{"id":{"repo_id":"colostate","oai_identifier":"oai:mountainscholar.org:10217/237844"},"canonical_url":"https://search.ndltd.org/etd/colostate/oai:mountainscholar.org:10217/237844","repository":{"repo_id":"colostate","name":"Colorado State University","base_url":"https://api.mountainscholar.org/server/oai/request"},"display":{"title":"Comparison of occupational and environmental exposures at Colorado dairies","abstract":"Occupational contaminant levels and environmental emissions were compared at two Colorado dairies. Along with meteorological conditions, analytes measured included odor, hydrogen sulfide, ammonia, total and inhalable particulate and endotoxin, and bioaerosols including fungi, mesophilic bacteria, and gram-negative bacteria. Meteorologic conditions varied widely in temperature (range: -12.5 - 4 1.1°C), relative humidity (range: 0.6 - 92.3%) and wind speeds during sampling (range: 0.48 - 8.66 m/s). Geometric mean bioaerosol concentrations for the Anderson sampler and SKC Biosampler include: mesophilic bacteria, 1282 and 383 CFU/m3, gram-negative bacteria, 667 and 265 CFU/m 3, and fungi, 781 and 252 CFU/m3. The Anderson sampler collected significantly (p<0.001) higher bioaerosol concentrations for all three categories. Peak ammonia levels at the study and control dairies ranged from 2.0 - 142 and 2.0 - 23 ppm. Peak ammonia was significantly (p<0.05) higher at the study dairy. Mean hydrogen sulfide levels at the study and control dairies ranged from 4.0 - 394 and 4.0 - 890 ppb. Peak hydrogen sulfide levels at the study and control dairies ranged from 37 - 17,000 and 210 - 5,200 ppb. Mean peak hydrogen sulfide was significantly (p<0.05) higher at the control dairy. Odor measures ranged from 0-15 D/T at both dairies. Inhalable particulate at study and control dairy lagoons ranged from < LOD - 2.3 mg/m3. Inhalable endotoxin at study and control dairy lagoons ranged from 2.1 - 487.2 EU/m3. Total particulate at study and control dairy lagoons ranged from < LOD to 2.4 mg/m3. Total endotoxin at study and control lagoons ranged from 2.5 - 6587 EU/m3. Inhalable particulate for tasks at both dairies ranged from 0.06 - 8.0 mg/m3. Total particulate for tasks at both dairies ranged from 0.03 - 6.9 mg/m 3. Inhalable endotoxin for tasks at both dairies ranged from 2.0 - 11096 EU/m3. Total endotoxin for tasks at both dairies ranged from 5.9 - 6758 EU/m3. Supported by NIOSH Grant 5U500H008085.","abstract_html":"Occupational contaminant levels and environmental emissions were compared at two Colorado dairies. Along with meteorological conditions, analytes measured included odor, hydrogen sulfide, ammonia, total and inhalable particulate and endotoxin, and bioaerosols including fungi, mesophilic bacteria, and gram-negative bacteria. Meteorologic conditions varied widely in temperature (range: -12.5 - 4 1.1°C), relative humidity (range: 0.6 - 92.3%) and wind speeds during sampling (range: 0.48 - 8.66 m/s). Geometric mean bioaerosol concentrations for the Anderson sampler and SKC Biosampler include: mesophilic bacteria, 1282 and 383 CFU/m3, gram-negative bacteria, 667 and 265 CFU/m 3, and fungi, 781 and 252 CFU/m3. The Anderson sampler collected significantly (p&lt;0.001) higher bioaerosol concentrations for all three categories. Peak ammonia levels at the study and control dairies ranged from 2.0 - 142 and 2.0 - 23 ppm. Peak ammonia was significantly (p&lt;0.05) higher at the study dairy. Mean hydrogen sulfide levels at the study and control dairies ranged from 4.0 - 394 and 4.0 - 890 ppb. Peak hydrogen sulfide levels at the study and control dairies ranged from 37 - 17,000 and 210 - 5,200 ppb. Mean peak hydrogen sulfide was significantly (p&lt;0.05) higher at the control dairy. Odor measures ranged from 0-15 D/T at both dairies. Inhalable particulate at study and control dairy lagoons ranged from &lt; LOD - 2.3 mg/m3. Inhalable endotoxin