{"id":{"repo_id":"colostate","oai_identifier":"oai:mountainscholar.org:10217/237733"},"canonical_url":"https://search.ndltd.org/etd/colostate/oai:mountainscholar.org:10217/237733","repository":{"repo_id":"colostate","name":"Colorado State University","base_url":"https://api.mountainscholar.org/server/oai/request"},"display":{"title":"The ongoing development of the technique of two-beam fluorescence cross-correlation spectroscopy coupled with continuous-flow capillary electrophoresis","abstract":"This thesis describes work performed in the development and application of the technique of two-beam fluorescence cross-correlation spectroscopy coupled with continuous-flow capillary electrophoresis (2bFCCS-CFCE). In this approach, fluorescently-labeled molecules of interest are monitored as they electrophoretically migrate in continuous solution between two, spatially-separated laser foci. The work presented here illustrates a number of advantages that 2bFCCS-CFCE analysis has over more conventional capillary electrophoresis (CE) techniques. Three sets of experiments were performed that illustrate these advantages. In the first set of experiments, 2bFCCS-CFCE was used to detect and discriminate between three different analyte molecules electrophoretically migrating in opposite directions. The ability of 2bFCCS-CFCE to monitor molecules electrophoretically migrating in opposite directions without the need of sample injection steps or multiple buffers demonstrated a distinct advantage over conventional CE techniques, which require complex buffer conditions, sample injection, and can only analyze species migrating in uniform direction. The second set of experiments demonstrated 2bFCCS-CFCE on microchip platforms (2bFCCS-CFMCCE). Several design advantages of 2bFCCS-CFMCCE relative to separations-based CE microchip platforms, such as increased miniaturization and simpler fluid handling format, were demonstrated. The third set of experiments demonstrated the ability of 2bFCCS-CFCE to measure the effective charge of a single-stranded DNA (ssDNA) in the presence of magnesium ions. The measurement of effective charge requires analysis of both diffusion and electrophoretic migration simultaneously. Conventional CE experiments are not capable of making this measurement. 2bFCCS-CFCE was used to successfully measure the effective charge, revealing the interesting relationship between ssDNA charge and size.","abstract_html":"This thesis describes work performed in the development and application of the technique of two-beam fluorescence cross-correlation spectroscopy coupled with continuous-flow capillary electrophoresis (2bFCCS-CFCE). In this approach, fluorescently-labeled molecules of interest are monitored as they electrophoretically migrate in continuous solution between two, spatially-separated laser foci. The work presented here illustrates a number of advantages that 2bFCCS-CFCE analysis has over more conventional capillary electrophoresis (CE) techniques. Three sets of experiments were performed that illustrate these advantages. In the first set of experiments, 2bFCCS-CFCE was used to detect and discriminate between three different analyte molecules electrophoretically migrating in opposite directions. The ability of 2bFCCS-CFCE to monitor molecules electrophoretically migrating in opposite directions without the need of sample injection steps or multiple buffers demonstrated a distinct advantage over conventional CE techniques, which require complex buffer conditions, sample injection, and can only analyze species migrating in uniform direction. The second set of experiments demonstrated 2bFCCS-CFCE on microchip platforms (2bFCCS-CFMCCE). Several design advantages of 2bFCCS-CFMCCE relative to separations-based CE microchip platforms, such as increased miniaturization and simpler fluid handling format, were demonstrated. The third set of experiments demonstrated the ability of 2bFCCS-CFCE to measure the effective charge of a single-stranded DNA (ssDNA) in the presence of magnesium ions. The measurement of effective charge requires analysis of both diffusion and electrophoretic migration simultaneously. Conventional CE experiments are not capable of making this measurement. 2bFCCS-CFCE was used to successfully measure the effective charge, revealing the interesting relationship between ssDNA charge and size.","abstract_has_math":false,"creators":["Fogarty, Keir, author","Van Orden, Alan K., advisor"],"institution":"Colorado State University. Libraries","degree_name":"Doctor of Philosophy (Ph.D.)","degree_level":"Doctoral","degree_discipline":"Chemistry","degree_department":null,"school":null,"contributors":[],"advisors":[],"committee_chairs":[],"committee_members":[],"year":2008,"date_issued":"2008","date_published":"2008","updated_at":"2026-11-19T07:13:28Z","subjects":["capillary electrophoresis","correlation spectroscopy","DNA diffusion","fluorescence cross-correlation spectroscopy","microchip capillary electrophoresis","single-molecule spectroscopy","analytical chemistry","biophysics"],"languages":["eng","English"],"rights":["Copyright and other restrictions may apply. User is responsible for compliance with all applicable laws. For