{"id":{"repo_id":"colostate","oai_identifier":"oai:mountainscholar.org:10217/72373"},"canonical_url":"https://search.ndltd.org/etd/colostate/oai:mountainscholar.org:10217/72373","repository":{"repo_id":"colostate","name":"Colorado State University","base_url":"https://api.mountainscholar.org/server/oai/request"},"display":{"title":"Comparison of MCNP modeling against empirical data for the measurement of gamma fields due to actinide oxides in a glovebox","abstract":"Los Alamos National Laboratory (LANL) is a facility that conducts research in the fields of global security, astrophysics, nuclear energy, and materials science. At Technical Area 55 (TA-55) actinide oxides used for experimental nuclear fuel research are placed in gloveboxes to be manipulated by glovebox operators. The actinide oxides are radioactive and emit gamma rays which impact the glovebox operator. Although proper precautions protect workers from unnecessary dose, the measurement and characterization of the gamma fields are useful in deciding if multiple dosimetry may be necessary as per standards at the lab and national standards. Experimental measurements were made by radiation protection personnel of TA-55 at the glovebox containing different actinide oxides. Thermoluminescent dosimeters (TLDs) were utilized to determine the dose to workers at the glovebox. A lead apron covered some of the TLDs while others were left unshielded to simulate shielded and unshielded portions of the body. Monte Carlo N-Particle Code Version 5 (MCNP5) was used to model and simulate the experimental setup at TA-55 to determine the efficacy of the lead apron and to determine the spatiality of the dose distribution as required to determine whether multiple dosimetry is necessary or not. Multiple dosimetry was found to not be required given that the TLD's are worn on the chest, at the location of highest dose.","abstract_html":"Los Alamos National Laboratory (LANL) is a facility that conducts research in the fields of global security, astrophysics, nuclear energy, and materials science. At Technical Area 55 (TA-55) actinide oxides used for experimental nuclear fuel research are placed in gloveboxes to be manipulated by glovebox operators. The actinide oxides are radioactive and emit gamma rays which impact the glovebox operator. Although proper precautions protect workers from unnecessary dose, the measurement and characterization of the gamma fields are useful in deciding if multiple dosimetry may be necessary as per standards at the lab and national standards. Experimental measurements were made by radiation protection personnel of TA-55 at the glovebox containing different actinide oxides. Thermoluminescent dosimeters (TLDs) were utilized to determine the dose to workers at the glovebox. A lead apron covered some of the TLDs while others were left unshielded to simulate shielded and unshielded portions of the body. Monte Carlo N-Particle Code Version 5 (MCNP5) was used to model and simulate the experimental setup at TA-55 to determine the efficacy of the lead apron and to determine the spatiality of the dose distribution as required to determine whether multiple dosimetry is necessary or not. Multiple dosimetry was found to not be required given that the TLD&#x27;s are worn on the chest, at the location of highest dose.","abstract_has_math":false,"creators":["Adams, David Wright, author","Brandl, Alexander, advisor","Johnson, Thomas E., committee member","Lindsay, James E., committee member"],"institution":"Colorado State University. Libraries","degree_name":"Master of Science (M.S.)","degree_level":"Masters","degree_discipline":"Environmental and Radiological Health Sciences","degree_department":null,"school":null,"contributors":[],"advisors":[],"committee_chairs":[],"committee_members":[],"year":2012,"date_issued":"2012","date_published":"2012","updated_at":"2026-11-19T07:17:18Z","subjects":["actinide oxide","Monte Carlo","MCNP","glovebox","dosimetry"],"languages":["eng","English"],"rights":["Copyright and other restrictions may apply. User is responsible for compliance with all applicable laws. For information about copyright law, please see https://libguides.colostate.edu/copyright.","This Item is protected by copyright and/or related rights (https://rightsstatements.org/vocab/InC/1.0/). You