{"id":{"repo_id":"colostate","oai_identifier":"oai:mountainscholar.org:10217/243002"},"canonical_url":"https://search.ndltd.org/etd/colostate/oai:mountainscholar.org:10217/243002","repository":{"repo_id":"colostate","name":"Colorado State University","base_url":"https://api.mountainscholar.org/server/oai/request"},"display":{"title":"Response of a tissue equivalent proportional counter to different ions having a similar linear energy transfer","abstract":"The Tissue Equivalent Proportional Counter (TEPC) is a part of the active dosimetry of current space missions, measuring high-energy charged particles making up the proton and galactic cosmic radiation (GCR) fields, as well as the fragmentation products produced when these radiations interact with shielding. It is also used to characterize high-energy charged particle beams produced by accelerators used at many tumor treatment facilities throughout the world. A proper understanding of its response to these types of radiation fields is required before an assessment of radiation quality and dose equivalent may be made with confidence. Past studies have characterized detector response to a single high-energy ion, 56Fe, with energies ranging from 200 to 1,000 MeV/nucleon. It was found that the TEPC could be used to accurately determine the average quality of high-energy charged particles, and therefore dose equivalent, if the dose mean lineal energy, yd, were used. The present study is an analysis of TEPC response to several high-energy ions having different charge and velocity, the square of their ratio, Z2/V2, chosen such that all ions have a similar Linear Energy Transfer (LET). Four ions, 14N, 16O, 20Ne and 28Si, all having an LET of about 43 keV/?m were measured at the Heavy Ion Medical Accelerator (HIMAC) in Chiba, Japan with a spherical TEPC having a physical diameter of 1.27 cm. Results of this study indicate that the proper choice of using yf or yd to determine radiation quality and absorbed dose may depend on the associated momentum of the ion.","abstract_html":"The Tissue Equivalent Proportional Counter (TEPC) is a part of the active dosimetry of current space missions, measuring high-energy charged particles making up the proton and galactic cosmic radiation (GCR) fields, as well as the fragmentation products produced when these radiations interact with shielding. It is also used to characterize high-energy charged particle beams produced by accelerators used at many tumor treatment facilities throughout the world. A proper understanding of its response to these types of radiation fields is required before an assessment of radiation quality and dose equivalent may be made with confidence. Past studies have characterized detector response to a single high-energy ion, 56Fe, with energies ranging from 200 to 1,000 MeV/nucleon. It was found that the TEPC could be used to accurately determine the average quality of high-energy charged particles, and therefore dose equivalent, if the dose mean lineal energy, yd, were used. The present study is an analysis of TEPC response to several high-energy ions having different charge and velocity, the square of their ratio, Z2/V2, chosen such that all ions have a similar Linear Energy Transfer (LET). Four ions, 14N, 16O, 20Ne and 28Si, all having an LET of about 43 keV/?m were measured at the Heavy Ion Medical Accelerator (HIMAC) in Chiba, Japan with a spherical TEPC having a physical diameter of 1.27 cm. Results of this study indicate that the proper choice of using yf or yd to determine radiation quality and absorbed dose may depend on the associated momentum of the ion.","abstract_has_math":false,"creators":["Guetersloh, Stephen Brant, author","Borak, Thomas B., author","Iyer, Hariharan, committee member","Zeitlin, Cary, committee member","Ullrich, Robert, committee member"],"institution":"Colorado State University. Libraries","degree_name":"Doctor of Philosophy (Ph.D.)","degree_level":"Doctoral","degree_discipline":"Environmental and Radiological Health Sciences","degree_department":null,"school":null,"contributors":[],"advisors":[],"committee_chairs":[],"committee_members":[],"year":2003,"date_issued":"2003","date_published":"2003","updated_at":"2026-11-19T07:09:22Z","subjects":["radiation","biophysics","nuclear physics"],"languages":["eng","English"],"rights":["Copyright and other restrictions may apply. User is responsible for compliance with all applicable laws. For information about copyright law, please see https://libguides.colostate.edu/copyright.","This