{"id":{"repo_id":"colostate","oai_identifier":"oai:mountainscholar.org:10217/234093"},"canonical_url":"https://search.ndltd.org/etd/colostate/oai:mountainscholar.org:10217/234093","repository":{"repo_id":"colostate","name":"Colorado State University","base_url":"https://api.mountainscholar.org/server/oai/request"},"display":{"title":"A system for detecting fluorescent tracers in streamflow","abstract":"A system is developed capable of continuously monitoring the relative concentration of a fluorescent tracer in streamflow. Streamside instrumentation automatically registers stream-borne tracer concentrations as a function of time on a gelatin-coated film. The film is routed through a device which passes a continuous sample-aliquot diverted from the tracer-dosed stream over a small segment of the film. The \"exposed\" film is periodically gathered from stream sites and analyzed in a laboratory-based fluorometer. Utility of the system is studied for the gaging of streamflow to produce a hydrograph, to measure stream discharge instantaneously, and to determine time-of-stream-travel. Hydrographs resulting from 640 hours of gaging two Colorado mountain streams with the system are compared to those obtained from closely located sharp-crested weirs. The maximum instantaneous deviation between hydrographs reaches 10% and average absolute departure equals 1.8%, while algebraic departure averages +0.3%. The practicality of using this system to obtain time-of-stream travels is demonstrated for five Colorado mountain streams. A total of 62 traveling tracer-clouds are registered on gelatin-coated film, from which time-of-stream-travels are determined. Processes involved in the system and factors affecting its precision are investigated. Theoretical and experimental evidence strongly indicates that the bulk of tracer uptake by gelatin follows processes that are physical rather than chemical in nature. Stream temperature changes and duration of film-tracer contact are the two most important factors affecting precision of the system. Neither major factor caused any unsolvable problem when field operations were standardized. The system will have utility in operations where an expensive, temperature-sensitive fluorometer can not be stationed stream-side, and where the particular objectives of stream measurements do not justify the cost of conventional techniques, but where fair accuracy and continuous records of short to moderate duration are desired.","abstract_html":"A system is developed capable of continuously monitoring the relative concentration of a fluorescent tracer in streamflow. Streamside instrumentation automatically registers stream-borne tracer concentrations as a function of time on a gelatin-coated film. The film is routed through a device which passes a continuous sample-aliquot diverted from the tracer-dosed stream over a small segment of the film. The &quot;exposed&quot; film is periodically gathered from stream sites and analyzed in a laboratory-based fluorometer. Utility of the system is studied for the gaging of streamflow to produce a hydrograph, to measure stream discharge instantaneously, and to determine time-of-stream-travel. Hydrographs resulting from 640 hours of gaging two Colorado mountain streams with the system are compared to those obtained from closely located sharp-crested weirs. The maximum instantaneous deviation between hydrographs reaches 10% and average absolute departure equals 1.8%, while algebraic departure averages +0.3%. The practicality of using this system to obtain time-of-stream travels is demonstrated for five Colorado mountain streams. A total of 62 traveling tracer-clouds are registered on gelatin-coated film, from which time-of-stream-travels are determined. Processes involved in the system and factors affecting its precision are investigated. Theoretical and experimental evidence strongly indicates that the bulk of tracer uptake by gelatin follows processes that are physical rather than chemical in nature. Stream temperature changes and duration of film-tracer contact are the two most important factors affecting precision of the system. Neither major factor caused any unsolvable problem when field operations were standardized. The system will have utility in operations where an expensive, temperature-sensitive fluorometer can not be stationed stream-side, and where the particular objectives of stream measurements do not justify the cost of conventional techniques, but where fair accuracy and continuous records of short to moderate duration are desired.","abstract_has_math":false,"creators":["Steppuhn, Harold Wolfgang, author","Meiman, James R. (James Richard), advisor","Dils, Robert E., committee member","Harris, David V., committee member","Johnson, Gestur, 1910-, committee member","Duke, Harold R. (Harold Ray), 1940-, committee member"],"institution":"Colorado State University. Libraries","degree_name":"Doctor of Philosophy (Ph.D.)","degree_level":"Doctoral","degree_discipline":"Watershed Sciences","degree_department":null,"school":null,"contributors":[],"advisors":[],"committee_chairs":[],"committee_members":[],"year":1970,"date_issued":"1970","date_published":"1970","updated_at":"2026-11-19T07:17:35Z","subjects":["Stream measurements -- Colorado","Fluorimetry"],"languages":["eng","English"],"rights":["Copyright