information about copyright law, please see https://libguides.colostate.edu/copyright.","This Item is protected by copyright and/or related rights (https://rightsstatements.org/vocab/InC/1.0/). You are free to use this Item in any way that is permitted by the copyright and related rights legislation that applies to your use. For other uses you need to obtain permission from the rights-holder(s)."],"rights_urls":[],"identifier_entries":[{"key":"dc:identifier.uri","label":"Identifier URI","values":["https://hdl.handle.net/10217/237733"],"render_values":[{"text":"https://hdl.handle.net/10217/237733","href":"https://hdl.handle.net/10217/237733","code":true}]},{"key":"dc:identifier","label":"Identifier","values":["ETDF_Fogarty_2008_3321277.pdf"],"render_values":[{"text":"ETDF_Fogarty_2008_3321277.pdf","href":null,"code":true}]}],"person_identifier_entries":[]},"links":{"outbound_url":"https://doi.org/10.25675/3.022340","outbound_label":"DOI","outbound_source":"dc:identifier.uri","record_url":"https://doi.org/10.25675/3.022340","record_label":"Repository record","record_kind":"doi","record_source":"dc:identifier.uri","access_status":null,"embargo_until":null,"access_note":null},"oai_pmh_record":{"url":"https://union.ndltd.org/oai-pmh/?verb=GetRecord&metadataPrefix=oai_dc&identifier=oai%3Aunion.ndltd.org%3Arepo%3Acolostate%3Aoai%3Amountainscholar.org%3A10217%2F237733","prefix":"oai_dc"},"source_record":{"url":"https://api.mountainscholar.org/server/oai/request?verb=GetRecord&metadataPrefix=dim&identifier=oai%3Amountainscholar.org%3A10217%2F237733","prefix":"dim"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:creator","label":"Author","values":["Fogarty, Keir, author","Van Orden, Alan K., advisor"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2024-03-13T19:26:17Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2024-03-13T19:26:17Z"]},{"key":"dc:date.issued","label":"Date","values":["2008"]},{"key":"dc:publisher","label":"Institution","values":["Colorado State University. Libraries"]},{"key":"dc:relation.ispartof","label":"Dc Relation Ispartof","values":["2000-2019"]},{"key":"dc:type","label":"Dc Type","values":["Text"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Chemistry"]},{"key":"thesis:degree_level","label":"Degree Level","values":["Doctoral"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Doctor of Philosophy (Ph.D.)"]},{"key":"thesis:institution_name","label":"Thesis Institution Name","values":["Colorado State University"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["capillary electrophoresis","correlation spectroscopy","DNA diffusion","fluorescence cross-correlation spectroscopy","microchip capillary electrophoresis","single-molecule spectroscopy","analytical chemistry","biophysics"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language","label":"Dc Language","values":["English"]},{"key":"dc:language.iso","label":"Language (ISO)","values":["eng"]},{"key":"dc:rights","label":"Dc Rights","values":["Copyright and other restrictions may apply. User is responsible for compliance with all applicable laws. For information about copyright law, please see https://libguides.colostate.edu/copyright.","This Item is protected by copyright and/or related rights (https://rightsstatements.org/vocab/InC/1.0/). You are free to use this Item in any way that is permitted by the copyright and related rights legislation that applies to your use. For other uses you need to obtain permission from the rights-holder(s)."]},{"key":"dc:rights.license","label":"Dc Rights License","values":["Per the terms of a contractual agreement, all use of this item is limited to the non-commercial use of Colorado State University and its authorized users."]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier","label":"Identifier","values":["ETDF_Fogarty_2008_3321277.pdf"]},{"key":"dc:identifier.uri","label":"Identifier URI","values":["https://hdl.handle.net/10217/237733","https://doi.org/10.25675/3.022340"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description","label":"Description","values":["Not digitized by CSUL Digital Services."]},{"key":"dc:description.abstract","label":"Abstract","values":["This thesis describes work performed in the development and application of the technique of two-beam fluorescence cross-correlation spectroscopy coupled with continuous-flow capillary electrophoresis (2bFCCS-CFCE). In this approach, fluorescently-labeled molecules of interest are monitored as they electrophoretically migrate in continuous solution between two, spatially-separated laser foci. The work presented here illustrates a number of advantages that 2bFCCS-CFCE analysis has over more conventional capillary electrophoresis (CE) techniques. Three sets of experiments were performed that illustrate these advantages. In the first set of experiments, 2bFCCS-CFCE was used to detect and discriminate between three different analyte molecules electrophoretically migrating in opposite directions. The ability of 2bFCCS-CFCE to monitor molecules electrophoretically migrating in opposite directions without the need of sample injection steps or multiple buffers demonstrated a distinct advantage over conventional CE techniques, which require complex buffer conditions, sample injection, and can only analyze species migrating in uniform direction. The second set of experiments demonstrated 2bFCCS-CFCE on microchip platforms (2bFCCS-CFMCCE). Several design advantages of 2bFCCS-CFMCCE relative to separations-based CE microchip platforms, such as increased miniaturization and simpler fluid handling format, were demonstrated. The third set of experiments demonstrated the ability of 2bFCCS-CFCE to measure the effective charge of a single-stranded DNA (ssDNA) in the presence of magnesium ions. The measurement of effective charge requires analysis of both diffusion and electrophoretic migration simultaneously. Conventional CE experiments are not capable of making this measurement. 