Item is protected by copyright and/or related rights (https://rightsstatements.org/vocab/InC/1.0/). You are free to use this Item in any way that is permitted by the copyright and related rights legislation that applies to your use. For other uses you need to obtain permission from the rights-holder(s)."],"rights_urls":[],"identifier_entries":[{"key":"dc:identifier.uri","label":"Identifier URI","values":["https://hdl.handle.net/10217/243002"],"render_values":[{"text":"https://hdl.handle.net/10217/243002","href":"https://hdl.handle.net/10217/243002","code":true}]}],"person_identifier_entries":[]},"links":{"outbound_url":"https://doi.org/10.25675/3.025858","outbound_label":"DOI","outbound_source":"dc:identifier.uri","record_url":"https://doi.org/10.25675/3.025858","record_label":"Repository record","record_kind":"doi","record_source":"dc:identifier.uri","access_status":null,"embargo_until":null,"access_note":null},"oai_pmh_record":{"url":"https://union.ndltd.org/oai-pmh/?verb=GetRecord&metadataPrefix=oai_dc&identifier=oai%3Aunion.ndltd.org%3Arepo%3Acolostate%3Aoai%3Amountainscholar.org%3A10217%2F243002","prefix":"oai_dc"},"source_record":{"url":"https://api.mountainscholar.org/server/oai/request?verb=GetRecord&metadataPrefix=dim&identifier=oai%3Amountainscholar.org%3A10217%2F243002","prefix":"dim"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:creator","label":"Author","values":["Guetersloh, Stephen Brant, author","Borak, Thomas B., author","Iyer, Hariharan, committee member","Zeitlin, Cary, committee member","Ullrich, Robert, committee member"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2026-01-29T19:31:21Z"]},{"key":"dc:date.issued","label":"Date","values":["2003"]},{"key":"dc:publisher","label":"Institution","values":["Colorado State University. Libraries"]},{"key":"dc:relation.ispartof","label":"Dc Relation Ispartof","values":["2000-2019"]},{"key":"dc:type","label":"Dc Type","values":["Text"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Environmental and Radiological Health Sciences"]},{"key":"thesis:degree_level","label":"Degree Level","values":["Doctoral"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Doctor of Philosophy (Ph.D.)"]},{"key":"thesis:institution_name","label":"Thesis Institution Name","values":["Colorado State University"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["radiation","biophysics","nuclear physics"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language","label":"Dc Language","values":["English"]},{"key":"dc:language.iso","label":"Language (ISO)","values":["eng"]},{"key":"dc:rights","label":"Dc Rights","values":["Copyright and other restrictions may apply. User is responsible for compliance with all applicable laws. For information about copyright law, please see https://libguides.colostate.edu/copyright.","This Item is protected by copyright and/or related rights (https://rightsstatements.org/vocab/InC/1.0/). You are free to use this Item in any way that is permitted by the copyright and related rights legislation that applies to your use. For other uses you need to obtain permission from the rights-holder(s)."]},{"key":"dc:rights.license","label":"Dc Rights License","values":["Per the terms of a contractual agreement, all use of this item is limited to the non-commercial use of Colorado State University and its authorized users."]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.uri","label":"Identifier URI","values":["https://hdl.handle.net/10217/243002","https://doi.org/10.25675/3.025858"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description","label":"Description","values":["Not digitized by CSUL Digital Services."]},{"key":"dc:description.abstract","label":"Abstract","values":["The Tissue Equivalent Proportional Counter (TEPC) is a part of the active dosimetry of current space missions, measuring high-energy charged particles making up the proton and galactic cosmic radiation (GCR) fields, as well as the fragmentation products produced when these radiations interact with shielding. It is also used to characterize high-energy charged particle beams produced by accelerators used at many tumor treatment facilities throughout the world. A proper understanding of its response to these types of radiation fields is required before an assessment of radiation quality and dose equivalent may be made with confidence. Past studies have characterized detector response to a single high-energy ion, 56Fe, with energies ranging from 200 to 1,000 MeV/nucleon. It was found that the TEPC could