{"id":{"repo_id":"colostate","oai_identifier":"oai:mountainscholar.org:10217/83826"},"canonical_url":"https://search.ndltd.org/etd/colostate/oai:mountainscholar.org:10217/83826","repository":{"repo_id":"colostate","name":"Colorado State University","base_url":"https://api.mountainscholar.org/server/oai/request"},"display":{"title":"Advances in single-pixel imaging toward biological applications","abstract":"In this work, we discuss two new methods for single-pixel imaging. First, we leverage advances in laser metrology and frequency synthesis to measure small shifts in the center frequency of an optical pulse. Pulses acquire such shifts when probing a transient optical susceptibility, as in impulsive stimulated Raman scattering, which we use to demonstrate the technique. We analyze the limits of this technique with regard to fundamental noise, and predict detection sensitivity in these limiting cases. We then present work on imaging in two dimensions, both x-y and x-z, using single element detectors. We accomplish this by multiplexing spatial frequency projections in time, allowing rapid two dimensional imaging without an imaging detector. As we eliminate the imaging detector, the sensitivity to scattering is dramatically decreased, allowing the method to be used deep in scattering tissue. Results are shown for several geometries and experimental configurations, demonstrating imaging capabilities across a variety of sample types, including fluorescent and biological samples.","abstract_html":"In this work, we discuss two new methods for single-pixel imaging. First, we leverage advances in laser metrology and frequency synthesis to measure small shifts in the center frequency of an optical pulse. Pulses acquire such shifts when probing a transient optical susceptibility, as in impulsive stimulated Raman scattering, which we use to demonstrate the technique. We analyze the limits of this technique with regard to fundamental noise, and predict detection sensitivity in these limiting cases. We then present work on imaging in two dimensions, both x-y and x-z, using single element detectors. We accomplish this by multiplexing spatial frequency projections in time, allowing rapid two dimensional imaging without an imaging detector. As we eliminate the imaging detector, the sensitivity to scattering is dramatically decreased, allowing the method to be used deep in scattering tissue. Results are shown for several geometries and experimental configurations, demonstrating imaging capabilities across a variety of sample types, including fluorescent and biological samples.","abstract_has_math":false,"creators":["Winters, David G., author","Bartels, Randy, advisor","Marconi, Mario C., committee member","Prasad, Ashok, committee member","Bernstein, Elliot R., committee member"],"institution":"Colorado State University. Libraries","degree_name":"Doctor of Philosophy (Ph.D.)","degree_level":"Doctoral","degree_discipline":"Electrical and Computer Engineering","degree_department":null,"school":null,"contributors":[],"advisors":[],"committee_chairs":[],"committee_members":[],"year":2014,"date_issued":"2014","date_published":"2014","updated_at":"2026-11-19T07:10:09Z","subjects":[],"languages":["eng","English"],"rights":["Copyright and other restrictions may apply. User is responsible for compliance with all applicable laws. For information about copyright law, please see https://libguides.colostate.edu/copyright.","This Item is protected by copyright and/or related rights (https://rightsstatements.org/vocab/InC/1.0/). You are free to use this Item in any way that is permitted by the copyright and related rights legislation that applies to your use. For other uses you need to obtain permission from the rights-holder(s)."],"rights_urls":[],"identifier_entries":[{"key":"dc:identifier.uri","label":"Identifier URI","values":["http://hdl.handle.net/10217/83826"],"render_values":[{"text":"http://hdl.handle.net/10217/83826","href":"https://hdl.handle.net/10217/83826","code":true}]},{"key":"dc:identifier","label":"Identifier","values":["Winters_colostate_0053A_12529.pdf"],"render_values":[{"text":"Winters_colostate_0053A_12529.pdf","href":null,"code":true}]}],"person_identifier_entries":[]},"links":{"outbound_url":"https://doi.org/10.25675/3.019546","outbound_label":"DOI","outbound_source":"dc:identifier.uri","record_url":"https://doi.org/10.25675/3.019546","record_label":"Repository record","record_kind":"doi","record_source":"dc:identifier.uri","access_status":"embargoed","embargo_until":"2015-09-30","access_note":null},"oai_pmh_record":{"url":"https://union.ndltd.org/oai-pmh/?verb=GetRecord&metadataPrefix=oai_dc&identifier=oai%3Aunion.ndltd.org%3Arepo%3Acolostate%3Aoai%3Amountainscholar.org%3A10217%2F83826","prefix":"oai_dc"},"source_record":{"url":"https://api.mountainscholar.org/server/oai/request?verb=GetRecord&metadataPrefix=dim&identifier=oai%3Amountainscholar.org%3A10217%2F83826","prefix":"dim"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:creator","label":"Author","values":["Winters, David G., author","Bartels, Randy, advisor","Marconi, Mario C., committee member","Prasad, Ashok, committee member","Bernstein, Elliot R., committee member"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2007-01-03T06:35:24Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2015-09-30T06:30:24Z"]},{"key":"dc:date.embargo","label":"Dc Date Embargo","values":["2015-09-30"]},{"key":"dc:date.issued","label":"Date","values":["2014"]},{"key":"dc:date.liftdate","label":"Dc Date Liftdate","values":["2015-09-30"]},{"key":"dc:publisher","label":"Institution","values":["Colorado State University. Libraries"]},{"key":"dc:relation.ispartof","label":"Dc Relation Ispartof","values":["2000-2019"]},{"key":"dc:type","label":"Dc Type","values":["Text"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Electrical and Computer Engineering"]},{"key":"thesis:degree_level","label":"Degree Level","values":["Doctoral"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Doctor of Philosophy (Ph.D.)"]