{"id":{"repo_id":"colostate","oai_identifier":"oai:mountainscholar.org:10217/75298"},"canonical_url":"https://search.ndltd.org/etd/colostate/oai:mountainscholar.org:10217/75298","repository":{"repo_id":"colostate","name":"Colorado State University","base_url":"https://api.mountainscholar.org/server/oai/request"},"display":{"title":"Servo blower control for powered air purifying respirators","abstract":"Powered air purifying respirators (PAPRs) are a form of respiratory protection that uses a motor-coupled fan to provide filtered air to a user through a positive pressure mask. Three types of PAPR devices have been developed of which breath-responsive PAPRs are the most recent. The benefits of breath-responsive PAPRs have been identified and regulatory performance requirements have been put in place for these devices, however, no devices have been certified by any regulatory agencies. This study proposes a novel conceptual design for a breath-responsive PAPR and describes a dynamic simulation of the characteristics of this new PAPR compared to a constant flow design as exercised by a simulated breathing cycle. Additionally, this study describes a prototype of the breath-responsive concept with experimental evaluation of the prototype against regulatory requirements and conceptual design targets.","abstract_html":"Powered air purifying respirators (PAPRs) are a form of respiratory protection that uses a motor-coupled fan to provide filtered air to a user through a positive pressure mask. Three types of PAPR devices have been developed of which breath-responsive PAPRs are the most recent. The benefits of breath-responsive PAPRs have been identified and regulatory performance requirements have been put in place for these devices, however, no devices have been certified by any regulatory agencies. This study proposes a novel conceptual design for a breath-responsive PAPR and describes a dynamic simulation of the characteristics of this new PAPR compared to a constant flow design as exercised by a simulated breathing cycle. Additionally, this study describes a prototype of the breath-responsive concept with experimental evaluation of the prototype against regulatory requirements and conceptual design targets.","abstract_has_math":false,"creators":["Wagner, Nicholas Adam, author","Bradley, Thomas H., advisor","Williams, John D., committee member","Young, Peter M., committee member"],"institution":"Colorado State University. Libraries","degree_name":"Master of Science (M.S.)","degree_level":"Masters","degree_discipline":"Mechanical Engineering","degree_department":null,"school":null,"contributors":[],"advisors":[],"committee_chairs":[],"committee_members":[],"year":2012,"date_issued":"2012","date_published":"2012","updated_at":"2026-11-19T07:11:22Z","subjects":["breath responsive","control system","PAPR","PID","powered air purifying respirator","respiratory protection"],"languages":["eng","English"],"rights":["Copyright and other restrictions may apply. User is responsible for compliance with all applicable laws. For information about copyright law, please see https://libguides.colostate.edu/copyright.","This Item is protected by copyright and/or related rights (https://rightsstatements.org/vocab/InC/1.0/). You are free to use this Item in any way that is permitted by the copyright and related rights legislation that applies to your use. For other uses you need to obtain permission from the rights-holder(s)."],"rights_urls":[],"identifier_entries":[{"key":"dc:identifier.uri","label":"Identifier URI","values":["http://hdl.handle.net/10217/75298"],"render_values":[{"text":"http://hdl.handle.net/10217/75298","href":"https://hdl.handle.net/10217/75298","code":true}]},{"key":"dc:identifier","label":"Identifier","values":["Wagner_colostate_0053N_11432.pdf","ETDF2012400460MCEN"],"render_values":[{"text":"Wagner_colostate_0053N_11432.pdf","href":null,"code":true},{"text":"ETDF2012400460MCEN","href":null,"code":true}]}],"person_identifier_entries":[]},"links":{"outbound_url":"https://doi.org/10.25675/3.020791","outbound_label":"DOI","outbound_source":"dc:identifier.uri","record_url":"https://doi.org/10.25675/3.020791","record_label":"Repository record","record_kind":"doi","record_source":"dc:identifier.uri","access_status":null,"embargo_until":null,"access_note":null},"oai_pmh_record":{"url":"https://union.ndltd.org/oai-pmh/?verb=GetRecord&metadataPrefix=oai_dc&identifier=oai%3Aunion.ndltd.org%3Arepo%3Acolostate%3Aoai%3Amountainscholar.org%3A10217%2F75298","prefix":"oai_dc"},"source_record":{"url":"https://api.mountainscholar.org/server/oai/request?verb=GetRecord&metadataPrefix=dim&identifier=oai%3Amountainscholar.org%3A10217%2F75298","prefix":"dim"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:creator","label":"Author","values":["Wagner, Nicholas Adam, author","Bradley, Thomas H., advisor","Williams, John D., committee member","Young, Peter M., committee member"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2007-01-03T08:40:49Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2007-01-03T08:40:49Z"]},{"key":"dc:date.issued","label":"Date","values":["2012"]},{"key":"dc:publisher","label":"Institution","values":["Colorado State University. Libraries"]},{"key":"dc:relation.ispartof","label":"Dc Relation Ispartof","values":["2000-2019"]},{"key":"dc:type","label":"Dc Type","values":["Text"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Mechanical Engineering"]},{"key":"thesis:degree_level","label":"Degree Level","values":["Masters"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Master of Science (M.S.)"]