{"id":{"repo_id":"colostate","oai_identifier":"oai:mountainscholar.org:10217/243719"},"canonical_url":"https://search.ndltd.org/etd/colostate/oai:mountainscholar.org:10217/243719","repository":{"repo_id":"colostate","name":"Colorado State University","base_url":"https://api.mountainscholar.org/server/oai/request"},"display":{"title":"The response of a spherical tissue-equivalent proportional counter to iron particles from 200-1000 MeV/nucleon","abstract":"The radiation environment aboard the space shuttle and the International Space Station includes high-Z and high-energy (HZE) particles that are part of the galactic cosmic radiation (GCR) spectrum. The 56Fe ion is considered to be one of the most biologically important parts of the GCR spectrum. Tissue-equivalent proportional counters (TEPC) are used as active dosimeters on manned space flights. These TEPC's are further used to determine average quality factor for each space mission. A TEPC simulating a 1-μm diameter sphere of tissue was exposed as part of a particle spectrometer to 56Fe at energies from 200-1000 MeV/nucleon. The response of TEPC in terms of mean lineal energy ӯF, and dose mean lineal energy, ӯD, as well as energy deposited at different impact parameters through detector was determined for six different incident energies of 56Fe in this energy range. Calculations determined that charged particle equilibrium was achieved for each of the six experiments. Energy depositions at different impact parameters were calculated using the spatially restricted LET model, a radial dose distribution model. Energy deposition at one impact parameter (0-mm) was calculated with a track structure model code called BTC4. Results from these three model calculations were compared to experimental data.","abstract_html":"The radiation environment aboard the space shuttle and the International Space Station includes high-Z and high-energy (HZE) particles that are part of the galactic cosmic radiation (GCR) spectrum. The 56Fe ion is considered to be one of the most biologically important parts of the GCR spectrum. Tissue-equivalent proportional counters (TEPC) are used as active dosimeters on manned space flights. These TEPC&#x27;s are further used to determine average quality factor for each space mission. A TEPC simulating a 1-μm diameter sphere of tissue was exposed as part of a particle spectrometer to 56Fe at energies from 200-1000 MeV/nucleon. The response of TEPC in terms of mean lineal energy ӯF, and dose mean lineal energy, ӯD, as well as energy deposited at different impact parameters through detector was determined for six different incident energies of 56Fe in this energy range. Calculations determined that charged particle equilibrium was achieved for each of the six experiments. Energy depositions at different impact parameters were calculated using the spatially restricted LET model, a radial dose distribution model. Energy deposition at one impact parameter (0-mm) was calculated with a track structure model code called BTC4. Results from these three model calculations were compared to experimental data.","abstract_has_math":false,"creators":["Gersey, Brad B., author","Borak, Thomas B., advisor","Blakely, Eleanor A., committee member","Harton, John L., committee member","Zimbrick, John D., committee member"],"institution":"Colorado State University. Libraries","degree_name":"Doctor of Philosophy (Ph.D.)","degree_level":"Doctoral","degree_discipline":"Environmental and Radiological Health Sciences","degree_department":null,"school":null,"contributors":[],"advisors":[],"committee_chairs":[],"committee_members":[],"year":2006,"date_issued":"2006","date_published":"2006","updated_at":"2026-11-19T07:13:00Z","subjects":["radiation","nuclear physics"],"languages":["eng","English"],"rights":["Copyright and other restrictions may apply. User is responsible for compliance with all applicable laws. For information about copyright law, please see https://libguides.colostate.edu/copyright.","This Item is protected by copyright and/or related rights (https://rightsstatements.org/vocab/InC/1.0/). You are free to use this Item in any way that is permitted by the copyright and related rights legislation that applies to your use. For other uses you need to obtain permission from the rights-holder(s)."],"rights_urls":[],"identifier_entries":[{"key":"dc:identifier.uri","label":"Identifier URI","values":["https://hdl.handle.net/10217/243719"],"render_values":[{"text":"https://hdl.handle.net/10217/243719","href":"https://hdl.handle.net/10217/243719","code":true}]}],"person_identifier_entries":[]},"links":{"outbound_url":"https://doi.org/10.25675/3.026439","outbound_label":"DOI","outbound_source":"dc:identifier.uri","record_url":"https://doi.org/10.25675/3.026439","record_label":"Repository record","record_kind":"doi","record_source":"dc:identifier.uri","access_status":null,"embargo_until":null,"access_note":null},"oai_pmh_record":{"url":"https://union.ndltd.org/oai-pmh/?verb=GetRecord&metadataPrefix=oai_dc&identifier=oai%3Aunion.ndltd.org%3Arepo%3Acolostate%3Aoai%3Amountainscholar.org%3A10217%2F243719","prefix":"oai_dc"},"source_record":{"url":"https://api.mountainscholar.org/server/oai/request?verb=GetRecord&metadataPrefix=dim&identifier=oai%3Amountainscholar.org%3A10217%2F243719","prefix":"dim"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:creator","label":"Author","values":["Gersey, Brad B., author","Borak, Thomas B., advisor","Blakely, Eleanor A., committee member","Harton, John L., committee member","Zimbrick, John D., committee member"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2026-03-16T18:25:11Z"]},{"key":"dc:date.issued","label":"Date","values":["2006"]},{"key":"dc:publisher","label":"Institution","values":["Colorado State University. Libraries"]},{"key":"dc:relation.ispartof","label":"Dc Relation Ispartof","values":["2000-2019"]},{"key":"dc:type","label":"Dc Type","values":["Text"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Environmental and Radiological Health Sciences"]},{"key":"thesis:degree_level","label":"Degree Level","values":["Doctoral"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Doctor of Philosophy (Ph.D.)"]