},{"key":"thesis:institution_name","label":"Thesis Institution Name","values":["Colorado State University"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language","label":"Dc Language","values":["English"]},{"key":"dc:language.iso","label":"Language (ISO)","values":["eng"]},{"key":"dc:rights","label":"Dc Rights","values":["Copyright and other restrictions may apply. User is responsible for compliance with all applicable laws. For information about copyright law, please see https://libguides.colostate.edu/copyright.","This Item is protected by copyright and/or related rights (https://rightsstatements.org/vocab/InC/1.0/). You are free to use this Item in any way that is permitted by the copyright and related rights legislation that applies to your use. For other uses you need to obtain permission from the rights-holder(s)."]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier","label":"Identifier","values":["Winters_colostate_0053A_12529.pdf"]},{"key":"dc:identifier.uri","label":"Identifier URI","values":["http://hdl.handle.net/10217/83826","https://doi.org/10.25675/3.019546"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["In this work, we discuss two new methods for single-pixel imaging. First, we leverage advances in laser metrology and frequency synthesis to measure small shifts in the center frequency of an optical pulse. Pulses acquire such shifts when probing a transient optical susceptibility, as in impulsive stimulated Raman scattering, which we use to demonstrate the technique. We analyze the limits of this technique with regard to fundamental noise, and predict detection sensitivity in these limiting cases. We then present work on imaging in two dimensions, both x-y and x-z, using single element detectors. We accomplish this by multiplexing spatial frequency projections in time, allowing rapid two dimensional imaging without an imaging detector. As we eliminate the imaging detector, the sensitivity to scattering is dramatically decreased, allowing the method to be used deep in scattering tissue. Results are shown for several geometries and experimental configurations, demonstrating imaging capabilities across a variety of sample types, including fluorescent and biological samples."]},{"key":"dc:format.medium","label":"Dc Format Medium","values":["born digital","doctoral dissertations"]},{"key":"dc:title","label":"Title","values":["Advances in single-pixel imaging toward biological applications"]},{"key":"others:access_status","label":"Others Access Status","values":["open.access"]}]}],"canonical_facts":{"dc:creator":["Winters, David G., author","Bartels, Randy, advisor","Marconi, Mario C., committee member","Prasad, Ashok, committee member","Bernstein, Elliot R., committee member"],"dc:date.accessioned":["2007-01-03T06:35:24Z"],"dc:date.available":["2015-09-30T06:30:24Z"],"dc:date.embargo":["2015-09-30"],"dc:date.issued":["2014"],"dc:date.liftdate":["2015-09-30"],"dc:description.abstract":["In this work, we discuss two new methods for single-pixel imaging. First, we leverage advances in laser metrology and frequency synthesis to measure small shifts in the center frequency of an optical pulse. Pulses acquire such shifts when probing a transient optical susceptibility, as in impulsive stimulated Raman scattering, which we use to demonstrate the technique. We analyze the limits of this technique with regard to fundamental noise, and predict detection sensitivity in these limiting cases. We then present work on imaging in two dimensions, both x-y and x-z, using single element detectors. We accomplish this by multiplexing spatial frequency projections in time, allowing rapid two dimensional imaging without an imaging detector. As we eliminate the imaging detector, the sensitivity to scattering is dramatically decreased, allowing the method to be used deep in scattering tissue. Results are shown for several geometries and experimental configurations, demonstrating imaging capabilities across a variety of sample types, including fluorescent and biological samples."],"dc:format.medium":["born digital","doctoral dissertations"],"dc:identifier":["Winters_colostate_0053A_12529.pdf"],"dc:identifier.uri":["http://hdl.handle.net/10217/83826","https://doi.org/10.25675/3.019546"],"dc:language":["English"],"dc:language.iso":["eng"],"dc:publisher":["Colorado State University. Libraries"],"dc:relation.ispartof":["2000-2019"],"dc:rights":["Copyright and other restrictions may apply. User is responsible for compliance with all applicable laws. For information about copyright law, please see https://libguides.colostate.edu/copyright.","This Item is protected by copyright and/or related rights (https://rightsstatements.org/vocab/InC/1.0/). You are free to use this Item in any way that is permitted by the copyright and related rights legislation that applies to your use. For other uses you need to obtain permission from the rights-holder(s)."],"dc:title":["Advances in single-pixel imaging toward biological applications"],"dc:type":["Text"],"others:access_status":["open.access"],"thesis:degree_discipline":["Electrical and Computer Engineering"],"thesis:degree_level":["Doctoral"],"thesis:degree_name":["Doctor of Philosophy (Ph.D.)"],"thesis:institution_name":["Colorado State University"]},"updated_at":"2026-11-19T07:10:09Z"}