and other restrictions may apply. User is responsible for compliance with all applicable laws. For information about copyright law, please see https://libguides.colostate.edu/copyright.","This Item is protected by copyright and/or related rights (https://rightsstatements.org/vocab/InC/1.0/). You are free to use this Item in any way that is permitted by the copyright and related rights legislation that applies to your use. For other uses you need to obtain permission from the rights-holder(s)."],"rights_urls":[],"identifier_entries":[{"key":"dc:identifier.uri","label":"Identifier URI","values":["https://hdl.handle.net/10217/234093"],"render_values":[{"text":"https://hdl.handle.net/10217/234093","href":"https://hdl.handle.net/10217/234093","code":true}]}],"person_identifier_entries":[]},"links":{"outbound_url":"https://doi.org/10.25675/3.025171","outbound_label":"DOI","outbound_source":"dc:identifier.uri","record_url":"https://doi.org/10.25675/3.025171","record_label":"Repository record","record_kind":"doi","record_source":"dc:identifier.uri","access_status":null,"embargo_until":null,"access_note":null},"oai_pmh_record":{"url":"https://union.ndltd.org/oai-pmh/?verb=GetRecord&metadataPrefix=oai_dc&identifier=oai%3Aunion.ndltd.org%3Arepo%3Acolostate%3Aoai%3Amountainscholar.org%3A10217%2F234093","prefix":"oai_dc"},"source_record":{"url":"https://api.mountainscholar.org/server/oai/request?verb=GetRecord&metadataPrefix=dim&identifier=oai%3Amountainscholar.org%3A10217%2F234093","prefix":"dim"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:creator","label":"Author","values":["Steppuhn, Harold Wolfgang, author","Meiman, James R. (James Richard), advisor","Dils, Robert E., committee member","Harris, David V., committee member","Johnson, Gestur, 1910-, committee member","Duke, Harold R. (Harold Ray), 1940-, committee member"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2021-12-07T02:44:02Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2021-12-07T02:44:02Z"]},{"key":"dc:date.issued","label":"Date","values":["1970"]},{"key":"dc:publisher","label":"Institution","values":["Colorado State University. Libraries"]},{"key":"dc:relation","label":"Dc Relation","values":["MMS ID: 991004407599703361","GB1225.C6 S7"]},{"key":"dc:relation.ispartof","label":"Dc Relation Ispartof","values":["1950-1979"]},{"key":"dc:relation.isreferencedby","label":"Dc Relation Isreferencedby","values":["Meiman, James R. Little South Poudre Watershed and Pingree Park Campus. Colorado State University, College of Forestry and Natural Resources (1971). http://hdl.handle.net/10217/70382"]},{"key":"dc:type","label":"Dc Type","values":["Text"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Watershed Sciences"]},{"key":"thesis:degree_level","label":"Degree Level","values":["Doctoral"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Doctor of Philosophy (Ph.D.)"]},{"key":"thesis:institution_name","label":"Thesis Institution Name","values":["Colorado State University"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Stream measurements -- Colorado","Fluorimetry"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language","label":"Dc Language","values":["English"]},{"key":"dc:language.iso","label":"Language (ISO)","values":["eng"]},{"key":"dc:rights","label":"Dc Rights","values":["Copyright and other restrictions may apply. User is responsible for compliance with all applicable laws. For information about copyright law, please see https://libguides.colostate.edu/copyright.","This Item is protected by copyright and/or related rights (https://rightsstatements.org/vocab/InC/1.0/). You are free to use this Item in any way that is permitted by the copyright and related rights legislation that applies to your use. For other uses you need to obtain permission from the rights-holder(s)."]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.uri","label":"Identifier URI","values":["https://hdl.handle.net/10217/234093","https://doi.org/10.25675/3.025171"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description","label":"Description","values":["Covers not scanned. Item deaccessioned after digitization."]},{"key":"dc:description.abstract","label":"Abstract","values":["A system is developed capable of continuously monitoring the relative concentration of a fluorescent tracer in streamflow. Streamside instrumentation automatically registers stream-borne tracer concentrations as a function of time on a gelatin-coated film. The film is routed through a device which passes a continuous sample-aliquot diverted from the tracer-dosed stream over a small segment of the film. The \"exposed\" film is periodically gathered from stream sites and analyzed in a laboratory-based fluorometer. Utility of the system is studied for the gaging of streamflow to produce a hydrograph, to measure stream discharge instantaneously, and to determine time-of-stream-travel. Hydrographs resulting from 640 hours of gaging two Colorado mountain streams with the system are compared to those obtained from closely located sharp-crested weirs. The maximum instantaneous deviation between hydrographs reaches 10% and average absolute departure equals 1.8%, while algebraic departure averages +0.3%. The practicality of using this system to obtain time-of-stream travels is demonstrated for five Colorado