{"id":{"repo_id":"colostate","oai_identifier":"oai:mountainscholar.org:10217/236808"},"canonical_url":"https://search.ndltd.org/etd/colostate/oai:mountainscholar.org:10217/236808","repository":{"repo_id":"colostate","name":"Colorado State University","base_url":"https://api.mountainscholar.org/server/oai/request"},"display":{"title":"Characterization of mixed linear energy transfer environments utilizing tissue-equivalent proportional counters","abstract":"There is currently great interest in the biological impact of radiological space exposures due to manned space missions (e.g., moon) where astronauts will face the challenge of living on board spacecraft for long periods of time. Cosmic radiation of many types exists in space and creates a unique mixed linear energy transfer (LET) environment. A tissue equivalent proportional counter (TEPC) was used to produce dose-equivalent measurements and quantify neutron exposures. Three neutron sources were used to simulate high energy, mixed LET environments: californium-252, a plutonium-beryllium source, and a deuterium-tritium neutron generator. TEPC dose-equivalent measurements can be utilized for basic research, and regulatory or clinical purposes for correlation with observable health effects. The main study was to quantify and compare TEPC dose equivalent rates in microdosimetric volumes to determine if significant dosimetric differences exist between mixed LET environments generated by photons and neutrons. The findings from this experiment showed that mixed LET environments where both photons and neutrons interacted with the TEPC had lower average LET values than neutron-only exposures, and produced varying dose equivalent rates that were dependent on the source characteristics. In summary, the TEPC was capable of monitoring in a mixed-LET environment and was successful at measuring the absorbed dose of high-energy photon and neutron interactions in space-like settings.","abstract_html":"There is currently great interest in the biological impact of radiological space exposures due to manned space missions (e.g., moon) where astronauts will face the challenge of living on board spacecraft for long periods of time. Cosmic radiation of many types exists in space and creates a unique mixed linear energy transfer (LET) environment. A tissue equivalent proportional counter (TEPC) was used to produce dose-equivalent measurements and quantify neutron exposures. Three neutron sources were used to simulate high energy, mixed LET environments: californium-252, a plutonium-beryllium source, and a deuterium-tritium neutron generator. TEPC dose-equivalent measurements can be utilized for basic research, and regulatory or clinical purposes for correlation with observable health effects. The main study was to quantify and compare TEPC dose equivalent rates in microdosimetric volumes to determine if significant dosimetric differences exist between mixed LET environments generated by photons and neutrons. The findings from this experiment showed that mixed LET environments where both photons and neutrons interacted with the TEPC had lower average LET values than neutron-only exposures, and produced varying dose equivalent rates that were dependent on the source characteristics. In summary, the TEPC was capable of monitoring in a mixed-LET environment and was successful at measuring the absorbed dose of high-energy photon and neutron interactions in space-like settings.","abstract_has_math":false,"creators":["Fehrman, Joseph M., author","Brandl, Alexander, advisor","Johnson, Thomas, advisor","Carlson, Kenneth, committee member"],"institution":"Colorado State University. Libraries","degree_name":"Master of Science (M.S.)","degree_level":"Masters","degree_discipline":"Environmental and Radiological Health Sciences","degree_department":null,"school":null,"contributors":[],"advisors":[],"committee_chairs":[],"committee_members":[],"year":2023,"date_issued":"2023","date_published":"2023","updated_at":"2026-11-19T07:12:47Z","subjects":["linear energy transfer","neutrons","tissue-equivalent proportional counter","microdosimetry","absorbed dose","space radiation"],"languages":["eng","English"],"rights":["Copyright and other restrictions may apply. User is responsible for compliance with all applicable laws. For information about copyright law, please see https://libguides.colostate.edu/copyright.","This