{"id":{"repo_id":"colostate","oai_identifier":"oai:mountainscholar.org:10217/80334"},"canonical_url":"https://search.ndltd.org/etd/colostate/oai:mountainscholar.org:10217/80334","repository":{"repo_id":"colostate","name":"Colorado State University","base_url":"https://api.mountainscholar.org/server/oai/request"},"display":{"title":"Nutrient management control regulation and preparedness of a northern Colorado wastewater treatment plant","abstract":"Excessive nutrients in wastewater treatment plant (WWTP) effluents instigate eutrophication of receiving water bodies. Colorado Department of Public Health and Environment (CDPHE) adopted nutrient management control regulation, also known as regulation 85, to moderate the nutrients released by point sources such as the WWTP effluents. City of Loveland WWTP was selected as the study plant to determine a new treatment process configuration to meet the new limits of total phosphorus < 1 mg/L and total inorganic nitrogen < 15 mg/L in the effluent. BioWin, a windows based modeling software, was used to model and simulate the City of Loveland WWTP. Existing activated sludge step feed process configuration was modeled along with proposed anaerobic, anoxic, oxic (A2O) process for design influent flow of 10 MGD and 5-stage Bardenpho process for future flow of 12 MGD along with A2O process. Existing configuration was modeled to establish the accuracy of BioWin. 5 stage Bardenpho process modeling indicates that higher design HRT of 2 days for anaerobic, 4 days for anoxic, 6 days for aerobic, 4 days for secondary anoxic and 1 day for reaeration has better treatment removal efficiency for nutrients with methanol dosage of 250 gal/d and 1Q internal recycle. Model simulations for A2O process reveals that aerobic reactor to anaerobic reactor volume ratios from 3 to 4 and aerobic reactor to anoxic reactor volume ratio of 2.2 along with internal recycle of 1Q has the better nutrient removal efficiency for design flow of 10 MGD. For 12 MGD influent flow, volume of reactors was increased by 20% to compensate for 20% increase in the flow. Previously mentioned reactor volume ratios are feasible for 12 MGD influent flow with volume ratios of 3 and 4 for aerobic to anaerobic reactors and volume ratios of 1.8 and 2 for aerobic to anoxic reactors. Modeling results indicates that increasing the reactor volume ratio for increased flow can result in better treatment for removal of nutrients with a conservative volume, reducing the operational and maintenance cost.","abstract_html":"Excessive nutrients in wastewater treatment plant (WWTP) effluents instigate eutrophication of receiving water bodies. Colorado Department of Public Health and Environment (CDPHE) adopted nutrient management control regulation, also known as regulation 85, to moderate the nutrients released by point sources such as the WWTP effluents. City of Loveland WWTP was selected as the study plant to determine a new treatment process configuration to meet the new limits of total phosphorus &lt; 1 mg/L and total inorganic nitrogen &lt; 15 mg/L in the effluent. BioWin, a windows based modeling software, was used to model and simulate the City of Loveland WWTP. Existing activated sludge step feed process configuration was modeled along with proposed anaerobic, anoxic, oxic (A2O) process for design influent flow of 10 MGD and 5-stage Bardenpho process for future flow of 12 MGD along with A2O process. Existing configuration was modeled to establish the accuracy of BioWin. 5 stage Bardenpho process modeling indicates that higher design HRT of 2 days for anaerobic, 4 days for anoxic, 6 days for aerobic, 4 days for secondary anoxic and 1 day for reaeration has better treatment removal efficiency for nutrients with methanol dosage of 250 gal/d and 1Q internal recycle. Model simulations for A2O process reveals that aerobic reactor to anaerobic reactor volume ratios from 3 to 4 and aerobic reactor to anoxic reactor volume ratio of 2.2 along with internal recycle of 1Q has the better nutrient removal efficiency for design flow of 10 MGD. For 12 MGD influent flow, volume of reactors was increased by 20% to compensate for 20% increase in the flow. Previously mentioned reactor volume ratios are feasible for 12 MGD influent flow with volume ratios of 3 and 4 for aerobic to anaerobic reactors and volume ratios of 1.8 and 2 for aerobic to anoxic reactors. Modeling results indicates that increasing the reactor volume ratio for increased flow can result in better treatment for removal of nutrients with a conservative volume, reducing the operational and maintenance cost.","abstract_has_math":false,"creators":["Venkatapathi, Keerthivasan, author","Omur-Ozbek, Pinar, advisor","Carlson, Kenneth, committee member","Reardon, Kenneth, committee member"],"institution":"Colorado State University. Libraries","degree_name":"Master of Science (M.S.)","degree_level":"Masters","degree_discipline":"Civil and Environmental Engineering","degree_department":null,"school":null,"contributors":[],"advisors":[],"committee_chairs":[],"committee_members":[],"year":2013,"date_issued":"2013","date_published":"2013","updated_at":"2026-11-19T07:17:11Z","subjects":["wastewater","BioWin