at study and control dairy lagoons ranged from 2.1 - 487.2 EU/m3. Total particulate at study and control dairy lagoons ranged from &lt; LOD to 2.4 mg/m3. Total endotoxin at study and control lagoons ranged from 2.5 - 6587 EU/m3. Inhalable particulate for tasks at both dairies ranged from 0.06 - 8.0 mg/m3. Total particulate for tasks at both dairies ranged from 0.03 - 6.9 mg/m 3. Inhalable endotoxin for tasks at both dairies ranged from 2.0 - 11096 EU/m3. Total endotoxin for tasks at both dairies ranged from 5.9 - 6758 EU/m3. Supported by NIOSH Grant 5U500H008085.","abstract_has_math":false,"creators":["Lester, Bradley Raymond, author","Reynolds, Stephen J., advisor"],"institution":"Colorado State University. Libraries","degree_name":"Doctor of Philosophy (Ph.D.)","degree_level":"Doctoral","degree_discipline":"Environmental and Radiological Health Sciences","degree_department":null,"school":null,"contributors":[],"advisors":[],"committee_chairs":[],"committee_members":[],"year":2008,"date_issued":"2008","date_published":"2008","updated_at":"2026-11-19T07:13:37Z","subjects":["agriculture","Colorado","dairies","emissions","environmental exposure","hydrogen sulfide","occupational exposure","odor"],"languages":["eng","English"],"rights":["Copyright and other restrictions may apply. User is responsible for compliance with all applicable laws. For information about copyright law, please see https://libguides.colostate.edu/copyright.","This Item is protected by copyright and/or related rights (https://rightsstatements.org/vocab/InC/1.0/). You are free to use this Item in any way that is permitted by the copyright and related rights legislation that applies to your use. For other uses you need to obtain permission from the rights-holder(s)."],"rights_urls":[],"identifier_entries":[{"key":"dc:identifier.uri","label":"Identifier URI","values":["https://hdl.handle.net/10217/237844"],"render_values":[{"text":"https://hdl.handle.net/10217/237844","href":"https://hdl.handle.net/10217/237844","code":true}]},{"key":"dc:identifier","label":"Identifier","values":["ETDF_Lester_2008_3321292.pdf"],"render_values":[{"text":"ETDF_Lester_2008_3321292.pdf","href":null,"code":true}]}],"person_identifier_entries":[]},"links":{"outbound_url":"https://doi.org/10.25675/3.022453","outbound_label":"DOI","outbound_source":"dc:identifier.uri","record_url":"https://doi.org/10.25675/3.022453","record_label":"Repository record","record_kind":"doi","record_source":"dc:identifier.uri","access_status":null,"embargo_until":null,"access_note":null},"oai_pmh_record":{"url":"https://union.ndltd.org/oai-pmh/?verb=GetRecord&metadataPrefix=oai_dc&identifier=oai%3Aunion.ndltd.org%3Arepo%3Acolostate%3Aoai%3Amountainscholar.org%3A10217%2F237844","prefix":"oai_dc"},"source_record":{"url":"https://api.mountainscholar.org/server/oai/request?verb=GetRecord&metadataPrefix=dim&identifier=oai%3Amountainscholar.org%3A10217%2F237844","prefix":"dim"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:creator","label":"Author","values":["Lester, Bradley Raymond, author","Reynolds, Stephen J., advisor"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2024-03-13T20:12:23Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2024-03-13T20:12:23Z"]},{"key":"dc:date.issued","label":"Date","values":["2008"]},{"key":"dc:publisher","label":"Institution","values":["Colorado State University. Libraries"]},{"key":"dc:relation.ispartof","label":"Dc Relation Ispartof","values":["2000-2019"]},{"key":"dc:type","label":"Dc Type","values":["Text"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Environmental and Radiological Health Sciences"]},{"key":"thesis:degree_level","label":"Degree Level","values":["Doctoral"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Doctor of Philosophy (Ph.D.)"]