{"id":{"repo_id":"colostate","oai_identifier":"oai:mountainscholar.org:10217/83745"},"canonical_url":"https://search.ndltd.org/etd/colostate/oai:mountainscholar.org:10217/83745","repository":{"repo_id":"colostate","name":"Colorado State University","base_url":"https://api.mountainscholar.org/server/oai/request"},"display":{"title":"Design, simulation, and prototyping of wavelength-shifting plate light collector for a large water Cherenkov detector","abstract":"A wavelength-shifting plate light collector has been investigated for a proposed water Cherenkov detector for the Long-Baseline Neutrino Experiment. Experimental prototypes were fabricated from four different wavelength-shifting plastics and tested under uniform illumination as well as with a point source scanner. These laboratory tests were used to study the wavelength and position dependence of the plate's light collection. These results were then used to develop an optical model for the plates that was then used to estimate their effect on measuring neutrino events in the full water Cherenkov detector simulation. These results showed that it was possible to guide between 34% and 49% extra light to a 12\" hemispherical PMT. In addition the plates were not found to adversely affect the particle identification abilities of the detector.","abstract_html":"A wavelength-shifting plate light collector has been investigated for a proposed water Cherenkov detector for the Long-Baseline Neutrino Experiment. Experimental prototypes were fabricated from four different wavelength-shifting plastics and tested under uniform illumination as well as with a point source scanner. These laboratory tests were used to study the wavelength and position dependence of the plate&#x27;s light collection. These results were then used to develop an optical model for the plates that was then used to estimate their effect on measuring neutrino events in the full water Cherenkov detector simulation. These results showed that it was possible to guide between 34% and 49% extra light to a 12&quot; hemispherical PMT. In addition the plates were not found to adversely affect the particle identification abilities of the detector.","abstract_has_math":false,"creators":["Johnston, William Albert, author","Buchanan, Norm, advisor","Wilson, Robert J., committee member","Sites, James, committee member","Menoni, Carmen, committee member"],"institution":"Colorado State University. Libraries","degree_name":"Doctor of Philosophy (Ph.D.)","degree_level":"Doctoral","degree_discipline":"Physics","degree_department":null,"school":null,"contributors":[],"advisors":[],"committee_chairs":[],"committee_members":[],"year":2014,"date_issued":"2014","date_published":"2014","updated_at":"2026-11-19T07:10:12Z","subjects":["fluorescent plastic","light collector","non-focusing optics","photomultiplier tube","PMT","wavelength shifting plate"],"languages":["eng","English"],"rights":["Copyright and other restrictions may apply. User is responsible for compliance with all applicable laws. For information about copyright law, please see https://libguides.colostate.edu/copyright.","This Item is protected by copyright and/or related rights (https://rightsstatements.org/vocab/InC/1.0/). You are free to use this Item in any way that is permitted by the copyright and related rights legislation that applies to your use. For other uses you need to obtain permission from the rights-holder(s)."],"rights_urls":[],"identifier_entries":[{"key":"dc:identifier.uri","label":"Identifier URI","values":["http://hdl.handle.net/10217/83745"],"render_values":[{"text":"http://hdl.handle.net/10217/83745","href":"https://hdl.handle.net/10217/83745","code":true}]},{"key":"dc:identifier","label":"Identifier","values":["Johnston_colostate_0053A_12524.pdf"],"render_values":[{"text":"Johnston_colostate_0053A_12524.pdf","href":null,"code":true}]}],"person_identifier_entries":[]},"links":{"outbound_url":"https://doi.org/10.25675/3.019610","outbound_label":"DOI","outbound_source":"dc:identifier.uri","record_url":"https://doi.org/10.25675/3.019610","record_label":"Repository record","record_kind":"doi","record_source":"dc:identifier.uri","access_status":null,"embargo_until":null,"access_note":null},"oai_pmh_record":{"url":"https://union.ndltd.org/oai-pmh/?verb=GetRecord&metadataPrefix=oai_dc&identifier=oai%3Aunion.ndltd.org%3Arepo%3Acolostate%3Aoai%3Amountainscholar.org%3A10217%2F83745","prefix":"oai_dc"},"source_record":{"url":"https://api.mountainscholar.org/server/oai/request?verb=GetRecord&metadataPrefix=dim&identifier=oai%3Amountainscholar.org%3A10217%2F83745","prefix":"dim"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:creator","label":"Author","values":["Johnston, William Albert, author","Buchanan, Norm, advisor","Wilson, Robert J., committee member","Sites, James, committee member","Menoni, Carmen, committee member"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2007-01-03T06:31:33Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2007-01-03T06:31:33Z"]},{"key":"dc:date.issued","label":"Date","values":["2014"]},{"key":"dc:publisher","label":"Institution","values":["Colorado State University. Libraries"]},{"key":"dc:relation.ispartof","label":"Dc Relation Ispartof","values":["2000-2019"]},{"key":"dc:type","label":"Dc Type","values":["Text"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Physics"]},{"key":"thesis:degree_level","label":"Degree Level","values":["Doctoral"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Doctor of Philosophy (Ph.D.)"]