modeling"],"languages":["eng","English"],"rights":["Copyright and other restrictions may apply. User is responsible for compliance with all applicable laws. For information about copyright law, please see https://libguides.colostate.edu/copyright.","This Item is protected by copyright and/or related rights (https://rightsstatements.org/vocab/InC/1.0/). You are free to use this Item in any way that is permitted by the copyright and related rights legislation that applies to your use. For other uses you need to obtain permission from the rights-holder(s)."],"rights_urls":[],"identifier_entries":[{"key":"dc:identifier.uri","label":"Identifier URI","values":["http://hdl.handle.net/10217/80334"],"render_values":[{"text":"http://hdl.handle.net/10217/80334","href":"https://hdl.handle.net/10217/80334","code":true}]},{"key":"dc:identifier","label":"Identifier","values":["Venkatapathi_colostate_0053N_11765.pdf","ETDF2013500273CVEE"],"render_values":[{"text":"Venkatapathi_colostate_0053N_11765.pdf","href":null,"code":true},{"text":"ETDF2013500273CVEE","href":null,"code":true}]}],"person_identifier_entries":[]},"links":{"outbound_url":"https://doi.org/10.25675/3.023317","outbound_label":"DOI","outbound_source":"dc:identifier.uri","record_url":"https://doi.org/10.25675/3.023317","record_label":"Repository record","record_kind":"doi","record_source":"dc:identifier.uri","access_status":"embargoed","embargo_until":"2014-09-30","access_note":null},"oai_pmh_record":{"url":"https://union.ndltd.org/oai-pmh/?verb=GetRecord&metadataPrefix=oai_dc&identifier=oai%3Aunion.ndltd.org%3Arepo%3Acolostate%3Aoai%3Amountainscholar.org%3A10217%2F80334","prefix":"oai_dc"},"source_record":{"url":"https://api.mountainscholar.org/server/oai/request?verb=GetRecord&metadataPrefix=dim&identifier=oai%3Amountainscholar.org%3A10217%2F80334","prefix":"dim"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:creator","label":"Author","values":["Venkatapathi, Keerthivasan, author","Omur-Ozbek, Pinar, advisor","Carlson, Kenneth, committee member","Reardon, Kenneth, committee member"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2007-01-03T05:57:03Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2014-09-30T05:57:00Z"]},{"key":"dc:date.embargo","label":"Dc Date Embargo","values":["2014-09-30"]},{"key":"dc:date.issued","label":"Date","values":["2013"]},{"key":"dc:date.liftdate","label":"Dc Date Liftdate","values":["2014-09-30"]},{"key":"dc:publisher","label":"Institution","values":["Colorado State University. Libraries"]},{"key":"dc:relation","label":"Dc Relation","values":["wwdl"]},{"key":"dc:relation.ispartof","label":"Dc Relation Ispartof","values":["2000-2019"]},{"key":"dc:type","label":"Dc Type","values":["Text"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Civil and Environmental Engineering"]},{"key":"thesis:degree_level","label":"Degree Level","values":["Masters"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Master of Science (M.S.)"]},{"key":"thesis:institution_name","label":"Thesis Institution Name","values":["Colorado State University"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["wastewater","BioWin modeling"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language","label":"Dc Language","values":["English"]},{"key":"dc:language.iso","label":"Language (ISO)","values":["eng"]},{"key":"dc:rights","label":"Dc Rights","values":["Copyright and other restrictions may apply. User is responsible for compliance with all applicable laws. For information about copyright law, please see https://libguides.colostate.edu/copyright.","This Item is protected by copyright and/or related rights (https://rightsstatements.org/vocab/InC/1.0/). You are free to use this Item in any way that is permitted by the copyright and related rights legislation that applies to your use. For other uses you need to obtain permission from the rights-holder(s)."]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier","label":"Identifier","values":["Venkatapathi_colostate_0053N_11765.pdf","ETDF2013500273CVEE"]},{"key":"dc:identifier.uri","label":"Identifier URI","values":["http://hdl.handle.net/10217/80334","https://doi.org/10.25675/3.023317"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["Excessive nutrients in wastewater treatment plant (WWTP) effluents instigate eutrophication of receiving water bodies. Colorado Department of Public Health and Environment (CDPHE) adopted nutrient management control regulation, also known as regulation 85, to moderate the nutrients released by point sources such as the WWTP effluents. City of Loveland WWTP was selected as the study plant to determine a new treatment process configuration to meet the new limits of total phosphorus < 1 mg/L and total inorganic nitrogen < 15 mg/L in the effluent. BioWin, a windows based modeling software, was used to model and simulate the City of Loveland WWTP. Existing activated sludge step feed process configuration was modeled along with proposed anaerobic, anoxic, oxic (A2O) process for design influent flow of 10 MGD and 5-stage Bardenpho process for future flow of 12 MGD along with A2O process. Existing configuration was modeled to establish the accuracy of BioWin. 