mountain streams. A total of 62 traveling tracer-clouds are registered on gelatin-coated film, from which time-of-stream-travels are determined. Processes involved in the system and factors affecting its precision are investigated. Theoretical and experimental evidence strongly indicates that the bulk of tracer uptake by gelatin follows processes that are physical rather than chemical in nature. Stream temperature changes and duration of film-tracer contact are the two most important factors affecting precision of the system. Neither major factor caused any unsolvable problem when field operations were standardized. The system will have utility in operations where an expensive, temperature-sensitive fluorometer can not be stationed stream-side, and where the particular objectives of stream measurements do not justify the cost of conventional techniques, but where fair accuracy and continuous records of short to moderate duration are desired."]},{"key":"dc:format.medium","label":"Dc Format Medium","values":["doctoral dissertations"]},{"key":"dc:title","label":"Title","values":["A system for detecting fluorescent tracers in streamflow"]},{"key":"others:access_status","label":"Others Access Status","values":["open.access"]}]}],"canonical_facts":{"dc:creator":["Steppuhn, Harold Wolfgang, author","Meiman, James R. (James Richard), advisor","Dils, Robert E., committee member","Harris, David V., committee member","Johnson, Gestur, 1910-, committee member","Duke, Harold R. (Harold Ray), 1940-, committee member"],"dc:date.accessioned":["2021-12-07T02:44:02Z"],"dc:date.available":["2021-12-07T02:44:02Z"],"dc:date.issued":["1970"],"dc:description":["Covers not scanned. Item deaccessioned after digitization."],"dc:description.abstract":["A system is developed capable of continuously monitoring the relative concentration of a fluorescent tracer in streamflow. Streamside instrumentation automatically registers stream-borne tracer concentrations as a function of time on a gelatin-coated film. The film is routed through a device which passes a continuous sample-aliquot diverted from the tracer-dosed stream over a small segment of the film. The \"exposed\" film is periodically gathered from stream sites and analyzed in a laboratory-based fluorometer. Utility of the system is studied for the gaging of streamflow to produce a hydrograph, to measure stream discharge instantaneously, and to determine time-of-stream-travel. Hydrographs resulting from 640 hours of gaging two Colorado mountain streams with the system are compared to those obtained from closely located sharp-crested weirs. The maximum instantaneous deviation between hydrographs reaches 10% and average absolute departure equals 1.8%, while algebraic departure averages +0.3%. The practicality of using this system to obtain time-of-stream travels is demonstrated for five Colorado mountain streams. A total of 62 traveling tracer-clouds are registered on gelatin-coated film, from which time-of-stream-travels are determined. Processes involved in the system and factors affecting its precision are investigated. Theoretical and experimental evidence strongly indicates that the bulk of tracer uptake by gelatin follows processes that are physical rather than chemical in nature. Stream temperature changes and duration of film-tracer contact are the two most important factors affecting precision of the system. Neither major factor caused any unsolvable problem when field operations were standardized. The system will have utility in operations where an expensive, temperature-sensitive fluorometer can not be stationed stream-side, and where the particular objectives of stream measurements do not justify the cost of conventional techniques, but where fair accuracy and continuous records of short to moderate duration are desired."],"dc:format.medium":["doctoral dissertations"],"dc:identifier.uri":["https://hdl.handle.net/10217/234093","https://doi.org/10.25675/3.025171"],"dc:language":["English"],"dc:language.iso":["eng"],"dc:publisher":["Colorado State University. Libraries"],"dc:relation":["MMS ID: 991004407599703361","GB1225.C6 S7"],"dc:relation.ispartof":["1950-1979"],"dc:relation.isreferencedby":["Meiman, James R. Little South Poudre Watershed and Pingree Park Campus. Colorado State University, College of Forestry and Natural Resources (1971). http://hdl.handle.net/10217/70382"],"dc:rights":["Copyright and other restrictions may apply. User is responsible for compliance with all applicable laws. For information about copyright law, please see https://libguides.colostate.edu/copyright.","This Item is protected by copyright and/or related rights (https://rightsstatements.org/vocab/InC/1.0/). You are free to use this Item in any way that is permitted by the copyright and related rights legislation that applies to your use. For other uses you need to obtain permission from the rights-holder(s)."],"dc:subject":["Stream measurements -- Colorado","Fluorimetry"],"dc:title":["A system for detecting fluorescent tracers in streamflow"],"dc:type":["Text"],"others:access_status":["open.access"],"thesis:degree_discipline":["Watershed Sciences"],"thesis:degree_level":["Doctoral"],"thesis:degree_name":["Doctor of Philosophy (Ph.D.)"],"thesis:institution_name":["Colorado State University"]},"updated_at":"2026-11-19T07:17:35Z"}