are free to use this Item in any way that is permitted by the copyright and related rights legislation that applies to your use. For other uses you need to obtain permission from the rights-holder(s)."],"rights_urls":[],"identifier_entries":[{"key":"dc:identifier.uri","label":"Identifier URI","values":["http://hdl.handle.net/10217/72373"],"render_values":[{"text":"http://hdl.handle.net/10217/72373","href":"https://hdl.handle.net/10217/72373","code":true}]},{"key":"dc:identifier","label":"Identifier","values":["Adams_colostate_0053N_11495.pdf","ETDF2012400410ERHS"],"render_values":[{"text":"Adams_colostate_0053N_11495.pdf","href":null,"code":true},{"text":"ETDF2012400410ERHS","href":null,"code":true}]}],"person_identifier_entries":[]},"links":{"outbound_url":"https://doi.org/10.25675/3.023405","outbound_label":"DOI","outbound_source":"dc:identifier.uri","record_url":"https://doi.org/10.25675/3.023405","record_label":"Repository record","record_kind":"doi","record_source":"dc:identifier.uri","access_status":null,"embargo_until":null,"access_note":null},"oai_pmh_record":{"url":"https://union.ndltd.org/oai-pmh/?verb=GetRecord&metadataPrefix=oai_dc&identifier=oai%3Aunion.ndltd.org%3Arepo%3Acolostate%3Aoai%3Amountainscholar.org%3A10217%2F72373","prefix":"oai_dc"},"source_record":{"url":"https://api.mountainscholar.org/server/oai/request?verb=GetRecord&metadataPrefix=dim&identifier=oai%3Amountainscholar.org%3A10217%2F72373","prefix":"dim"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:creator","label":"Author","values":["Adams, David Wright, author","Brandl, Alexander, advisor","Johnson, Thomas E., committee member","Lindsay, James E., committee member"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2007-01-03T08:30:13Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2007-01-03T08:30:13Z"]},{"key":"dc:date.issued","label":"Date","values":["2012"]},{"key":"dc:publisher","label":"Institution","values":["Colorado State University. Libraries"]},{"key":"dc:relation.ispartof","label":"Dc Relation Ispartof","values":["2000-2019"]},{"key":"dc:type","label":"Dc Type","values":["Text"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Environmental and Radiological Health Sciences"]},{"key":"thesis:degree_level","label":"Degree Level","values":["Masters"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Master of Science (M.S.)"]},{"key":"thesis:institution_name","label":"Thesis Institution Name","values":["Colorado State University"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["actinide oxide","Monte Carlo","MCNP","glovebox","dosimetry"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language","label":"Dc Language","values":["English"]},{"key":"dc:language.iso","label":"Language (ISO)","values":["eng"]},{"key":"dc:rights","label":"Dc Rights","values":["Copyright and other restrictions may apply. User is responsible for compliance with all applicable laws. For information about copyright law, please see https://libguides.colostate.edu/copyright.","This Item is protected by copyright and/or related rights (https://rightsstatements.org/vocab/InC/1.0/). You are free to use this Item in any way that is permitted by the copyright and related rights legislation that applies to your use. For other uses you need to obtain permission from the rights-holder(s)."]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier","label":"Identifier","values":["Adams_colostate_0053N_11495.pdf","ETDF2012400410ERHS"]},{"key":"dc:identifier.uri","label":"Identifier URI","values":["http://hdl.handle.net/10217/72373","https://doi.org/10.25675/3.023405"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["Los Alamos National Laboratory (LANL) is a facility that conducts research in the fields of global security, astrophysics, nuclear energy, and materials science. At Technical Area 55 (TA-55) actinide oxides used for experimental nuclear fuel research are placed in gloveboxes to be manipulated by glovebox operators. The actinide oxides are radioactive and emit gamma rays which impact the glovebox operator. Although proper precautions protect workers from unnecessary dose, the measurement and characterization of the gamma fields are useful in deciding if multiple dosimetry may be necessary as per standards at the lab and