{"id":{"repo_id":"colostate","oai_identifier":"oai:mountainscholar.org:10217/80231"},"canonical_url":"https://search.ndltd.org/etd/colostate/oai:mountainscholar.org:10217/80231","repository":{"repo_id":"colostate","name":"Colorado State University","base_url":"https://api.mountainscholar.org/server/oai/request"},"display":{"title":"Comparison of hexavalent chromium and welding fumes inside and outside of the welding helmet","abstract":"The primary objective of this study was to determine if welding fumes and specific metal concentrations were significantly different between samples taken inside and outside of the welding helmet to determine the most appropriate location of the personal sampling device and best estimate exposure. Personal air samples were collected simultaneously inside and outside of the welding helmet for concentration comparison of welding fumes (n = 12) and hexavalent chromium (n = 15) during stainless steel tungsten inert gas welding tasks. A total of fifteen welders were sampled in a manufacturing setting and a brewery for a total of 27 inside and outside paired samples. A statistically significance difference (p = 0.05) between inside and outside welding helmet concentrations was found for total welding fumes, iron, total chromium, and nickel using a Wilcoxon paired test, where most of the inside-helmet concentrations were lower. Hexavalent chromium and manganese concentrations were not significantly different when comparing inside and outside welding helmet concentrations. A correlation among welding fumes, iron, nickel, and total chromium concentrations was observed utilizing Spearman's rank-order correlation. The mean for hexavalent chromium concentrations difference was 11 μg/m3, when the outlier was included in the analysis and 0.07 μg/m3 without the outlier. The median concentrations difference was 0.06 μg/m3 with or without the outlier in the analysis. The 95% confidence interval for hexavalent chromium inside concentration was 0.1 μg/m3 to 0.34 μg/m3 and 0.13 μg/m3 to 0.4 μg/m3 for outside of the welding helmet concentration. One sample set for hexavalent chromium exceeded the permissible exposure limit (PEL), recommended exposure limit (REL), and threshold limit value (TLV). Based on the results, a high variation of concentrations was found between the inside and outside of the welding helmet concentrations depending on the metal fume analyzed. Manganese had the lowest metal content in the stainless steel welding rods as well as the sampled welding fumes. The greatest variation in concentration ratios was observed for manganese and hexavalent chromium when comparing inside and outside concentrations. These two factors, lower metal contribution in welding rods and variation in concentrations can be speculated to affect the statistical non significant difference found for manganese and hexavalent chromium inside and outside of the welding helmet concentrations. The welding helmet seemed to be protective for some metals, but it should not be assumed that protection will be provided by the use of it. As for sampling location for best welding fumes assessment monitoring, it is recommended that sampling is done outside. Welders often remove their welding helmets to verify the weld, and inside of the welding helmet sampling location may be compromised as it may change when the welding helmet is in the upward position.","abstract_html":"The primary objective of this study was to determine if welding fumes and specific metal concentrations were significantly different between samples taken inside and outside of the welding helmet to determine the most appropriate location of the personal sampling device and best estimate exposure. Personal air samples were collected simultaneously inside and outside of the welding helmet for concentration comparison of welding fumes (n = 12) and hexavalent chromium (n = 15) during stainless steel tungsten inert gas welding tasks. A total of fifteen welders were sampled in a manufacturing setting and a brewery for a total of 27 inside and outside paired samples. A statistically significance difference (p = 0.05) between inside and outside welding helmet concentrations was found for total welding fumes, iron, total chromium, and nickel using a Wilcoxon paired test, where most of the inside-helmet concentrations were lower. Hexavalent chromium and manganese concentrations were not significantly different when comparing inside and outside welding helmet concentrations. A correlation among welding fumes, iron, nickel, and total chromium concentrations was observed utilizing Spearman&#x27;s rank-order correlation. The mean for hexavalent chromium concentrations difference was 11 μg/m3, when