Item is protected by copyright and/or related rights (https://rightsstatements.org/vocab/InC/1.0/). You are free to use this Item in any way that is permitted by the copyright and related rights legislation that applies to your use. For other uses you need to obtain permission from the rights-holder(s)."],"rights_urls":[],"identifier_entries":[{"key":"dc:identifier.uri","label":"Identifier URI","values":["https://hdl.handle.net/10217/236808"],"render_values":[{"text":"https://hdl.handle.net/10217/236808","href":"https://hdl.handle.net/10217/236808","code":true}]},{"key":"dc:identifier","label":"Identifier","values":["Fehrman_colostate_0053N_17868.pdf"],"render_values":[{"text":"Fehrman_colostate_0053N_17868.pdf","href":null,"code":true}]}],"person_identifier_entries":[]},"links":{"outbound_url":"https://doi.org/10.25675/3.03776","outbound_label":"DOI","outbound_source":"dc:identifier.uri","record_url":"https://doi.org/10.25675/3.03776","record_label":"Repository record","record_kind":"doi","record_source":"dc:identifier.uri","access_status":null,"embargo_until":null,"access_note":null},"oai_pmh_record":{"url":"https://union.ndltd.org/oai-pmh/?verb=GetRecord&metadataPrefix=oai_dc&identifier=oai%3Aunion.ndltd.org%3Arepo%3Acolostate%3Aoai%3Amountainscholar.org%3A10217%2F236808","prefix":"oai_dc"},"source_record":{"url":"https://api.mountainscholar.org/server/oai/request?verb=GetRecord&metadataPrefix=dim&identifier=oai%3Amountainscholar.org%3A10217%2F236808","prefix":"dim"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:creator","label":"Author","values":["Fehrman, Joseph M., author","Brandl, Alexander, advisor","Johnson, Thomas, advisor","Carlson, Kenneth, committee member"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2023-08-28T10:27:50Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2023-08-28T10:27:50Z"]},{"key":"dc:date.issued","label":"Date","values":["2023"]},{"key":"dc:publisher","label":"Institution","values":["Colorado State University. Libraries"]},{"key":"dc:relation.ispartof","label":"Dc Relation Ispartof","values":["2020-"]},{"key":"dc:type","label":"Dc Type","values":["Text"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Environmental and Radiological Health Sciences"]},{"key":"thesis:degree_level","label":"Degree Level","values":["Masters"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Master of Science (M.S.)"]},{"key":"thesis:institution_name","label":"Thesis Institution Name","values":["Colorado State University"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["linear energy transfer","neutrons","tissue-equivalent proportional counter","microdosimetry","absorbed dose","space radiation"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language","label":"Dc Language","values":["English"]},{"key":"dc:language.iso","label":"Language (ISO)","values":["eng"]},{"key":"dc:rights","label":"Dc Rights","values":["Copyright and other restrictions may apply. User is responsible for compliance with all applicable laws. For information about copyright law, please see https://libguides.colostate.edu/copyright.","This Item is protected by copyright and/or related rights (https://rightsstatements.org/vocab/InC/1.0/). You are free to use this Item in any way that is permitted by the copyright and related rights legislation that applies to your use. For other uses you need to obtain permission from the rights-holder(s)."]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier","label":"Identifier","values":["Fehrman_colostate_0053N_17868.pdf"]},{"key":"dc:identifier.uri","label":"Identifier URI","values":["https://hdl.handle.net/10217/236808","https://doi.org/10.25675/3.03776"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["There is currently great interest in the biological impact of radiological space exposures due to manned space missions (e.g., moon) where astronauts will face the challenge of living on board spacecraft for long periods of time. Cosmic radiation of many types exists in space and creates a unique mixed linear energy transfer (LET) environment. A tissue equivalent proportional counter (TEPC) was used to produce dose-equivalent measurements and quantify neutron exposures. Three neutron sources were used to simulate high energy, mixed LET environments: californium-252, a plutonium-beryllium source, and a deuterium-tritium neutron generator. TEPC dose-equivalent measurements