{"id":{"repo_id":"colostate","oai_identifier":"oai:mountainscholar.org:10217/81030"},"canonical_url":"https://search.ndltd.org/etd/colostate/oai:mountainscholar.org:10217/81030","repository":{"repo_id":"colostate","name":"Colorado State University","base_url":"https://api.mountainscholar.org/server/oai/request"},"display":{"title":"Flowback quality characterization for horizontal wells in Wattenberg field","abstract":"The development of hydraulic fracturing has driven both the need for more fresh water, and also has increased the amount of flowback being produced. Faced with a shortage of usable water, transportation issues, strict environmental regulation and environmental concerns, flowback management is an important topic for oil and gas companies. Recycle and reuse flowback waste is a promising method, since it can simultaneously reduce the need of more fresh water for fracking and decrease the potential environmental issues. Understanding the quality characteristics of flowback is significant for implementing the required treatment of flowback water. Flowback flows back to the surface during and after hydraulic fracturing and often flows for over a period of 3-4 weeks, though most wells finish in seven to 10 days. The fluid contains high total dissolved solids (TDS) and high salinity, and also contains some of the same chemicals that are pumped into wells. The volume of flowback can range from 10%-50% of initial injected fracturing fluid. In our study, sampling time was from March to April 2013 and all the samples were taken separately from Wells Ranch State PC USX #AA16-69-1HNL and Wells Ranch State USX #AA16-68-1HNL. The results in this report used well #68 and well #69. Well #68 was injected with PermStim fracture fluid (injected pH 5.0) and well #69 was injected with SliverStim fracture fluid (injected pH 10.2). Wellhead pressure, temperature, pH, dissolved carbon dioxide (CO2), bicarbonate (HCO3) and dissolved hydrogen sulfide (H2S) were tested in the field once samples were collected. TDS, chloride, sulfate, bicarbonate, aluminum, barium, boron, calcium, iron, magnesium, potassium, silicon, strontium and zirconium were tested by E-Analytics Laboratory. The objective of this paper is to analyze flowback water quality from two horizontal wells, located in the same place, which were injected with two different fracturing fluids. Based on the results of the temporal quality trend, this paper also intends to analyze the impact of different pH on water quality and the possible chemical reactions that occur during drilling and fracturing phases.","abstract_html":"The development of hydraulic fracturing has driven both the need for more fresh water, and also has increased the amount of flowback being produced. Faced with a shortage of usable water, transportation issues, strict environmental regulation and environmental concerns, flowback management is an important topic for oil and gas companies. Recycle and reuse flowback waste is a promising method, since it can simultaneously reduce the need of more fresh water for fracking and decrease the potential environmental issues. Understanding the quality characteristics of flowback is significant for implementing the required treatment of flowback water. Flowback flows back to the surface during and after hydraulic fracturing and often flows for over a period of 3-4 weeks, though most wells finish in seven to 10 days. The fluid contains high total dissolved solids (TDS) and high salinity, and also contains some of the same chemicals that are pumped into wells. The volume of flowback can range from 10%-50% of initial injected fracturing fluid. In our study, sampling time was from March to April 2013 and all the samples were taken separately from Wells Ranch State PC USX #AA16-69-1HNL and Wells Ranch State USX #AA16-68-1HNL. The results in this report used well #68 and well #69. Well #68 was injected with PermStim fracture fluid (injected pH 5.0) and well #69 was injected with SliverStim fracture fluid (injected pH 10.2). Wellhead pressure, temperature, pH, dissolved carbon dioxide (CO2), bicarbonate (HCO3) and dissolved hydrogen sulfide (H2S) were tested in the field once samples were collected. TDS, chloride, sulfate, bicarbonate, aluminum, barium, boron, calcium, iron, magnesium, potassium, silicon, strontium and zirconium were tested by E-Analytics Laboratory. The objective of this paper is to analyze flowback water quality from two horizontal wells, located in the same place, which were injected with two different fracturing fluids. Based on the results of the temporal quality trend, this paper also intends to analyze the impact of different pH on water quality and the possible chemical reactions that occur during drilling and fracturing phases.","abstract_has_math":false,"creators":["Jiang, Xi, author","Carlson, Kenneth H., advisor","Omur-Ozbek, Pinar, committee member","Bradley, Thomas H., committee member"],"institution":"Colorado State University. Libraries","degree_name":"Master of Science (M.S.)","degree_level":"Masters","degree_discipline":"Civil and Environmental Engineering","degree_department":null,"school":null,"contributors":[],"advisors":[],"committee_chairs":[],"committee_members":[],"year":2013,"date_issued":"2013","date_published":"2013","updated_at":"2026-11-19T07:10:57Z","subjects":["Wattenberg