},"updated_at":"2026-11-19T07:34:07Z"}