},{"key":"thesis:institution_name","label":"Thesis Institution Name","values":["Colorado State University"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["breath responsive","control system","PAPR","PID","powered air purifying respirator","respiratory protection"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language","label":"Dc Language","values":["English"]},{"key":"dc:language.iso","label":"Language (ISO)","values":["eng"]},{"key":"dc:rights","label":"Dc Rights","values":["Copyright and other restrictions may apply. User is responsible for compliance with all applicable laws. For information about copyright law, please see https://libguides.colostate.edu/copyright.","This Item is protected by copyright and/or related rights (https://rightsstatements.org/vocab/InC/1.0/). You are free to use this Item in any way that is permitted by the copyright and related rights legislation that applies to your use. For other uses you need to obtain permission from the rights-holder(s)."]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier","label":"Identifier","values":["Wagner_colostate_0053N_11432.pdf","ETDF2012400460MCEN"]},{"key":"dc:identifier.uri","label":"Identifier URI","values":["http://hdl.handle.net/10217/75298","https://doi.org/10.25675/3.020791"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["Powered air purifying respirators (PAPRs) are a form of respiratory protection that uses a motor-coupled fan to provide filtered air to a user through a positive pressure mask. Three types of PAPR devices have been developed of which breath-responsive PAPRs are the most recent. The benefits of breath-responsive PAPRs have been identified and regulatory performance requirements have been put in place for these devices, however, no devices have been certified by any regulatory agencies. This study proposes a novel conceptual design for a breath-responsive PAPR and describes a dynamic simulation of the characteristics of this new PAPR compared to a constant flow design as exercised by a simulated breathing cycle. Additionally, this study describes a prototype of the breath-responsive concept with experimental evaluation of the prototype against regulatory requirements and conceptual design targets."]},{"key":"dc:format.medium","label":"Dc Format Medium","values":["born digital","masters theses"]},{"key":"dc:title","label":"Title","values":["Servo blower control for powered air purifying respirators"]},{"key":"others:access_status","label":"Others Access Status","values":["open.access"]}]}],"canonical_facts":{"dc:creator":["Wagner, Nicholas Adam, author","Bradley, Thomas H., advisor","Williams, John D., committee member","Young, Peter M., committee member"],"dc:date.accessioned":["2007-01-03T08:40:49Z"],"dc:date.available":["2007-01-03T08:40:49Z"],"dc:date.issued":["2012"],"dc:description.abstract":["Powered air purifying respirators (PAPRs) are a form of respiratory protection that uses a motor-coupled fan to provide filtered air to a user through a positive pressure mask. Three types of PAPR devices have been developed of which breath-responsive PAPRs are the most recent. The benefits of breath-responsive PAPRs have been identified and regulatory performance requirements have been put in place for these devices, however, no devices have been certified by any regulatory agencies. This study proposes a novel conceptual design for a breath-responsive PAPR and describes a dynamic simulation of the characteristics of this new PAPR compared to a constant flow design as exercised by a simulated breathing cycle. Additionally, this study describes a prototype of the breath-responsive concept with experimental evaluation of the prototype against regulatory requirements and conceptual design targets."],"dc:format.medium":["born digital","masters theses"],"dc:identifier":["Wagner_colostate_0053N_11432.pdf","ETDF2012400460MCEN"],"dc:identifier.uri":["http://hdl.handle.net/10217/75298","https://doi.org/10.25675/3.020791"],"dc:language":["English"],"dc:language.iso":["eng"],"dc:publisher":["Colorado State University. Libraries"],"dc:relation.ispartof":["2000-2019"],"dc:rights":["Copyright and other restrictions may apply. User is responsible for compliance with all applicable laws. For information about copyright law, please see https://libguides.colostate.edu/copyright.","This Item is protected by copyright and/or related rights (https://rightsstatements.org/vocab/InC/1.0/). You are free to use this Item in any way that is permitted by the copyright and related rights legislation that applies to your use. For other uses you need to obtain permission from the rights-holder(s)."],"dc:subject":["breath responsive","control system","PAPR","PID","powered air purifying respirator","respiratory protection"],"dc:title":["Servo blower control for powered air purifying respirators"],"dc:type":["Text"],"others:access_status":["open.access"],"thesis:degree_discipline":["Mechanical Engineering"],"thesis:degree_level":["Masters"],"thesis:degree_name":["Master of Science (M.S.)"],"thesis:institution_name":["Colorado State University"]},"updated_at":"2026-11-19T07:11:22Z"}