field","flowback water","water quality","fracturing fluid"],"languages":["eng","English"],"rights":["Copyright and other restrictions may apply. User is responsible for compliance with all applicable laws. For information about copyright law, please see https://libguides.colostate.edu/copyright.","This Item is protected by copyright and/or related rights (https://rightsstatements.org/vocab/InC/1.0/). You are free to use this Item in any way that is permitted by the copyright and related rights legislation that applies to your use. For other uses you need to obtain permission from the rights-holder(s)."],"rights_urls":[],"identifier_entries":[{"key":"dc:identifier.uri","label":"Identifier URI","values":["http://hdl.handle.net/10217/81030"],"render_values":[{"text":"http://hdl.handle.net/10217/81030","href":"https://hdl.handle.net/10217/81030","code":true}]},{"key":"dc:identifier","label":"Identifier","values":["Jiang_X_colostate_0053N_12009.pdf","ETDF2013500386CVEE"],"render_values":[{"text":"Jiang_X_colostate_0053N_12009.pdf","href":null,"code":true},{"text":"ETDF2013500386CVEE","href":null,"code":true}]}],"person_identifier_entries":[]},"links":{"outbound_url":"https://doi.org/10.25675/3.020361","outbound_label":"DOI","outbound_source":"dc:identifier.uri","record_url":"https://doi.org/10.25675/3.020361","record_label":"Repository record","record_kind":"doi","record_source":"dc:identifier.uri","access_status":null,"embargo_until":null,"access_note":null},"oai_pmh_record":{"url":"https://union.ndltd.org/oai-pmh/?verb=GetRecord&metadataPrefix=oai_dc&identifier=oai%3Aunion.ndltd.org%3Arepo%3Acolostate%3Aoai%3Amountainscholar.org%3A10217%2F81030","prefix":"oai_dc"},"source_record":{"url":"https://api.mountainscholar.org/server/oai/request?verb=GetRecord&metadataPrefix=dim&identifier=oai%3Amountainscholar.org%3A10217%2F81030","prefix":"dim"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:creator","label":"Author","values":["Jiang, Xi, author","Carlson, Kenneth H., advisor","Omur-Ozbek, Pinar, committee member","Bradley, Thomas H., committee member"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2007-01-03T06:11:27Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2007-01-03T06:11:27Z"]},{"key":"dc:date.issued","label":"Date","values":["2013"]},{"key":"dc:publisher","label":"Institution","values":["Colorado State University. Libraries"]},{"key":"dc:relation","label":"Dc Relation","values":["wwdl"]},{"key":"dc:relation.ispartof","label":"Dc Relation Ispartof","values":["2000-2019"]},{"key":"dc:type","label":"Dc Type","values":["Text"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Civil and Environmental Engineering"]},{"key":"thesis:degree_level","label":"Degree Level","values":["Masters"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Master of Science (M.S.)"]},{"key":"thesis:institution_name","label":"Thesis Institution Name","values":["Colorado State University"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Wattenberg field","flowback water","water quality","fracturing fluid"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language","label":"Dc Language","values":["English"]},{"key":"dc:language.iso","label":"Language (ISO)","values":["eng"]},{"key":"dc:rights","label":"Dc Rights","values":["Copyright and other restrictions may apply. User is responsible for compliance with all applicable laws. For information about copyright law, please see https://libguides.colostate.edu/copyright.","This Item is protected by copyright and/or related rights (https://rightsstatements.org/vocab/InC/1.0/). You are free to use this Item in any way that is permitted by the copyright and related rights legislation that applies to your use. For other uses you need to obtain permission from the rights-holder(s)."]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier","label":"Identifier","values":["Jiang_X_colostate_0053N_12009.pdf","ETDF2013500386CVEE"]},{"key":"dc:identifier.uri","label":"Identifier URI","values":["http://hdl.handle.net/10217/81030","https://doi.org/10.25675/3.020361"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["The development of hydraulic fracturing has driven both the need for more fresh water, and also has increased the amount of flowback being produced. Faced with a shortage of usable water, transportation issues, strict environmental regulation and environmental concerns, flowback management is an important topic for oil and gas companies. Recycle and reuse flowback waste is a promising method, since it can simultaneously reduce the need of more fresh water for fracking and decrease the potential environmental issues. Understanding the quality characteristics of flowback is significant for implementing the required treatment of flowback water. Flowback flows back to the surface during and after hydraulic fracturing and often flows for over a period of 3-4 weeks, though most wells finish in seven to 10 days. The fluid contains high total dissolved solids (TDS) and high salinity, and also contains some of the same chemicals that are pumped into wells. The volume of flowback can range from 10%-50% of initial injected fracturing fluid. In our study, sampling time was