be used to accurately determine the average quality of high-energy charged particles, and therefore dose equivalent, if the dose mean lineal energy, yd, were used. The present study is an analysis of TEPC response to several high-energy ions having different charge and velocity, the square of their ratio, Z2/V2, chosen such that all ions have a similar Linear Energy Transfer (LET). Four ions, 14N, 16O, 20Ne and 28Si, all having an LET of about 43 keV/?m were measured at the Heavy Ion Medical Accelerator (HIMAC) in Chiba, Japan with a spherical TEPC having a physical diameter of 1.27 cm. Results of this study indicate that the proper choice of using yf or yd to determine radiation quality and absorbed dose may depend on the associated momentum of the ion."]},{"key":"dc:format.medium","label":"Dc Format Medium","values":["doctoral dissertations"]},{"key":"dc:title","label":"Title","values":["Response of a tissue equivalent proportional counter to different ions having a similar linear energy transfer"]},{"key":"others:access_status","label":"Others Access Status","values":["open.access"]}]}],"canonical_facts":{"dc:creator":["Guetersloh, Stephen Brant, author","Borak, Thomas B., author","Iyer, Hariharan, committee member","Zeitlin, Cary, committee member","Ullrich, Robert, committee member"],"dc:date.accessioned":["2026-01-29T19:31:21Z"],"dc:date.issued":["2003"],"dc:description":["Not digitized by CSUL Digital Services."],"dc:description.abstract":["The Tissue Equivalent Proportional Counter (TEPC) is a part of the active dosimetry of current space missions, measuring high-energy charged particles making up the proton and galactic cosmic radiation (GCR) fields, as well as the fragmentation products produced when these radiations interact with shielding. It is also used to characterize high-energy charged particle beams produced by accelerators used at many tumor treatment facilities throughout the world. A proper understanding of its response to these types of radiation fields is required before an assessment of radiation quality and dose equivalent may be made with confidence. Past studies have characterized detector response to a single high-energy ion, 56Fe, with energies ranging from 200 to 1,000 MeV/nucleon. It was found that the TEPC could be used to accurately determine the average quality of high-energy charged particles, and therefore dose equivalent, if the dose mean lineal energy, yd, were used. The present study is an analysis of TEPC response to several high-energy ions having different charge and velocity, the square of their ratio, Z2/V2, chosen such that all ions have a similar Linear Energy Transfer (LET). Four ions, 14N, 16O, 20Ne and 28Si, all having an LET of about 43 keV/?m were measured at the Heavy Ion Medical Accelerator (HIMAC) in Chiba, Japan with a spherical TEPC having a physical diameter of 1.27 cm. Results of this study indicate that the proper choice of using yf or yd to determine radiation quality and absorbed dose may depend on the associated momentum of the ion."],"dc:format.medium":["doctoral dissertations"],"dc:identifier.uri":["https://hdl.handle.net/10217/243002","https://doi.org/10.25675/3.025858"],"dc:language":["English"],"dc:language.iso":["eng"],"dc:publisher":["Colorado State University. Libraries"],"dc:relation.ispartof":["2000-2019"],"dc:rights":["Copyright and other restrictions may apply. User is responsible for compliance with all applicable laws. For information about copyright law, please see https://libguides.colostate.edu/copyright.","This Item is protected by copyright and/or related rights (https://rightsstatements.org/vocab/InC/1.0/). You are free to use this Item in any way that is permitted by the copyright and related rights legislation that applies to your use. For other uses you need to obtain permission from the rights-holder(s)."],"dc:rights.license":["Per the terms of a contractual agreement, all use of this item is limited to the non-commercial use of Colorado State University and its authorized users."],"dc:subject":["radiation","biophysics","nuclear physics"],"dc:title":["Response of a tissue equivalent proportional counter to different ions having a similar linear energy transfer"],"dc:type":["Text"],"others:access_status":["open.access"],"thesis:degree_discipline":["Environmental and Radiological Health Sciences"],"thesis:degree_level":["Doctoral"],"thesis:degree_name":["Doctor of Philosophy (Ph.D.)"],"thesis:institution_name":["Colorado State University"]},"updated_at":"2026-11-19T07:09:22Z"}