},{"key":"thesis:institution_name","label":"Thesis Institution Name","values":["Colorado State University"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["agriculture","Colorado","dairies","emissions","environmental exposure","hydrogen sulfide","occupational exposure","odor"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language","label":"Dc Language","values":["English"]},{"key":"dc:language.iso","label":"Language (ISO)","values":["eng"]},{"key":"dc:rights","label":"Dc Rights","values":["Copyright and other restrictions may apply. User is responsible for compliance with all applicable laws. For information about copyright law, please see https://libguides.colostate.edu/copyright.","This Item is protected by copyright and/or related rights (https://rightsstatements.org/vocab/InC/1.0/). You are free to use this Item in any way that is permitted by the copyright and related rights legislation that applies to your use. For other uses you need to obtain permission from the rights-holder(s)."]},{"key":"dc:rights.license","label":"Dc Rights License","values":["Per the terms of a contractual agreement, all use of this item is limited to the non-commercial use of Colorado State University and its authorized users."]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier","label":"Identifier","values":["ETDF_Lester_2008_3321292.pdf"]},{"key":"dc:identifier.uri","label":"Identifier URI","values":["https://hdl.handle.net/10217/237844","https://doi.org/10.25675/3.022453"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description","label":"Description","values":["Not digitized by CSUL Digital Services."]},{"key":"dc:description.abstract","label":"Abstract","values":["Occupational contaminant levels and environmental emissions were compared at two Colorado dairies. Along with meteorological conditions, analytes measured included odor, hydrogen sulfide, ammonia, total and inhalable particulate and endotoxin, and bioaerosols including fungi, mesophilic bacteria, and gram-negative bacteria. Meteorologic conditions varied widely in temperature (range: -12.5 - 4 1.1°C), relative humidity (range: 0.6 - 92.3%) and wind speeds during sampling (range: 0.48 - 8.66 m/s). Geometric mean bioaerosol concentrations for the Anderson sampler and SKC Biosampler include: mesophilic bacteria, 1282 and 383 CFU/m3, gram-negative bacteria, 667 and 265 CFU/m 3, and fungi, 781 and 252 CFU/m3. The Anderson sampler collected significantly (p<0.001) higher bioaerosol concentrations for all three categories. Peak ammonia levels at the study and control dairies ranged from 2.0 - 142 and 2.0 - 23 ppm. Peak ammonia was significantly (p<0.05) higher at the study dairy. Mean hydrogen sulfide levels at the study and control dairies ranged from 4.0 - 394 and 4.0 - 890 ppb. Peak hydrogen sulfide levels at the study and control dairies ranged from 37 - 17,000 and 210 - 5,200 ppb. Mean peak hydrogen sulfide was significantly (p<0.05) higher at the control dairy. Odor measures ranged from 0-15 D/T at both dairies. Inhalable particulate at study and control dairy lagoons ranged from < LOD - 2.3 mg/m3. Inhalable endotoxin at study and control dairy lagoons ranged from 2.1 - 487.2 EU/m3. Total particulate at study and control dairy lagoons ranged from < LOD to 2.4 mg/m3. Total endotoxin at study and control lagoons ranged from 2.5 - 6587 EU/m3. Inhalable particulate for tasks at both dairies ranged from 0.06 - 8.0 mg/m3. Total particulate for tasks at both dairies ranged from 0.03 - 6.9 mg/m 3. Inhalable endotoxin for tasks at both dairies ranged from 2.0 - 11096 EU/m3. Total endotoxin for tasks at both dairies ranged from 5.9 - 6758 EU/m3. Supported by NIOSH Grant 5U500H008085."]