from March to April 2013 and all the samples were taken separately from Wells Ranch State PC USX #AA16-69-1HNL and Wells Ranch State USX #AA16-68-1HNL. The results in this report used well #68 and well #69. Well #68 was injected with PermStim fracture fluid (injected pH 5.0) and well #69 was injected with SliverStim fracture fluid (injected pH 10.2). Wellhead pressure, temperature, pH, dissolved carbon dioxide (CO2), bicarbonate (HCO3) and dissolved hydrogen sulfide (H2S) were tested in the field once samples were collected. TDS, chloride, sulfate, bicarbonate, aluminum, barium, boron, calcium, iron, magnesium, potassium, silicon, strontium and zirconium were tested by E-Analytics Laboratory. The objective of this paper is to analyze flowback water quality from two horizontal wells, located in the same place, which were injected with two different fracturing fluids. Based on the results of the temporal quality trend, this paper also intends to analyze the impact of different pH on water quality and the possible chemical reactions that occur during drilling and fracturing phases."]},{"key":"dc:format.medium","label":"Dc Format Medium","values":["born digital","masters theses"]},{"key":"dc:title","label":"Title","values":["Flowback quality characterization for horizontal wells in Wattenberg field"]},{"key":"others:access_status","label":"Others Access Status","values":["open.access"]}]}],"canonical_facts":{"dc:creator":["Jiang, Xi, author","Carlson, Kenneth H., advisor","Omur-Ozbek, Pinar, committee member","Bradley, Thomas H., committee member"],"dc:date.accessioned":["2007-01-03T06:11:27Z"],"dc:date.available":["2007-01-03T06:11:27Z"],"dc:date.issued":["2013"],"dc:description.abstract":["The development of hydraulic fracturing has driven both the need for more fresh water, and also has increased the amount of flowback being produced. Faced with a shortage of usable water, transportation issues, strict environmental regulation and environmental concerns, flowback management is an important topic for oil and gas companies. Recycle and reuse flowback waste is a promising method, since it can simultaneously reduce the need of more fresh water for fracking and decrease the potential environmental issues. Understanding the quality characteristics of flowback is significant for implementing the required treatment of flowback water. Flowback flows back to the surface during and after hydraulic fracturing and often flows for over a period of 3-4 weeks, though most wells finish in seven to 10 days. The fluid contains high total dissolved solids (TDS) and high salinity, and also contains some of the same chemicals that are pumped into wells. The volume of flowback can range from 10%-50% of initial injected fracturing fluid. In our study, sampling time was from March to April 2013 and all the samples were taken separately from Wells Ranch State PC USX #AA16-69-1HNL and Wells Ranch State USX #AA16-68-1HNL. The results in this report used well #68 and well #69. Well #68 was injected with PermStim fracture fluid (injected pH 5.0) and well #69 was injected with SliverStim fracture fluid (injected pH 10.2). Wellhead pressure, temperature, pH, dissolved carbon dioxide (CO2), bicarbonate (HCO3) and dissolved hydrogen sulfide (H2S) were tested in the field once samples were collected. TDS, chloride, sulfate, bicarbonate, aluminum, barium, boron, calcium, iron, magnesium, potassium, silicon, strontium and zirconium were tested by E-Analytics Laboratory. The objective of this paper is to analyze flowback water quality from two horizontal wells, located in the same place, which were injected with two different fracturing fluids. Based on the results of the temporal quality trend, this paper also intends to analyze the impact of different pH on water quality and the possible chemical reactions that occur during drilling and fracturing phases."],"dc:format.medium":["born digital","masters theses"],"dc:identifier":["Jiang_X_colostate_0053N_12009.pdf","ETDF2013500386CVEE"],"dc:identifier.uri":["http://hdl.handle.net/10217/81030","https://doi.org/10.25675/3.020361"],"dc:language":["English"],"dc:language.iso":["eng"],"dc:publisher":["Colorado State University. Libraries"],"dc:relation":["wwdl"],"dc:relation.ispartof":["2000-2019"],"dc:rights":["Copyright and other restrictions may apply. User is responsible for compliance with all applicable laws. For information about copyright law, please see https://libguides.colostate.edu/copyright.","This Item is protected by copyright and/or related rights (https://rightsstatements.org/vocab/InC/1.0/). You are free to use this Item in any way that is permitted by the copyright and related rights legislation that applies to your use. For other uses you need to obtain permission from the rights-holder(s)."],"dc:subject":["Wattenberg field","flowback water","water quality","fracturing fluid"],"dc:title":["Flowback quality characterization for horizontal wells in Wattenberg field"],"dc:type":["Text"],"others:access_status":["open.access"],"thesis:degree_discipline":["Civil and Environmental Engineering"],"thesis:degree_level":["Masters"],"thesis:degree_name":["Master of Science (M.S.)"],"thesis:institution_name":["Colorado State University"]},"updated_at":"2026-11-19T07:10:57Z"}