the outlier was included in the analysis and 0.07 μg/m3 without the outlier. The median concentrations difference was 0.06 μg/m3 with or without the outlier in the analysis. The 95% confidence interval for hexavalent chromium inside concentration was 0.1 μg/m3 to 0.34 μg/m3 and 0.13 μg/m3 to 0.4 μg/m3 for outside of the welding helmet concentration. One sample set for hexavalent chromium exceeded the permissible exposure limit (PEL), recommended exposure limit (REL), and threshold limit value (TLV). Based on the results, a high variation of concentrations was found between the inside and outside of the welding helmet concentrations depending on the metal fume analyzed. Manganese had the lowest metal content in the stainless steel welding rods as well as the sampled welding fumes. The greatest variation in concentration ratios was observed for manganese and hexavalent chromium when comparing inside and outside concentrations. These two factors, lower metal contribution in welding rods and variation in concentrations can be speculated to affect the statistical non significant difference found for manganese and hexavalent chromium inside and outside of the welding helmet concentrations. The welding helmet seemed to be protective for some metals, but it should not be assumed that protection will be provided by the use of it. As for sampling location for best welding fumes assessment monitoring, it is recommended that sampling is done outside. Welders often remove their welding helmets to verify the weld, and inside of the welding helmet sampling location may be compromised as it may change when the welding helmet is in the upward position.","abstract_has_math":false,"creators":["Diaz-Rivera, Karen, author","Brazile, William, advisor","Reynolds, Stephen, committee member","Collett, Jeffrey L., committee member"],"institution":"Colorado State University. Libraries","degree_name":"Master of Science (M.S.)","degree_level":"Masters","degree_discipline":"Environmental and Radiological Health Sciences","degree_department":null,"school":null,"contributors":[],"advisors":[],"committee_chairs":[],"committee_members":[],"year":2013,"date_issued":"2013","date_published":"2013","updated_at":"2026-11-19T07:17:30Z","subjects":["welding fumes","hexavalent chromium","welding helmet"],"languages":["eng","English"],"rights":["Copyright and other restrictions may apply. User is responsible for compliance with all applicable laws. For information about copyright law, please see https://libguides.colostate.edu/copyright.","This Item is protected by copyright and/or related rights (https://rightsstatements.org/vocab/InC/1.0/). You are free to use this Item in any way that is permitted by the copyright and related rights legislation that applies to your use. For other uses you need to obtain permission from the rights-holder(s)."],"rights_urls":[],"identifier_entries":[{"key":"dc:identifier.uri","label":"Identifier URI","values":["http://hdl.handle.net/10217/80231"],"render_values":[{"text":"http://hdl.handle.net/10217/80231","href":"https://hdl.handle.net/10217/80231","code":true}]},{"key":"dc:identifier","label":"Identifier","values":["DiazRivera_colostate_0053N_11958.pdf"],"render_values":[{"text":"DiazRivera_colostate_0053N_11958.pdf","href":null,"code":true}]}],"person_identifier_entries":[]},"links":{"outbound_url":"https://doi.org/10.25675/3.023604","outbound_label":"DOI","outbound_source":"dc:identifier.uri","record_url":"https://doi.org/10.25675/3.023604","record_label":"Repository record","record_kind":"doi","record_source":"dc:identifier.uri","access_status":null,"embargo_until":null,"access_note":null},"oai_pmh_record":{"url":"https://union.ndltd.org/oai-pmh/?verb=GetRecord&metadataPrefix=oai_dc&identifier=oai%3Aunion.ndltd.org%3Arepo%3Acolostate%3Aoai%3Amountainscholar.org%3A10217%2F80231","prefix":"oai_dc"},"source_record":{"url":"https://api.mountainscholar.org/server/oai/request?verb=GetRecord&metadataPrefix=dim&identifier=oai%3Amountainscholar.org%3A10217%2F80231","prefix":"dim"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:creator","label":"Author","values":["Diaz-Rivera, Karen, author","Brazile, William, advisor","Reynolds, Stephen, committee member","Collett, Jeffrey L., committee member"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2007-01-03T05:55:14Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2007-01-03T05:55:14Z"]},{"key":"dc:date.issued","label":"Date","values":["2013"]},{"key":"dc:publisher","label":"Institution","values":["Colorado State University. Libraries"]},{"key":"dc:relation.ispartof","label":"Dc Relation Ispartof","values":["2000-2019"]},{"key":"dc:type","label":"Dc Type","values":["Text"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Environmental and Radiological Health Sciences"]},{"key":"thesis:degree_level","label":"Degree Level","values":["Masters"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Master of Science (M.S.)"]