{"id":{"repo_id":"colostate","oai_identifier":"oai:mountainscholar.org:10217/243142"},"canonical_url":"https://search.ndltd.org/etd/colostate/oai:mountainscholar.org:10217/243142","repository":{"repo_id":"colostate","name":"Colorado State University","base_url":"https://api.mountainscholar.org/server/oai/request"},"display":{"title":"Utilizing routine water quality instruments for monitoring distribution system security","abstract":"Drinking water system security concerns have been a considerable issue in the United States in recent years, but in the last two years this issue has risen to new levels of urgency. The tragic events of September 11th highlighted America's vulnerability to terrorism and spurred a domestic security response unprecedented since World War II. Currently, significant purposeful contamination of a water system won't be properly characterized until post-symptomatic epidemiological events are manifested in the affected community. One approach to mitigating this potential disaster includes on-line monitoring of drinking water distribution systems. Four credible threat chemical drinking water contaminants (aldicarb, sodium arsenate, sodium cyanide, and sodium fluoroacetate) were analyzed at different concentrations to determine their detectability in a drinking water distribution system using commonly measured parameters. On-line monitoring that measured conductivity, pH, chlorine residual, turbidity, and total organic carbon was completed to determine baseline water quality indicators. The contaminants were then mixed with tap water and analyzed in beakers to determine their contaminant instrument response at various concentrations with bench top instruments. This data was then used to determine dosing into a bench scale distribution system. The contaminants were then added at the specified concentrations to determine detectability using the online monitoring equipment. Results indicate that the four chemical contaminants can be detected at relatively low concentrations with routine monitoring. Three of the four chemical contaminants can be detected below a concentration that will cause significant health impacts. When these same contaminants were introduced into an acclimated bioreactor, it was determined that toxicity induced sloughing off of biomass increased the turbidity response significantly, effectively lowering the limit of detection for the chemical contaminants. To ensure that the increase in turbidity was a result of toxicity induced sloughing off of biomass, cell counts were conducted on the biofilm containing PVC coupons using fluorescence microscopy. It was shown that indeed cell counts were significantly reduced after introduction of the contaminants. Multivariate cluster analysis of the data also demonstrated a potential to reduce the time to detect a contamination event versus univariate analysis.","abstract_html":"Drinking water system security concerns have been a considerable issue in the United States in recent years, but in the last two years this issue has risen to new levels of urgency. The tragic events of September 11th highlighted America&#x27;s vulnerability to terrorism and spurred a domestic security response unprecedented since World War II. Currently, significant purposeful contamination of a water system won&#x27;t be properly characterized until post-symptomatic epidemiological events are manifested in the affected community. One approach to mitigating this potential disaster includes on-line monitoring of drinking water distribution systems. Four credible threat chemical drinking water contaminants (aldicarb, sodium arsenate, sodium cyanide, and sodium fluoroacetate) were analyzed at different concentrations to determine their detectability in a drinking water distribution system using commonly measured parameters. On-line monitoring that measured conductivity, pH, chlorine residual, turbidity, and total organic carbon was completed to determine baseline water quality indicators. The contaminants were then mixed with tap water and analyzed in beakers to determine their contaminant instrument response at various concentrations with bench top instruments. This data was then used to determine dosing into a bench scale distribution system. The contaminants were then added at the specified concentrations to determine detectability using the online monitoring equipment. Results indicate that the four chemical contaminants can be detected at relatively low concentrations with routine monitoring. Three of the four chemical contaminants can be detected below a concentration that will cause significant health impacts. When these same contaminants were introduced into an acclimated bioreactor, it was determined that toxicity induced sloughing off of biomass increased the turbidity response significantly, effectively lowering the limit of detection for the chemical contaminants. To ensure that the increase in turbidity was a result of toxicity induced sloughing off of biomass, cell counts were conducted on the biofilm containing PVC coupons using fluorescence microscopy. It was shown that indeed cell counts were significantly reduced after introduction of the contaminants. Multivariate cluster analysis of the data also demonstrated a potential to reduce the time to detect a contamination event versus univariate analysis.","abstract_has_math":false,"creators":["Byer, David E., author","Carlson, Ken, advisor","Anderson, Chuck, committee member","Grigg, Neil, committee member","Roesner, Larry, committee member"],"institution":"Colorado State University. Libraries","degree_name":"Doctor of