can be utilized for basic research, and regulatory or clinical purposes for correlation with observable health effects. The main study was to quantify and compare TEPC dose equivalent rates in microdosimetric volumes to determine if significant dosimetric differences exist between mixed LET environments generated by photons and neutrons. The findings from this experiment showed that mixed LET environments where both photons and neutrons interacted with the TEPC had lower average LET values than neutron-only exposures, and produced varying dose equivalent rates that were dependent on the source characteristics. In summary, the TEPC was capable of monitoring in a mixed-LET environment and was successful at measuring the absorbed dose of high-energy photon and neutron interactions in space-like settings."]},{"key":"dc:format.medium","label":"Dc Format Medium","values":["born digital","masters theses"]},{"key":"dc:title","label":"Title","values":["Characterization of mixed linear energy transfer environments utilizing tissue-equivalent proportional counters"]},{"key":"others:access_status","label":"Others Access Status","values":["open.access"]}]}],"canonical_facts":{"dc:creator":["Fehrman, Joseph M., author","Brandl, Alexander, advisor","Johnson, Thomas, advisor","Carlson, Kenneth, committee member"],"dc:date.accessioned":["2023-08-28T10:27:50Z"],"dc:date.available":["2023-08-28T10:27:50Z"],"dc:date.issued":["2023"],"dc:description.abstract":["There is currently great interest in the biological impact of radiological space exposures due to manned space missions (e.g., moon) where astronauts will face the challenge of living on board spacecraft for long periods of time. Cosmic radiation of many types exists in space and creates a unique mixed linear energy transfer (LET) environment. A tissue equivalent proportional counter (TEPC) was used to produce dose-equivalent measurements and quantify neutron exposures. Three neutron sources were used to simulate high energy, mixed LET environments: californium-252, a plutonium-beryllium source, and a deuterium-tritium neutron generator. TEPC dose-equivalent measurements can be utilized for basic research, and regulatory or clinical purposes for correlation with observable health effects. The main study was to quantify and compare TEPC dose equivalent rates in microdosimetric volumes to determine if significant dosimetric differences exist between mixed LET environments generated by photons and neutrons. The findings from this experiment showed that mixed LET environments where both photons and neutrons interacted with the TEPC had lower average LET values than neutron-only exposures, and produced varying dose equivalent rates that were dependent on the source characteristics. In summary, the TEPC was capable of monitoring in a mixed-LET environment and was successful at measuring the absorbed dose of high-energy photon and neutron interactions in space-like settings."],"dc:format.medium":["born digital","masters theses"],"dc:identifier":["Fehrman_colostate_0053N_17868.pdf"],"dc:identifier.uri":["https://hdl.handle.net/10217/236808","https://doi.org/10.25675/3.03776"],"dc:language":["English"],"dc:language.iso":["eng"],"dc:publisher":["Colorado State University. Libraries"],"dc:relation.ispartof":["2020-"],"dc:rights":["Copyright and other restrictions may apply. User is responsible for compliance with all applicable laws. For information about copyright law, please see https://libguides.colostate.edu/copyright.","This Item is protected by copyright and/or related rights (https://rightsstatements.org/vocab/InC/1.0/). You are free to use this Item in any way that is permitted by the copyright and related rights legislation that applies to your use. For other uses you need to obtain permission from the rights-holder(s)."],"dc:subject":["linear energy transfer","neutrons","tissue-equivalent proportional counter","microdosimetry","absorbed dose","space radiation"],"dc:title":["Characterization of mixed linear energy transfer environments utilizing tissue-equivalent proportional counters"],"dc:type":["Text"],"others:access_status":["open.access"],"thesis:degree_discipline":["Environmental and Radiological Health Sciences"],"thesis:degree_level":["Masters"],"thesis:degree_name":["Master of Science (M.S.)"],"thesis:institution_name":["Colorado State University"]},"updated_at":"2026-11-19T07:12:47Z"}