2bFCCS-CFCE was used to successfully measure the effective charge, revealing the interesting relationship between ssDNA charge and size."]},{"key":"dc:format.medium","label":"Dc Format Medium","values":["doctoral dissertations"]},{"key":"dc:title","label":"Title","values":["The ongoing development of the technique of two-beam fluorescence cross-correlation spectroscopy coupled with continuous-flow capillary electrophoresis"]},{"key":"others:access_status","label":"Others Access Status","values":["open.access"]}]}],"canonical_facts":{"dc:creator":["Fogarty, Keir, author","Van Orden, Alan K., advisor"],"dc:date.accessioned":["2024-03-13T19:26:17Z"],"dc:date.available":["2024-03-13T19:26:17Z"],"dc:date.issued":["2008"],"dc:description":["Not digitized by CSUL Digital Services."],"dc:description.abstract":["This thesis describes work performed in the development and application of the technique of two-beam fluorescence cross-correlation spectroscopy coupled with continuous-flow capillary electrophoresis (2bFCCS-CFCE). In this approach, fluorescently-labeled molecules of interest are monitored as they electrophoretically migrate in continuous solution between two, spatially-separated laser foci. The work presented here illustrates a number of advantages that 2bFCCS-CFCE analysis has over more conventional capillary electrophoresis (CE) techniques. Three sets of experiments were performed that illustrate these advantages. In the first set of experiments, 2bFCCS-CFCE was used to detect and discriminate between three different analyte molecules electrophoretically migrating in opposite directions. The ability of 2bFCCS-CFCE to monitor molecules electrophoretically migrating in opposite directions without the need of sample injection steps or multiple buffers demonstrated a distinct advantage over conventional CE techniques, which require complex buffer conditions, sample injection, and can only analyze species migrating in uniform direction. The second set of experiments demonstrated 2bFCCS-CFCE on microchip platforms (2bFCCS-CFMCCE). Several design advantages of 2bFCCS-CFMCCE relative to separations-based CE microchip platforms, such as increased miniaturization and simpler fluid handling format, were demonstrated. The third set of experiments demonstrated the ability of 2bFCCS-CFCE to measure the effective charge of a single-stranded DNA (ssDNA) in the presence of magnesium ions. The measurement of effective charge requires analysis of both diffusion and electrophoretic migration simultaneously. Conventional CE experiments are not capable of making this measurement. 2bFCCS-CFCE was used to successfully measure the effective charge, revealing the interesting relationship between ssDNA charge and size."],"dc:format.medium":["doctoral dissertations"],"dc:identifier":["ETDF_Fogarty_2008_3321277.pdf"],"dc:identifier.uri":["https://hdl.handle.net/10217/237733","https://doi.org/10.25675/3.022340"],"dc:language":["English"],"dc:language.iso":["eng"],"dc:publisher":["Colorado State University. Libraries"],"dc:relation.ispartof":["2000-2019"],"dc:rights":["Copyright and other restrictions may apply. User is responsible for compliance with all applicable laws. For information about copyright law, please see https://libguides.colostate.edu/copyright.","This Item is protected by copyright and/or related rights (https://rightsstatements.org/vocab/InC/1.0/). You are free to use this Item in any way that is permitted by the copyright and related rights legislation that applies to your use. For other uses you need to obtain permission from the rights-holder(s)."],"dc:rights.license":["Per the terms of a contractual agreement, all use of this item is limited to the non-commercial use of Colorado State University and its authorized users."],"dc:subject":["capillary electrophoresis","correlation spectroscopy","DNA diffusion","fluorescence cross-correlation spectroscopy","microchip capillary electrophoresis","single-molecule spectroscopy","analytical chemistry","biophysics"],"dc:title":["The ongoing development of the technique of two-beam fluorescence cross-correlation spectroscopy coupled with continuous-flow capillary electrophoresis"],"dc:type":["Text"],"others:access_status":["open.access"],"thesis:degree_discipline":["Chemistry"],"thesis:degree_level":["Doctoral"],"thesis:degree_name":["Doctor of Philosophy (Ph.D.)"],"thesis:institution_name":["Colorado State University"]},"updated_at":"2026-11-19T07:13:28Z"}