Philosophy (Ph.D.)","degree_level":"Doctoral","degree_discipline":"Civil Engineering","degree_department":null,"school":null,"contributors":[],"advisors":[],"committee_chairs":[],"committee_members":[],"year":2004,"date_issued":"2004","date_published":"2004","updated_at":"2026-11-19T07:12:40Z","subjects":["environmental engineering","sanitation"],"languages":["eng","English"],"rights":["Copyright and other restrictions may apply. User is responsible for compliance with all applicable laws. For information about copyright law, please see https://libguides.colostate.edu/copyright.","This Item is protected by copyright and/or related rights (https://rightsstatements.org/vocab/InC/1.0/). You are free to use this Item in any way that is permitted by the copyright and related rights legislation that applies to your use. For other uses you need to obtain permission from the rights-holder(s)."],"rights_urls":[],"identifier_entries":[{"key":"dc:identifier.uri","label":"Identifier URI","values":["https://hdl.handle.net/10217/243142"],"render_values":[{"text":"https://hdl.handle.net/10217/243142","href":"https://hdl.handle.net/10217/243142","code":true}]}],"person_identifier_entries":[]},"links":{"outbound_url":"https://doi.org/10.25675/3.025996","outbound_label":"DOI","outbound_source":"dc:identifier.uri","record_url":"https://doi.org/10.25675/3.025996","record_label":"Repository record","record_kind":"doi","record_source":"dc:identifier.uri","access_status":null,"embargo_until":null,"access_note":null},"oai_pmh_record":{"url":"https://union.ndltd.org/oai-pmh/?verb=GetRecord&metadataPrefix=oai_dc&identifier=oai%3Aunion.ndltd.org%3Arepo%3Acolostate%3Aoai%3Amountainscholar.org%3A10217%2F243142","prefix":"oai_dc"},"source_record":{"url":"https://api.mountainscholar.org/server/oai/request?verb=GetRecord&metadataPrefix=dim&identifier=oai%3Amountainscholar.org%3A10217%2F243142","prefix":"dim"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:creator","label":"Author","values":["Byer, David E., author","Carlson, Ken, advisor","Anderson, Chuck, committee member","Grigg, Neil, committee member","Roesner, Larry, committee member"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2026-02-09T19:25:14Z"]},{"key":"dc:date.issued","label":"Date","values":["2004"]},{"key":"dc:publisher","label":"Institution","values":["Colorado State University. Libraries"]},{"key":"dc:relation.ispartof","label":"Dc Relation Ispartof","values":["2000-2019"]},{"key":"dc:type","label":"Dc Type","values":["Text"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Civil Engineering"]},{"key":"thesis:degree_level","label":"Degree Level","values":["Doctoral"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Doctor of Philosophy (Ph.D.)"]},{"key":"thesis:institution_name","label":"Thesis Institution Name","values":["Colorado State University"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["environmental engineering","sanitation"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language","label":"Dc Language","values":["English"]},{"key":"dc:language.iso","label":"Language (ISO)","values":["eng"]},{"key":"dc:rights","label":"Dc Rights","values":["Copyright and other restrictions may apply. User is responsible for compliance with all applicable laws. For information about copyright law, please see https://libguides.colostate.edu/copyright.","This Item is protected by copyright and/or related rights (https://rightsstatements.org/vocab/InC/1.0/). You are free to use this Item in any way that is permitted by the copyright and related rights legislation that applies to your use. For other uses you need to obtain permission from the rights-holder(s)."]},{"key":"dc:rights.license","label":"Dc Rights License","values":["Per the terms of a contractual agreement, all use of this item is limited to the non-commercial use of Colorado State University and its authorized users."]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.uri","label":"Identifier URI","values":["https://hdl.handle.net/10217/243142","https://doi.org/10.25675/3.025996"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description","label":"Description","values":["Not digitized by CSUL Digital Services."]},{"key":"dc:description.abstract","label":"Abstract","values":["Drinking water system security concerns have been a considerable issue in the United States in recent years, but in the last two years this issue has risen to new levels of urgency. The tragic events of September 11th highlighted America's vulnerability to terrorism and spurred a domestic security response unprecedented since World War II. Currently, significant purposeful contamination of a water system won't be properly characterized until post-symptomatic epidemiological events are manifested in the affected community. One approach to mitigating this potential disaster includes on-line monitoring of drinking water distribution systems. Four credible threat chemical drinking water contaminants (aldicarb, sodium arsenate, sodium cyanide, and sodium fluoroacetate) were analyzed at different concentrations to determine their detectability in a drinking water distribution system using commonly measured parameters. On-line monitoring that measured conductivity, pH, chlorine residual, turbidity, and total organic carbon was completed to determine baseline water quality indicators. The contaminants were then mixed with tap water and analyzed in beakers to determine their contaminant instrument response at various concentrations with bench top instruments. This data was then used to determine dosing into a bench scale distribution system. The contaminants