},{"key":"thesis:institution_name","label":"Thesis Institution Name","values":["Colorado State University"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["radiation","nuclear physics"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language","label":"Dc Language","values":["English"]},{"key":"dc:language.iso","label":"Language (ISO)","values":["eng"]},{"key":"dc:rights","label":"Dc Rights","values":["Copyright and other restrictions may apply. User is responsible for compliance with all applicable laws. For information about copyright law, please see https://libguides.colostate.edu/copyright.","This Item is protected by copyright and/or related rights (https://rightsstatements.org/vocab/InC/1.0/). You are free to use this Item in any way that is permitted by the copyright and related rights legislation that applies to your use. For other uses you need to obtain permission from the rights-holder(s)."]},{"key":"dc:rights.license","label":"Dc Rights License","values":["Per the terms of a contractual agreement, all use of this item is limited to the non-commercial use of Colorado State University and its authorized users."]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.uri","label":"Identifier URI","values":["https://hdl.handle.net/10217/243719","https://doi.org/10.25675/3.026439"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description","label":"Description","values":["Not digitized by CSUL Digital Services."]},{"key":"dc:description.abstract","label":"Abstract","values":["The radiation environment aboard the space shuttle and the International Space Station includes high-Z and high-energy (HZE) particles that are part of the galactic cosmic radiation (GCR) spectrum. The 56Fe ion is considered to be one of the most biologically important parts of the GCR spectrum. Tissue-equivalent proportional counters (TEPC) are used as active dosimeters on manned space flights. These TEPC's are further used to determine average quality factor for each space mission. A TEPC simulating a 1-μm diameter sphere of tissue was exposed as part of a particle spectrometer to 56Fe at energies from 200-1000 MeV/nucleon. The response of TEPC in terms of mean lineal energy ӯF, and dose mean lineal energy, ӯD, as well as energy deposited at different impact parameters through detector was determined for six different incident energies of 56Fe in this energy range. Calculations determined that charged particle equilibrium was achieved for each of the six experiments. Energy depositions at different impact parameters were calculated using the spatially restricted LET model, a radial dose distribution model. Energy deposition at one impact parameter (0-mm) was calculated with a track structure model code called BTC4. Results from these three model calculations were compared to experimental data."]},{"key":"dc:format.medium","label":"Dc Format Medium","values":["doctoral dissertations"]},{"key":"dc:title","label":"Title","values":["The response of a spherical tissue-equivalent proportional counter to iron particles from 200-1000 MeV/nucleon"]},{"key":"others:access_status","label":"Others Access Status","values":["open.access"]}]}],"canonical_facts":{"dc:creator":["Gersey, Brad B., author","Borak, Thomas B., advisor","Blakely, Eleanor A., committee member","Harton, John L., committee member","Zimbrick, John D., committee member"],"dc:date.accessioned":["2026-03-16T18:25:11Z"],"dc:date.issued":["2006"],"dc:description":["Not digitized by CSUL Digital Services."],"dc:description.abstract":["The radiation environment aboard the space shuttle and the International Space Station includes high-Z and high-energy (HZE) particles that are part of the galactic cosmic radiation (GCR) spectrum. The 56Fe ion is considered to be one of the most biologically important parts of the GCR spectrum. Tissue-equivalent proportional counters (TEPC) are used as active dosimeters on manned space flights. These TEPC's are further used to determine average quality factor for each space mission. A TEPC simulating a 1-μm diameter sphere of tissue was exposed as part of a particle spectrometer to 56Fe at energies from 200-1000 MeV/nucleon. The response of TEPC in terms of mean lineal energy ӯF, and dose mean lineal energy, ӯD, as well as energy deposited at different impact parameters through detector was determined for six different incident energies of 56Fe in this energy range. Calculations determined that charged particle equilibrium was achieved for each of the six experiments. Energy depositions at different impact parameters were calculated using the spatially restricted LET model, a radial dose distribution model. Energy deposition at one impact parameter (0-mm) was calculated with a track structure model code called BTC4. Results from these three model calculations were compared to experimental data."],"dc:format.medium":["doctoral dissertations"],"dc:identifier.uri":["https://hdl.handle.net/10217/243719","https://doi.org/10.25675/3.026439"],"dc:language":["English"],"dc:language.iso":["eng"],"dc:publisher":["Colorado State University. Libraries"],"dc:relation.ispartof":["2000-2019"],"dc:rights":["Copyright and other restrictions may apply. User is responsible for compliance with all applicable laws. For information about copyright law, please see https://libguides.colostate.edu/copyright.","This Item is protected by copyright and/or related rights (https://rightsstatements.org/vocab/InC/1.0/). You are free to use this Item in any way that is permitted by the copyright and related rights legislation that applies to your use. For other uses you need to obtain permission from the rights-holder(s)."],"dc:rights.license":["Per the terms of a contractual agreement, all use of this item is limited to the non-commercial use of Colorado State University and its authorized users."],"dc:subject":["radiation","nuclear physics"],"dc:title":["The response of a spherical tissue-equivalent proportional counter to iron particles from 200-1000 MeV/nucleon"],"dc:type":["Text"],"others:access_status":["open.access"],"thesis:degree_discipline":["Environmental and Radiological Health Sciences"],"thesis:degree_level":["Doctoral"],"thesis:degree_name":["Doctor of Philosophy (Ph.D.)"],"thesis:institution_name":["Colorado State University"]},"updated_at":"2026-11-19T07:13:00Z"}