},{"key":"thesis:institution_name","label":"Thesis Institution Name","values":["Colorado State University"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["fluorescent plastic","light collector","non-focusing optics","photomultiplier tube","PMT","wavelength shifting plate"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language","label":"Dc Language","values":["English"]},{"key":"dc:language.iso","label":"Language (ISO)","values":["eng"]},{"key":"dc:rights","label":"Dc Rights","values":["Copyright and other restrictions may apply. User is responsible for compliance with all applicable laws. For information about copyright law, please see https://libguides.colostate.edu/copyright.","This Item is protected by copyright and/or related rights (https://rightsstatements.org/vocab/InC/1.0/). You are free to use this Item in any way that is permitted by the copyright and related rights legislation that applies to your use. For other uses you need to obtain permission from the rights-holder(s)."]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier","label":"Identifier","values":["Johnston_colostate_0053A_12524.pdf"]},{"key":"dc:identifier.uri","label":"Identifier URI","values":["http://hdl.handle.net/10217/83745","https://doi.org/10.25675/3.019610"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["A wavelength-shifting plate light collector has been investigated for a proposed water Cherenkov detector for the Long-Baseline Neutrino Experiment. Experimental prototypes were fabricated from four different wavelength-shifting plastics and tested under uniform illumination as well as with a point source scanner. These laboratory tests were used to study the wavelength and position dependence of the plate's light collection. These results were then used to develop an optical model for the plates that was then used to estimate their effect on measuring neutrino events in the full water Cherenkov detector simulation. These results showed that it was possible to guide between 34% and 49% extra light to a 12\" hemispherical PMT. In addition the plates were not found to adversely affect the particle identification abilities of the detector."]},{"key":"dc:format.medium","label":"Dc Format Medium","values":["born digital","doctoral dissertations"]},{"key":"dc:title","label":"Title","values":["Design, simulation, and prototyping of wavelength-shifting plate light collector for a large water Cherenkov detector"]},{"key":"others:access_status","label":"Others Access Status","values":["open.access"]}]}],"canonical_facts":{"dc:creator":["Johnston, William Albert, author","Buchanan, Norm, advisor","Wilson, Robert J., committee member","Sites, James, committee member","Menoni, Carmen, committee member"],"dc:date.accessioned":["2007-01-03T06:31:33Z"],"dc:date.available":["2007-01-03T06:31:33Z"],"dc:date.issued":["2014"],"dc:description.abstract":["A wavelength-shifting plate light collector has been investigated for a proposed water Cherenkov detector for the Long-Baseline Neutrino Experiment. Experimental prototypes were fabricated from four different wavelength-shifting plastics and tested under uniform illumination as well as with a point source scanner. These laboratory tests were used to study the wavelength and position dependence of the plate's light collection. These results were then used to develop an optical model for the plates that was then used to estimate their effect on measuring neutrino events in the full water Cherenkov detector simulation. These results showed that it was possible to guide between 34% and 49% extra light to a 12\" hemispherical PMT. In addition the plates were not found to adversely affect the particle identification abilities of the detector."],"dc:format.medium":["born digital","doctoral dissertations"],"dc:identifier":["Johnston_colostate_0053A_12524.pdf"],"dc:identifier.uri":["http://hdl.handle.net/10217/83745","https://doi.org/10.25675/3.019610"],"dc:language":["English"],"dc:language.iso":["eng"],"dc:publisher":["Colorado State University. Libraries"],"dc:relation.ispartof":["2000-2019"],"dc:rights":["Copyright and other restrictions may apply. User is responsible for compliance with all applicable laws. For information about copyright law, please see https://libguides.colostate.edu/copyright.","This Item is protected by copyright and/or related rights (https://rightsstatements.org/vocab/InC/1.0/). You are free to use this Item in any way that is permitted by the copyright and related rights legislation that applies to your use. For other uses you need to obtain permission from the rights-holder(s)."],"dc:subject":["fluorescent plastic","light collector","non-focusing optics","photomultiplier tube","PMT","wavelength shifting plate"],"dc:title":["Design, simulation, and prototyping of wavelength-shifting plate light collector for a large water Cherenkov detector"],"dc:type":["Text"],"others:access_status":["open.access"],"thesis:degree_discipline":["Physics"],"thesis:degree_level":["Doctoral"],"thesis:degree_name":["Doctor of Philosophy (Ph.D.)"],"thesis:institution_name":["Colorado State University"]},"updated_at":"2026-11-19T07:10:12Z"}