5 stage Bardenpho process modeling indicates that higher design HRT of 2 days for anaerobic, 4 days for anoxic, 6 days for aerobic, 4 days for secondary anoxic and 1 day for reaeration has better treatment removal efficiency for nutrients with methanol dosage of 250 gal/d and 1Q internal recycle. Model simulations for A2O process reveals that aerobic reactor to anaerobic reactor volume ratios from 3 to 4 and aerobic reactor to anoxic reactor volume ratio of 2.2 along with internal recycle of 1Q has the better nutrient removal efficiency for design flow of 10 MGD. For 12 MGD influent flow, volume of reactors was increased by 20% to compensate for 20% increase in the flow. Previously mentioned reactor volume ratios are feasible for 12 MGD influent flow with volume ratios of 3 and 4 for aerobic to anaerobic reactors and volume ratios of 1.8 and 2 for aerobic to anoxic reactors. Modeling results indicates that increasing the reactor volume ratio for increased flow can result in better treatment for removal of nutrients with a conservative volume, reducing the operational and maintenance cost."]},{"key":"dc:format.medium","label":"Dc Format Medium","values":["born digital","masters theses"]},{"key":"dc:title","label":"Title","values":["Nutrient management control regulation and preparedness of a northern Colorado wastewater treatment plant"]},{"key":"others:access_status","label":"Others Access Status","values":["open.access"]}]}],"canonical_facts":{"dc:creator":["Venkatapathi, Keerthivasan, author","Omur-Ozbek, Pinar, advisor","Carlson, Kenneth, committee member","Reardon, Kenneth, committee member"],"dc:date.accessioned":["2007-01-03T05:57:03Z"],"dc:date.available":["2014-09-30T05:57:00Z"],"dc:date.embargo":["2014-09-30"],"dc:date.issued":["2013"],"dc:date.liftdate":["2014-09-30"],"dc:description.abstract":["Excessive nutrients in wastewater treatment plant (WWTP) effluents instigate eutrophication of receiving water bodies. Colorado Department of Public Health and Environment (CDPHE) adopted nutrient management control regulation, also known as regulation 85, to moderate the nutrients released by point sources such as the WWTP effluents. City of Loveland WWTP was selected as the study plant to determine a new treatment process configuration to meet the new limits of total phosphorus < 1 mg/L and total inorganic nitrogen < 15 mg/L in the effluent. BioWin, a windows based modeling software, was used to model and simulate the City of Loveland WWTP. Existing activated sludge step feed process configuration was modeled along with proposed anaerobic, anoxic, oxic (A2O) process for design influent flow of 10 MGD and 5-stage Bardenpho process for future flow of 12 MGD along with A2O process. Existing configuration was modeled to establish the accuracy of BioWin. 5 stage Bardenpho process modeling indicates that higher design HRT of 2 days for anaerobic, 4 days for anoxic, 6 days for aerobic, 4 days for secondary anoxic and 1 day for reaeration has better treatment removal efficiency for nutrients with methanol dosage of 250 gal/d and 1Q internal recycle. Model simulations for A2O process reveals that aerobic reactor to anaerobic reactor volume ratios from 3 to 4 and aerobic reactor to anoxic reactor volume ratio of 2.2 along with internal recycle of 1Q has the better nutrient removal efficiency for design flow of 10 MGD. For 12 MGD influent flow, volume of reactors was increased by 20% to compensate for 20% increase in the flow. Previously mentioned reactor volume ratios are feasible for 12 MGD influent flow with volume ratios of 3 and 4 for aerobic to anaerobic reactors and volume ratios of 1.8 and 2 for aerobic to anoxic reactors. Modeling results indicates that increasing the reactor volume ratio for increased flow can result in better treatment for removal of nutrients with a conservative volume, reducing the operational and maintenance cost."],"dc:format.medium":["born digital","masters theses"],"dc:identifier":["Venkatapathi_colostate_0053N_11765.pdf","ETDF2013500273CVEE"],"dc:identifier.uri":["http://hdl.handle.net/10217/80334","https://doi.org/10.25675/3.023317"],"dc:language":["English"],"dc:language.iso":["eng"],"dc:publisher":["Colorado State University. Libraries"],"dc:relation":["wwdl"],"dc:relation.ispartof":["2000-2019"],"dc:rights":["Copyright and other restrictions may apply. User is responsible for compliance with all applicable laws. For information about copyright law, please see https://libguides.colostate.edu/copyright.","This Item is protected by copyright and/or related rights (https://rightsstatements.org/vocab/InC/1.0/). You are free to use this Item in any way that is permitted by the copyright and related rights legislation that applies to your use. For other uses you need to obtain permission from the rights-holder(s)."],"dc:subject":["wastewater","BioWin modeling"],"dc:title":["Nutrient management control regulation and preparedness of a northern Colorado wastewater treatment plant"],"dc:type":["Text"],"others:access_status":["open.access"],"thesis:degree_discipline":["Civil and Environmental Engineering"],"thesis:degree_level":["Masters"],"thesis:degree_name":["Master of Science (M.S.)"],"thesis:institution_name":["Colorado State University"]},"updated_at":"2026-11-19T07:17:11Z"}