},{"key":"dc:format.medium","label":"Dc Format Medium","values":["doctoral dissertations"]},{"key":"dc:title","label":"Title","values":["Comparison of occupational and environmental exposures at Colorado dairies"]},{"key":"others:access_status","label":"Others Access Status","values":["open.access"]}]}],"canonical_facts":{"dc:creator":["Lester, Bradley Raymond, author","Reynolds, Stephen J., advisor"],"dc:date.accessioned":["2024-03-13T20:12:23Z"],"dc:date.available":["2024-03-13T20:12:23Z"],"dc:date.issued":["2008"],"dc:description":["Not digitized by CSUL Digital Services."],"dc:description.abstract":["Occupational contaminant levels and environmental emissions were compared at two Colorado dairies. Along with meteorological conditions, analytes measured included odor, hydrogen sulfide, ammonia, total and inhalable particulate and endotoxin, and bioaerosols including fungi, mesophilic bacteria, and gram-negative bacteria. Meteorologic conditions varied widely in temperature (range: -12.5 - 4 1.1°C), relative humidity (range: 0.6 - 92.3%) and wind speeds during sampling (range: 0.48 - 8.66 m/s). Geometric mean bioaerosol concentrations for the Anderson sampler and SKC Biosampler include: mesophilic bacteria, 1282 and 383 CFU/m3, gram-negative bacteria, 667 and 265 CFU/m 3, and fungi, 781 and 252 CFU/m3. The Anderson sampler collected significantly (p<0.001) higher bioaerosol concentrations for all three categories. Peak ammonia levels at the study and control dairies ranged from 2.0 - 142 and 2.0 - 23 ppm. Peak ammonia was significantly (p<0.05) higher at the study dairy. Mean hydrogen sulfide levels at the study and control dairies ranged from 4.0 - 394 and 4.0 - 890 ppb. Peak hydrogen sulfide levels at the study and control dairies ranged from 37 - 17,000 and 210 - 5,200 ppb. Mean peak hydrogen sulfide was significantly (p<0.05) higher at the control dairy. Odor measures ranged from 0-15 D/T at both dairies. Inhalable particulate at study and control dairy lagoons ranged from < LOD - 2.3 mg/m3. Inhalable endotoxin at study and control dairy lagoons ranged from 2.1 - 487.2 EU/m3. Total particulate at study and control dairy lagoons ranged from < LOD to 2.4 mg/m3. Total endotoxin at study and control lagoons ranged from 2.5 - 6587 EU/m3. Inhalable particulate for tasks at both dairies ranged from 0.06 - 8.0 mg/m3. Total particulate for tasks at both dairies ranged from 0.03 - 6.9 mg/m 3. Inhalable endotoxin for tasks at both dairies ranged from 2.0 - 11096 EU/m3. Total endotoxin for tasks at both dairies ranged from 5.9 - 6758 EU/m3. Supported by NIOSH Grant 5U500H008085."],"dc:format.medium":["doctoral dissertations"],"dc:identifier":["ETDF_Lester_2008_3321292.pdf"],"dc:identifier.uri":["https://hdl.handle.net/10217/237844","https://doi.org/10.25675/3.022453"],"dc:language":["English"],"dc:language.iso":["eng"],"dc:publisher":["Colorado State University. Libraries"],"dc:relation.ispartof":["2000-2019"],"dc:rights":["Copyright and other restrictions may apply. User is responsible for compliance with all applicable laws. For information about copyright law, please see https://libguides.colostate.edu/copyright.","This Item is protected by copyright and/or related rights (https://rightsstatements.org/vocab/InC/1.0/). You are free to use this Item in any way that is permitted by the copyright and related rights legislation that applies to your use. For other uses you need to obtain permission from the rights-holder(s)."],"dc:rights.license":["Per the terms of a contractual agreement, all use of this item is limited to the non-commercial use of Colorado State University and its authorized users."],"dc:subject":["agriculture","Colorado","dairies","emissions","environmental exposure","hydrogen sulfide","occupational exposure","odor"],"dc:title":["Comparison of occupational and environmental exposures at Colorado dairies"],"dc:type":["Text"],"others:access_status":["open.access"],"thesis:degree_discipline":["Environmental and Radiological Health Sciences"],"thesis:degree_level":["Doctoral"],"thesis:degree_name":["Doctor of Philosophy (Ph.D.)"],"thesis:institution_name":["Colorado State University"]},"updated_at":"2026-11-19T07:13:37Z"}