},{"key":"thesis:institution_name","label":"Thesis Institution Name","values":["Colorado State University"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["welding fumes","hexavalent chromium","welding helmet"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language","label":"Dc Language","values":["English"]},{"key":"dc:language.iso","label":"Language (ISO)","values":["eng"]},{"key":"dc:rights","label":"Dc Rights","values":["Copyright and other restrictions may apply. User is responsible for compliance with all applicable laws. For information about copyright law, please see https://libguides.colostate.edu/copyright.","This Item is protected by copyright and/or related rights (https://rightsstatements.org/vocab/InC/1.0/). You are free to use this Item in any way that is permitted by the copyright and related rights legislation that applies to your use. For other uses you need to obtain permission from the rights-holder(s)."]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier","label":"Identifier","values":["DiazRivera_colostate_0053N_11958.pdf"]},{"key":"dc:identifier.uri","label":"Identifier URI","values":["http://hdl.handle.net/10217/80231","https://doi.org/10.25675/3.023604"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["The primary objective of this study was to determine if welding fumes and specific metal concentrations were significantly different between samples taken inside and outside of the welding helmet to determine the most appropriate location of the personal sampling device and best estimate exposure. Personal air samples were collected simultaneously inside and outside of the welding helmet for concentration comparison of welding fumes (n = 12) and hexavalent chromium (n = 15) during stainless steel tungsten inert gas welding tasks. A total of fifteen welders were sampled in a manufacturing setting and a brewery for a total of 27 inside and outside paired samples. A statistically significance difference (p = 0.05) between inside and outside welding helmet concentrations was found for total welding fumes, iron, total chromium, and nickel using a Wilcoxon paired test, where most of the inside-helmet concentrations were lower. Hexavalent chromium and manganese concentrations were not significantly different when comparing inside and outside welding helmet concentrations. A correlation among welding fumes, iron, nickel, and total chromium concentrations was observed utilizing Spearman's rank-order correlation. The mean for hexavalent chromium concentrations difference was 11 μg/m3, when the outlier was included in the analysis and 0.07 μg/m3 without the outlier. The median concentrations difference was 0.06 μg/m3 with or without the outlier in the analysis. The 95% confidence interval for hexavalent chromium inside concentration was 0.1 μg/m3 to 0.34 μg/m3 and 0.13 μg/m3 to 0.4 μg/m3 for outside of the welding helmet concentration. One sample set for hexavalent chromium exceeded the permissible exposure limit (PEL), recommended exposure limit (REL), and threshold limit value (TLV). Based on the results, a high variation of concentrations was found between the inside and outside of the welding helmet concentrations depending on the metal fume analyzed. Manganese had the lowest metal content in the stainless steel welding rods as well as the sampled welding fumes. The greatest variation in concentration ratios was observed for manganese and hexavalent chromium when comparing inside and outside concentrations. These two factors, lower metal contribution in welding rods and variation in concentrations can be speculated to affect the statistical non significant difference found for manganese and hexavalent chromium inside and outside of the welding helmet concentrations. The welding helmet seemed to be protective for some metals, but it should not be assumed that protection will be provided by the use of it. As for sampling location for best welding fumes assessment monitoring, it is recommended that sampling is done outside. Welders often remove their welding helmets to verify the weld, and inside of the welding helmet sampling location may be compromised as it may change when the welding helmet is in the upward position."]