were then added at the specified concentrations to determine detectability using the online monitoring equipment. Results indicate that the four chemical contaminants can be detected at relatively low concentrations with routine monitoring. Three of the four chemical contaminants can be detected below a concentration that will cause significant health impacts. When these same contaminants were introduced into an acclimated bioreactor, it was determined that toxicity induced sloughing off of biomass increased the turbidity response significantly, effectively lowering the limit of detection for the chemical contaminants. To ensure that the increase in turbidity was a result of toxicity induced sloughing off of biomass, cell counts were conducted on the biofilm containing PVC coupons using fluorescence microscopy. It was shown that indeed cell counts were significantly reduced after introduction of the contaminants. Multivariate cluster analysis of the data also demonstrated a potential to reduce the time to detect a contamination event versus univariate analysis."]},{"key":"dc:format.medium","label":"Dc Format Medium","values":["doctoral dissertations"]},{"key":"dc:title","label":"Title","values":["Utilizing routine water quality instruments for monitoring distribution system security"]},{"key":"others:access_status","label":"Others Access Status","values":["open.access"]}]}],"canonical_facts":{"dc:creator":["Byer, David E., author","Carlson, Ken, advisor","Anderson, Chuck, committee member","Grigg, Neil, committee member","Roesner, Larry, committee member"],"dc:date.accessioned":["2026-02-09T19:25:14Z"],"dc:date.issued":["2004"],"dc:description":["Not digitized by CSUL Digital Services."],"dc:description.abstract":["Drinking water system security concerns have been a considerable issue in the United States in recent years, but in the last two years this issue has risen to new levels of urgency. The tragic events of September 11th highlighted America's vulnerability to terrorism and spurred a domestic security response unprecedented since World War II. Currently, significant purposeful contamination of a water system won't be properly characterized until post-symptomatic epidemiological events are manifested in the affected community. One approach to mitigating this potential disaster includes on-line monitoring of drinking water distribution systems. Four credible threat chemical drinking water contaminants (aldicarb, sodium arsenate, sodium cyanide, and sodium fluoroacetate) were analyzed at different concentrations to determine their detectability in a drinking water distribution system using commonly measured parameters. On-line monitoring that measured conductivity, pH, chlorine residual, turbidity, and total organic carbon was completed to determine baseline water quality indicators. The contaminants were then mixed with tap water and analyzed in beakers to determine their contaminant instrument response at various concentrations with bench top instruments. This data was then used to determine dosing into a bench scale distribution system. The contaminants were then added at the specified concentrations to determine detectability using the online monitoring equipment. Results indicate that the four chemical contaminants can be detected at relatively low concentrations with routine monitoring. Three of the four chemical contaminants can be detected below a concentration that will cause significant health impacts. When these same contaminants were introduced into an acclimated bioreactor, it was determined that toxicity induced sloughing off of biomass increased the turbidity response significantly, effectively lowering the limit of detection for the chemical contaminants. To ensure that the increase in turbidity was a result of toxicity induced sloughing off of biomass, cell counts were conducted on the biofilm containing PVC coupons using fluorescence microscopy. It was shown that indeed cell counts were significantly reduced after introduction of the contaminants. Multivariate cluster analysis of the data also demonstrated a potential to reduce the time to detect a contamination event versus univariate analysis."],"dc:format.medium":["doctoral dissertations"],"dc:identifier.uri":["https://hdl.handle.net/10217/243142","https://doi.org/10.25675/3.025996"],"dc:language":["English"],"dc:language.iso":["eng"],"dc:publisher":["Colorado State University. Libraries"],"dc:relation.ispartof":["2000-2019"],"dc:rights":["Copyright and other restrictions may apply. User is responsible for compliance with all applicable laws. For information about copyright law, please see https://libguides.colostate.edu/copyright.","This Item is protected by copyright and/or related rights (https://rightsstatements.org/vocab/InC/1.0/). You are free to use this Item in any way that is permitted by the copyright and related rights legislation that applies to your use. For other uses you need to obtain permission from the rights-holder(s)."],"dc:rights.license":["Per the terms of a contractual agreement, all use of this item is limited to the non-commercial use of Colorado State University and its authorized users."],"dc:subject":["environmental engineering","sanitation"],"dc:title":["Utilizing routine water quality instruments for monitoring distribution system security"],"dc:type":["Text"],"others:access_status":["open.access"],"thesis:degree_discipline":["Civil Engineering"],"thesis:degree_level":["Doctoral"],"thesis:degree_name":["Doctor of Philosophy (Ph.D.)"],"thesis:institution_name":["Colorado State University"]},"updated_at":"2026-11-19T07:12:40Z"}