national standards. Experimental measurements were made by radiation protection personnel of TA-55 at the glovebox containing different actinide oxides. Thermoluminescent dosimeters (TLDs) were utilized to determine the dose to workers at the glovebox. A lead apron covered some of the TLDs while others were left unshielded to simulate shielded and unshielded portions of the body. Monte Carlo N-Particle Code Version 5 (MCNP5) was used to model and simulate the experimental setup at TA-55 to determine the efficacy of the lead apron and to determine the spatiality of the dose distribution as required to determine whether multiple dosimetry is necessary or not. Multiple dosimetry was found to not be required given that the TLD's are worn on the chest, at the location of highest dose."]},{"key":"dc:format.medium","label":"Dc Format Medium","values":["born digital","masters theses"]},{"key":"dc:title","label":"Title","values":["Comparison of MCNP modeling against empirical data for the measurement of gamma fields due to actinide oxides in a glovebox"]},{"key":"others:access_status","label":"Others Access Status","values":["open.access"]}]}],"canonical_facts":{"dc:creator":["Adams, David Wright, author","Brandl, Alexander, advisor","Johnson, Thomas E., committee member","Lindsay, James E., committee member"],"dc:date.accessioned":["2007-01-03T08:30:13Z"],"dc:date.available":["2007-01-03T08:30:13Z"],"dc:date.issued":["2012"],"dc:description.abstract":["Los Alamos National Laboratory (LANL) is a facility that conducts research in the fields of global security, astrophysics, nuclear energy, and materials science. At Technical Area 55 (TA-55) actinide oxides used for experimental nuclear fuel research are placed in gloveboxes to be manipulated by glovebox operators. The actinide oxides are radioactive and emit gamma rays which impact the glovebox operator. Although proper precautions protect workers from unnecessary dose, the measurement and characterization of the gamma fields are useful in deciding if multiple dosimetry may be necessary as per standards at the lab and national standards. Experimental measurements were made by radiation protection personnel of TA-55 at the glovebox containing different actinide oxides. Thermoluminescent dosimeters (TLDs) were utilized to determine the dose to workers at the glovebox. A lead apron covered some of the TLDs while others were left unshielded to simulate shielded and unshielded portions of the body. Monte Carlo N-Particle Code Version 5 (MCNP5) was used to model and simulate the experimental setup at TA-55 to determine the efficacy of the lead apron and to determine the spatiality of the dose distribution as required to determine whether multiple dosimetry is necessary or not. Multiple dosimetry was found to not be required given that the TLD's are worn on the chest, at the location of highest dose."],"dc:format.medium":["born digital","masters theses"],"dc:identifier":["Adams_colostate_0053N_11495.pdf","ETDF2012400410ERHS"],"dc:identifier.uri":["http://hdl.handle.net/10217/72373","https://doi.org/10.25675/3.023405"],"dc:language":["English"],"dc:language.iso":["eng"],"dc:publisher":["Colorado State University. Libraries"],"dc:relation.ispartof":["2000-2019"],"dc:rights":["Copyright and other restrictions may apply. User is responsible for compliance with all applicable laws. For information about copyright law, please see https://libguides.colostate.edu/copyright.","This Item is protected by copyright and/or related rights (https://rightsstatements.org/vocab/InC/1.0/). You are free to use this Item in any way that is permitted by the copyright and related rights legislation that applies to your use. For other uses you need to obtain permission from the rights-holder(s)."],"dc:subject":["actinide oxide","Monte Carlo","MCNP","glovebox","dosimetry"],"dc:title":["Comparison of MCNP modeling against empirical data for the measurement of gamma fields due to actinide oxides in a glovebox"],"dc:type":["Text"],"others:access_status":["open.access"],"thesis:degree_discipline":["Environmental and Radiological Health Sciences"],"thesis:degree_level":["Masters"],"thesis:degree_name":["Master of Science (M.S.)"],"thesis:institution_name":["Colorado State University"]},"updated_at":"2026-11-19T07:17:18Z"}