},{"key":"dc:format.medium","label":"Dc Format Medium","values":["born digital","masters theses"]},{"key":"dc:title","label":"Title","values":["Comparison of hexavalent chromium and welding fumes inside and outside of the welding helmet"]},{"key":"others:access_status","label":"Others Access Status","values":["open.access"]}]}],"canonical_facts":{"dc:creator":["Diaz-Rivera, Karen, author","Brazile, William, advisor","Reynolds, Stephen, committee member","Collett, Jeffrey L., committee member"],"dc:date.accessioned":["2007-01-03T05:55:14Z"],"dc:date.available":["2007-01-03T05:55:14Z"],"dc:date.issued":["2013"],"dc:description.abstract":["The primary objective of this study was to determine if welding fumes and specific metal concentrations were significantly different between samples taken inside and outside of the welding helmet to determine the most appropriate location of the personal sampling device and best estimate exposure. Personal air samples were collected simultaneously inside and outside of the welding helmet for concentration comparison of welding fumes (n = 12) and hexavalent chromium (n = 15) during stainless steel tungsten inert gas welding tasks. A total of fifteen welders were sampled in a manufacturing setting and a brewery for a total of 27 inside and outside paired samples. A statistically significance difference (p = 0.05) between inside and outside welding helmet concentrations was found for total welding fumes, iron, total chromium, and nickel using a Wilcoxon paired test, where most of the inside-helmet concentrations were lower. Hexavalent chromium and manganese concentrations were not significantly different when comparing inside and outside welding helmet concentrations. A correlation among welding fumes, iron, nickel, and total chromium concentrations was observed utilizing Spearman's rank-order correlation. The mean for hexavalent chromium concentrations difference was 11 μg/m3, when the outlier was included in the analysis and 0.07 μg/m3 without the outlier. The median concentrations difference was 0.06 μg/m3 with or without the outlier in the analysis. The 95% confidence interval for hexavalent chromium inside concentration was 0.1 μg/m3 to 0.34 μg/m3 and 0.13 μg/m3 to 0.4 μg/m3 for outside of the welding helmet concentration. One sample set for hexavalent chromium exceeded the permissible exposure limit (PEL), recommended exposure limit (REL), and threshold limit value (TLV). Based on the results, a high variation of concentrations was found between the inside and outside of the welding helmet concentrations depending on the metal fume analyzed. Manganese had the lowest metal content in the stainless steel welding rods as well as the sampled welding fumes. The greatest variation in concentration ratios was observed for manganese and hexavalent chromium when comparing inside and outside concentrations. These two factors, lower metal contribution in welding rods and variation in concentrations can be speculated to affect the statistical non significant difference found for manganese and hexavalent chromium inside and outside of the welding helmet concentrations. The welding helmet seemed to be protective for some metals, but it should not be assumed that protection will be provided by the use of it. As for sampling location for best welding fumes assessment monitoring, it is recommended that sampling is done outside. Welders often remove their welding helmets to verify the weld, and inside of the welding helmet sampling location may be compromised as it may change when the welding helmet is in the upward position."],"dc:format.medium":["born digital","masters theses"],"dc:identifier":["DiazRivera_colostate_0053N_11958.pdf"],"dc:identifier.uri":["http://hdl.handle.net/10217/80231","https://doi.org/10.25675/3.023604"],"dc:language":["English"],"dc:language.iso":["eng"],"dc:publisher":["Colorado State University. Libraries"],"dc:relation.ispartof":["2000-2019"],"dc:rights":["Copyright and other restrictions may apply. User is responsible for compliance with all applicable laws. For information about copyright law, please see https://libguides.colostate.edu/copyright.","This Item is protected by copyright and/or related rights (https://rightsstatements.org/vocab/InC/1.0/). You are free to use this Item in any way that is permitted by the copyright and related rights legislation that applies to your use. For other uses you need to obtain permission from the rights-holder(s)."],"dc:subject":["welding fumes","hexavalent chromium","welding helmet"],"dc:title":["Comparison of hexavalent chromium and welding fumes inside and outside of the welding helmet"],"dc:type":["Text"],"others:access_status":["open.access"],"thesis:degree_discipline":["Environmental and Radiological Health Sciences"],"thesis:degree_level":["Masters"],"thesis:degree_name":["Master of Science (M.S.)"],"thesis:institution_name":["Colorado State University"]},"updated_at":"2026-11-19T07:17:30Z"}